Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Eng Technol ; 14(3): 447-456, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36971975

RESUMO

PURPOSE: Knowledge of the timing of cardiac valve opening and closing is important in cardiac physiology. The relationship between valve motion and electrocardiogram (ECG) is often assumed, however is not clearly defined. Here we investigate the accuracy of cardiac valve timing estimated using only the ECG, compared to Doppler echocardiography (DE) flow imaging as the gold standard. METHODS: DE was obtained in 37 patients with simultaneous ECG recording. ECG was digitally processed and identifiable features (QRS, T, P waves) were examined as potential reference points to determine opening and closure of aortic and mitral valves, as compared to DE outflow and inflow measurement. Timing offset of the cardiac valves opening and closure between ECG features and DE was measured from derivation set (n = 19). The obtained mean offset in combination with the ECG features model was then evaluated on a validation set (n = 18). Using the same approach, additional measurement was also done for the right sided valves. RESULTS: From the derivation set, we found a fixed offset of 22 ± 9 ms, 2 ± 13 ms, 90 ± 26 ms, and - 2 ± - 27 ms when comparing S to aortic valve opening, Tend to aortic valve closure, Tend to mitral valve opening, and R to mitral valve closure respectively. Application of this model to the validation set showed good estimation of aortic and mitral valve opening and closure timing value, with low model absolute error (median of the mean absolute error of the four events = 19 ms compared to the gold standard DE measurement). For the right-sided (tricuspid and pulmonic) valves in our patient set, there was considerably higher median of the mean absolute error of 42 ms for the model. CONCLUSION: ECG features can be used to estimate aortic and mitral valve timings with good accuracy as compared to DE, allowing useful hemodynamic information to be derived from this easily available test.


Assuntos
Valva Aórtica , Valva Pulmonar , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiologia , Eletrocardiografia/métodos , Valva Mitral/diagnóstico por imagem , Hemodinâmica
2.
Radiol Case Rep ; 17(1): 259-264, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34849181

RESUMO

Constrictive pericarditis is a rare cause of right-sided heart failure secondary to a stiff, non-compliant pericardium. Clinical presentation can vary considerably and requires a high suspicion for diagnosis. A 31-year-old male presented to the emergency department with complaints of abdominal distension. An abdominal ultrasound revealed large volume ascites; thus, it was initially suspected he had underlying cirrhosis. However, an echocardiogram revealed a diagnosis of constrictive pericarditis. It's important for clinicians to consider constrictive pericarditis in a patient presenting with unexplained right-sided heart failure.

3.
World J Cardiol ; 12(8): 427-436, 2020 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-32879705

RESUMO

BACKGROUND: Treatment of congenitally corrected transposition of great arteries (cc-TGA) with anatomic repair strategy has been considered superior due to restoration of the morphologic left ventricle in the systemic circulation. However, data on long term outcomes are limited to single center reports and include small sample sizes. AIM: To perform a systematic review and meta-analysis for observational studies reporting outcomes on anatomic repair for cc-TGA. METHODS: MEDLINE and Scopus databases were queried using predefined criteria for reports published till December 31, 2017. Studies reporting anatomic repair of minimum 5 cc-TGA patients with at least a 2 year follow up were included. Meta-analysis was performed using Comprehensive meta-analysis v3.0 software. RESULTS: Eight hundred and ninety-five patients underwent anatomic repair with a pooled follow-up of 5457.2 patient-years (PY). Pooled estimate for operative mortality was 8.3% [95% confidence interval (CI): 6.0%-11.4%]. 0.2% (CI: 0.1%-0.4%) patients required mechanical circulatory support postoperatively and 1.7% (CI: 1.1%-2.4%) developed post-operative atrioventricular block requiring a pacemaker. Patients surviving initial surgery had a transplant free survival of 92.5% (CI: 89.5%-95.4%) per 100 PY and a low rate of need for pacemaker (0.3/100 PY; CI: 0.1-0.4). 84.7% patients (CI: 79.6%-89.9%) were found to be in New York Heart Association (NYHA) functional class I or II after 100 PY follow up. Total re-intervention rate was 5.3 per 100 PY (CI: 3.8-6.8). CONCLUSION: Operative mortality with anatomic repair strategy for cc-TGA is high. Despite that, transplant free survival after anatomic repair for cc-TGA patients is highly favorable. Majority of patients maintain NYHA I/II functional class. However, monitoring for burden of re-interventions specific for operation type is very essential.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...