Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Ther ; 75(2): 119-32, 1995 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7846132

RESUMO

BACKGROUND AND PURPOSE: In this study, we examined changes in kinematic and electromyographic (EMG) measurements of the coordination (ie, the relative timing of joint movements and muscle activity) of a squat-lifting task in response to lifting increasing loads. SUBJECTS: Fifteen male industrial workers served as a sample of convenience. METHODS: Subjects lifted a weighted crate containing 15% to 75% of their maximum lifting capacity using a symmetrical squat-lift technique. Movement kinematics were obtained with videography. The relative phase between joint motions was derived. The EMG activity of the vastus lateralis muscle (VL) and the erector spinae muscle (ES) was recorded, and the relative timing of their onsets and peaks was estimated. RESULTS: The relative phase of movement between joints such as the knee and lumbar spine changed in a quasi-linear fashion with increasing load during lifting but not during lowering. The relative time of onset of ES EMG activity and its peak activity changed in a manner consistent with the interjoint relative phase results. The timing of VL events were not affected by increasing the load. CONCLUSION AND DISCUSSION: Relatively continuous changes in interlimb coordination occur when increasing the load lifted from an initial squatting posture. Changes in EMG relative timing partially corroborate the kinematic evidence for changes in coordination with load scaling. The results indicate the need for further study to determine whether the observed changes in coordination are beneficial or detrimental to the musculoskeletal system. Clinicians should evaluate performance of this task under a range of task conditions.


Assuntos
Articulações/fisiologia , Remoção , Atividade Motora/fisiologia , Músculo Esquelético/fisiologia , Adulto , Análise de Variância , Fenômenos Biomecânicos , Eletromiografia , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/inervação , Postura , Valores de Referência , Gravação em Vídeo , Suporte de Carga/fisiologia
2.
J Mot Behav ; 25(1): 2-7, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12730036

RESUMO

This study evaluated the accuracy and precision of the PEAK Performance Technologies, lnc.'s motion analysis system for three-dimensional angle reconstruction. Pendular motion of a bar, on which 18 retroreflective markers were mounted, was videotaped at three different orientations (parallel, and rotated 30 degrees right and left) to a plane at which two standard video cameras were aimed. The videotaped motion was digitized off-line, and 32 angles between the 18 markers were calculated. intraclass correlation coefficients (ICCs) were calculated between trials within each pendulum orientation and across orientations to determine system precision, and between randomly selected trials and actual angles to determine accuracy. lCCs were in all cases greater than.99. Within-trial standard deviations ranged between 0.05-0.8 degrees for the different angles. Deviations from the actual angle averaged 0.0-0.8 degrees across all angles and orientations. The results indicate that accurate and reliable angular measurements can be made with this motion analysis system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...