1.
Arthroplast Today ; 27: 101401, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38812475

RESUMO

A 68-year-old man was referred due to bilateral hip pain and gradual deterioration of walking. He had mold arthroplasties on both hips at the age of 7 years and has been functioning well for more than 5 decades. However, the original data on operative report and the prostheses were missing. The radiological examination revealed bilateral broken prosthetic material. Thus, stage bilateral revision total hip arthroplasty was performed. A detailed chemical analysis of retrieved mold arthroplasty implants proved that the acrylic material was noted to be the same composition with the difference in appearance likely being related to different thermal treatments originally applied to the implants. As presented in our clinical case, even obsolete implants may have good survivorship. According to the case presented, total hip arthroplasty could be considered an effective option with the desired functional outcome when conservative and joint-preserving measures are exhausted.

2.
Gels ; 10(5)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38786211

RESUMO

In recent research, significant interest has been directed towards gelatin-based hydrogels due to their affordable price, extensive availability, and biocompatibility, making them promising candidates for various biomedical applications. The development and characterization of novel hydrogels formed from varying ratios of gelatin, triblock copolymer Pluronic F-127, and phytic acid have been presented. Swelling properties were examined at different pH levels. The morphology of hydrogels and their thermal properties were analyzed using scanning electron microscopy (SEM), thermogravimetric analysis (TG), and differential scanning calorimetry (DSC). Fourier-transform infrared (FTIR) analysis of the hydrogels was also performed. The introduction of phytic acid in the hydrogel plays a crucial role in enhancing the intermolecular interactions within gelatin-based hydrogels, contributing to a more stable, elastic, and robust network structure.

3.
Heliyon ; 10(4): e26024, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38420464

RESUMO

This research focuses on the surface modification of Nd-Fe-B magnetic powder to enhance its thermal and oxidation resistance without compromising magnetic properties and to improve adhesion to the polymer binder for enhanced mechanical properties. A three-step surface modification process involving phosphatization treatment, tetraethyl orthosilicate (TEOS) application, and 3-aminopropyltriethoxysilane (APTES) grafting, was applied to the powder, which was then compounded with polyamide 12 and injection-moulded into cylinders and dog-bone-shaped tubes. The resulting magnets exhibited remanence (Br) of 487.6 mT, coercivity (Hci) of 727.7 kA/m, and energy product (BHmax) of 39.3 kJ/m3. The modified magnets demonstrated exceptional corrosion resistance and thermal stability, with less than 5% irreversible flux loss after exposure to hot water, temperature shock, and pressurised steam. Furthermore, the modified magnets displayed significantly higher tensile strength, elongation at break, and elastic modulus with improvements of 62%, 16.7%, and 19.9%, respectively, compared to the non-modified batch. Additionally, the modified batch showed a notable 52% increase in flexural stress during flexural testing. These findings underscore the potential of silane surface modifications in producing injection-moulded permanent magnets based on Nd-Fe-B alloy, extending their shelf life and enhancing their overall performance.

4.
Polymers (Basel) ; 15(19)2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37836042

RESUMO

This study presented a novel corrosion protective coating based on polyacrylic/siloxane-silica (PEHA-SS) deposited on lightweight cast aluminium alloy AlSi7Mg0.3. The synthesis of PEHA-SS comprises organic monomer 2-ethylhexyl acrylate and organically modified silane 3-(trimethoxysilyl)propyl methacrylate as well as an inorganic silane, tetraethyl orthosilicate. The steps during the synthesis process were monitored using real-time infrared spectroscopy. The coating deposited onto the AlSi7Mg0.3 surface was characterised using various techniques, including infrared spectroscopy, 3D contact profilometry, and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy. The corrosion resistance of the coated alloy in sodium chloride solutions was evaluated using electrochemical impedance spectroscopy. The accelerated testing of the uncoated and coated sample was performed using the Machu test. This novel, nine micrometres thick PEHA-SS coating achieved durable corrosion (barrier) protection for the AlSi7Mg0.3 alloy in 0.1 M NaCl during the first four months of immersion or under accelerated corrosion conditions in a Machu chamber containing NaCl, acetic acid, and hydrogen peroxide at 37 °C.

5.
Arch Orthop Trauma Surg ; 143(10): 6021-6031, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36928503

RESUMO

INTRODUCTION: The main aim was to analyse the series of 29 collected cemented Charnley-Muller Alivium retrievals with the meantime in situ of 27 years. In addition, the revision rate of 1425 Alivium prostheses implanted at our institution between 1977 and 1992 was calculated. MATERIALS AND METHODS: The revision percentage of the Alivium cohort was calculated up to 45 years of follow-up and compared to that of all total hip arthroplasties (THAs) implanted in the same period (No. 5535). Metal and polyethylene retrieved components were inspected in 29 cases for wear damage and roughness. Wear particles were retrieved from periprosthetic tissue using digestion protocols and their composition, morphology, and size distribution were investigated. Periprosthetic tissue was analysed histologically. RESULTS: The revision percentage of the Alivium cohort was 16% at 45 years of follow-up. It was comparable to all the THAs implanted at the same time (18%). The shape of polyethylene particles isolated from periprosthetic tissue corresponded to the wear pattern on polyethylene cups. Polyethylene particles were the main wear product, with the majority (68%) of particles smaller than 0.1 µm. Metal particles were rare with two types: CoCr and Cr based. Histological analysis showed that in 14 out of 18 specimens, the metal particles were graded + 1, reflecting that the metal loading in the periprosthetic tissue was low. CONCLUSIONS: Our study represents valuable data not reported previously on the survival rate of Charnley-Muller prostheses at 45 years of follow-up and a unique insight into the collected retrievals from the materials' point of view.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Corrosão , Falha de Prótese , Polietileno , Metais , Desenho de Prótese
6.
Molecules ; 27(3)2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35164365

RESUMO

A facile environmentally acceptable surface roughening method using chemical etching in HCl/H2O2 followed by grafting with n-octyltrimethoxysilane (AS-8) and 1H,1H,2H,2H-perfluorooctyltrimethoxysilane (FAS-8) was studied to fabricate a (super)hydrophobic aluminium surface. The ground aluminium surface after selected etching times (before and after grafting), was characterised using a contact profilometer, optical tensiometer, scanning electron microscope coupled with an energy-dispersive spectroscope and X-ray photoelectron spectroscope to evaluate surface roughness, wettability, surface morphology and composition. The durability of the grafted surface was tested using thermal and UV resistance tests. The corrosion properties were evaluated using potentiodynamic measurements and standard salts spray testing, ASTM B117-19. Finally, the self-cleaning and anti-icing abilities were assessed. The grafted aluminium surface with octyl- or perfluorooctyl silane reflected the highly hydrophobic (AS-8) and superhydrophobic behaviour (FAS-8). Moreover, the different behaviour of the octyl- or perfluorooctyl chain in the silane molecule on modified surface properties was also noticed because durability tests confirmed greater thermal, UV stability and corrosion resistance of FAS-8 compared to AS-8. The aluminium etched for 2 min and grafted with FAS-8 also demonstrated an excellent self-cleaning and anti-icing performance.

7.
Hip Int ; 32(1): 32-38, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33213223

RESUMO

BACKGROUND: Mixing and matching components from different manufacturers in total hip arthroplasty is a frequently used off-label praxis. The clinical consequences of this procedure have not been studied in detail. METHODS: 860 patients with matched and 1067 patients with mixed primary total hip replacement (THR) components carried out between 1 January 2002 and 31 December 2004, were selected from our Institution registry. The analysis endpoint was set at 1 January 2016. THRs with poorly performing components were excluded from study groups. Kaplan-Meier survival curves for both groups were calculated and compared using the Log-Rank test and the demographic data using the chi-square test. Correlations between demographic data and revisions were calculated using bivariate correlation. RESULTS: 28 revisions were carried out in the matched group and 67 in the mixed group. The 14-year overall survival probability was significantly better in the former (96.0%) than in the mixed group (92.7%) (p = 0.002). Survival, free of aseptic and septic failures, was statistically, significantly higher in the matched group (p = 0.026 and p = 0.007, respectively).The survival of the mixed subgroup with heads and stems from the same manufacturer did not differ statistically from that of the matched group (p = 0.079). CONCLUSIONS: In contrast to the results listed in the National Joint Registry and the New Zealand Joint Registry, the survival probability in our study was, statistically, significantly higher in total hip replacements using components of the same manufacturer. Importantly, mixing and matching the components of different manufacturers led to similar survival providing the head and the stem were from the same manufacturer.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Seguimentos , Humanos , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Reoperação , Taxa de Sobrevida
8.
J Orthop Case Rep ; 11(7): 45-48, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34790602

RESUMO

INTRODUCTION: Revisions due to the fracture of ceramic-on-ceramic (CoC) bearing are rare, however when they occur, they represent a major challenge to an orthopedic surgeon for ensuring safe and long-term survival of the replaced bearing. CASE REPORT: We present a case of fractured ceramic liner of total hip prosthesis that underwent revision to a metal-on-polyethylene (MoP) bearing couple, with consequent huge periprosthetic metallosis. Shortly after, the second revision operation followed using the third bearing couple of ceramic-on-polyethylene (CoP). At 10 years follow-up after the operation due to ceramic fracture, the patient is now pain free with full range of motion of the revised hip. CONCLUSION: Establishment of diagnostic routes and recommended protocols for CoC bearing fracture would allow easier recognition of potential fracture and diminish its consequences for the patients.

9.
Polymers (Basel) ; 12(4)2020 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-32325797

RESUMO

Pre-hydrolysed/condensed tetraethyl orthosilicate (TEOS) was added to a solution of methyl methacrylate (MMA) and 3-methacryloxypropyltrimethoxysilane (MAPTMS), and then copolymerised for various times to study the influence of the latter on the structure of hybrid sol-gel coatings as corrosion protection of aluminium alloy 7075-T6. The reactions taking place during preparation were characterised using real-time Fourier transform infrared spectroscopy, dynamic light scattering and gel permeation chromatography. The solution characteristics were evaluated, using viscosimetry, followed by measurements of thermal stability determined by thermogravimetric analysis. The optimal temperature for the condensation reaction was determined with the help of high-pressure differential scanning calorimetry. Once deposited on 7075-T6 substrates, the coatings were evaluated using a field emission scanning electron microscope coupled to an energy dispersive spectrometer to determine surface morphology, topography, composition and coating thickness. Corrosion properties were tested in dilute Harrison's solution (3.5 g/L (NH4)2SO4 and 0.5 g/L NaCl) using electrochemical impedance spectroscopy. The copolymerization of MMA and MAPTMS over 4 h was optimal for obtaining 1.4 µm thick coating with superior barrier protection against corrosion attack (Z10 mHz 1 GΩ cm2) during three months of exposure to the corrosive medium.

10.
Acta Chim Slov ; 66(3): 511-533, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33855529

RESUMO

Corrosion protection is an important global issue. Corrosion affects all metal materials in industry, infrastructure, civil engineering, transport, biomedicine, etc. causing their deterioration and degradation. Corrosion protection is a necessity which enables the safe and well-functioning of metal structures and devices. In addition to long-term efficiency, corrosion protection should be environmentally and economically acceptable. Growing population with needs on modern and high-tech technologies is boosting consumption of base and rare earth metals. All these issues are putting high demands on area of corrosion protection with the main goal to prolong the life-time of metal materials, reduce the need for steeply increasing production and thus preserve resources. In this review contemporary modes of corrosion protection of metal materials with the emphasis on copper and aluminium base alloys as one of most important base metals are presented. These include corrosion inhibitors, conversion, sol-gel and hydrophobic coatings. Examples are our research studies over the last decade are presented.

11.
J Biomed Mater Res B Appl Biomater ; 107(3): 858-867, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30102828

RESUMO

The titanium-aluminium (6 wt%)-vanadium (4 wt%) (Ti6Al4V) alloy is widely used as an orthopedic and dental implant material due to its high corrosion resistance in such environments. The corrosion resistance is usually determined by means of electrochemical methods, which may not be able to detect other chemical surface reactions. Literature findings report a synergistic effect of the combination of the abundant protein albumin and hydrogen peroxide (H2 O2 ) on the extent of metal release and corrosion of Ti6Al4V. The objectives of this study were to gain further mechanistic insight on the interplay of H2 O2 and albumin on the metal release process of Ti6Al4V with special focus on (1) kinetics and (2) H2 O2 and albumin concentrations. This was accomplished mainly by metal release and surface oxide composition investigations, which confirmed the combined effect of H2 O2 and albumin on the metal release process, although not detectable by electrochemical open circuit potential measurements. A concentration of 30 mM H2 O2 induced substantial changes in the surface oxide characteristics, an oxide which became thicker and enriched in aluminum. Bovine serum albumin (BSA) seemed to be able to deplete this aluminum content from the outermost surface or at least to delay its surface enrichment. This effect increased with increased BSA concentration, and for time periods longer than 24 h. This study hence suggests that short-term (accelerated) corrosion resistance measurements are not sufficient to predict potential health effects of Ti6Al4V alloys since also chemical dissolution mechanisms play a large role for metal release, possibly in a synergistic way. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 855-867, 2019.


Assuntos
Peróxido de Hidrogênio/química , Soroalbumina Bovina/química , Titânio/química , Ligas , Animais , Bovinos , Corrosão , Oxirredução
13.
Acta Orthop ; 89(2): 234-239, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29388497

RESUMO

Background and purpose - Despite the increasing number of total hip replacements (THRs), their systemic influence is still not known. We have studied the influence of specific features of THRs-the bearing surface, the use of bone cement and the material of the stem-on the cancer incidence. Patients and methods - In a retrospective cohort study we identified 8,343 patients with THRs performed at Valdoltra Hospital from September 1, 1997 to December 31, 2009. Patient data were linked to national cancer and population registries. The standardized incidence ratios (SIR) and Poisson regression relative risks (RR) were calculated for all and specific cancers. Results - General cancer risk in our cohort was comparable to the population risk. Comparing with population, the risk of prostate cancer was statistically significantly higher in patients with metal-on-metal bearings (SIR =1.35); with metal-on-polyethylene bearings (SIR =1.30), with non-cemented THRs (SIR =1.40), and with titanium alloy THRs (SIR =1.41). In these last 3 groups there was a lower risk of hematopoietic tumors (SIR =0.69; 0.66 and 0.66 respectively). Risk of kidney cancer was significantly higher in the non-metal-on-metal, non-cemented, and titanium alloy groups (SIR =1.30; 1.46 and 1.41 respectively). Risk of colorectal and lung cancer was significantly lower in the investigated cohort (SIR =0.82 and 0.83, respectively). Risk for all cancers combined as well as for prostate and skin cancer, shown by Poisson analysis, was higher in the metal-on-metal group compared with non-metal-on-metal group (RR =1.56; 2.02 and 1.92, respectively). Interpretation - Some associations were found between the THRs' features, especially a positive association between metal-on-metal bearings, and specific cancers.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Neoplasias/epidemiologia , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Neoplasias/patologia , Estudos Retrospectivos , Eslovênia
14.
J Biomed Mater Res B Appl Biomater ; 105(8): 2507-2515, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27661772

RESUMO

BACKGROUND: Due to degradation and metal dissolution during articulation of metal joint replacements the chemical periprosthetic environment may change. The aim was to establish whether metal replacements cause the local changes in pH and elevated metal concentrations. METHODS: pH was measured on samples from 167 patients: native hip and knee osteoarthritic joints, joints with hip and knee replacements revised for aseptic or septic reasons. pH of synovial fluid and periprosthetic tissue was measured perioperatively using a microelectrode and pH indicator papers for removed metal components. Metal concentrations were measured in 21 samples using inductively coupled plasma mass spectrometry. RESULTS: The mean pH value of synovial fluid at native osteoarthritic joints (n = 101) was 7.78 ± 0.38. The mean pH value of synovial fluid at revision aseptic operation (n = 58) was 7.60 ± 0.31, with statistically significant difference (p = 0.002) compared to native osteoarthritic joints. The mean pH value of synovial fluid at revision septic operation (n = 8) was 7.55 ± 0.25, with statistically significant difference (p = 0.038) compared to native osteoarthritic joints. Measurements in tissue and at stems were not reliable. In the majority of samples taken at revision increased levels of cobalt and chromium were measured. CONCLUSION: A small but statistically significant difference was observed in the pH of synovial fluid between natural joints with degenerative diseases and joints treated with metal replacements. Based on the increased metal levels we expected the value of pH to be lower, but the influence of metal ions is counteracted by the buffering capacity of human body. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2507-2515, 2017.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese de Quadril , Prótese do Joelho , Osteoartrite do Quadril/metabolismo , Osteoartrite do Joelho/metabolismo , Líquido Sinovial/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Osteoartrite do Joelho/cirurgia
15.
Acta Chim Slov ; 63(3): 544-59, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27640381

RESUMO

We report on the combined experimental and computational study of imidazole- and benzimidazole-based corrosion inhibitors containing methyl and/or mercapto groups. Electrochemical measurements and long-term immersion tests were performed on iron in NaCl solution, whilst computational study explicitly addresses the molecular level details of the bonding on iron surface by means of density functional theory calculations (DFT). Experimental data were the basis for the determination of inhibition efficiency and mechanism. Methyl group combined with mercapto group has a beneficial effect on corrosion inhibition at all inhibitor concentrations. The beneficial effect of mercapto group combined with benzene group is not so pronounced as when combined with methyl group. The latter is in stark contrast with the behaviour found previously on copper, where the effect of methyl group was detrimental and that of mercapto and benzene beneficial. Explicit DFT calculations reveal that methyl-group has a small effect on the inhibitor-surface interaction. In contrast, the presence of mercapto group involves the strong S-surface bonding and consequently the adsorption of inhibitors with mercapto group is found to be more exothermic.

16.
Hip Int ; 26(3): 237-43, 2016 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-27102552

RESUMO

PURPOSE: The purpose of this study was to compare the results of revision total hip arthroplasty after fracture of primary ceramic components using different type of revision bearing surfaces. METHODS: We analysed the results of 16 patients with a follow-up more than 3 years after first revision. 6 were revised to ceramic-on-ceramic (CoC) bearing, 9 to metal-on-polyethylene (MoP) and 1 to ceramic-on-cross-linked polyethylene (CoXLP) bearing. RESULTS: The mean follow-up was 87 months. Patients with revision to CoC had higher Harris Hip Score (HHS) of 89 points in comparison to the patients with revision to MoP with 84 points. Radiographic examinations revealed visible eccentric polyethylene wear with osteolysis in 3 out of 9 patients revised to MoP. There were no detrimental x-ray changes in patients revised to CoC components. CONCLUSIONS: We consider CoC as the best option at revision operation for ceramic component fracture.


Assuntos
Óxido de Alumínio/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril , Fraturas Periprotéticas/cirurgia , Reoperação/métodos , Idoso , Artroplastia de Quadril/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/diagnóstico por imagem , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Resultado do Tratamento , Suporte de Carga
17.
Mater Sci Eng C Mater Biol Appl ; 62: 458-66, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26952447

RESUMO

The paper is focused on elaboration of ZrO2 films on pure zirconium via anodizing in phosphoric acid with and without fluoride at constant potentials of 30 V and 60 V. The structure and composition of the films were investigated using scanning electronic microscopy, Raman spectroscopy and X-ray photoelectron spectroscopy. The composition of the oxides formed at both potentials can be identified as monoclinic ZrO2. In addition to Zr and O, the layers formed in phosphoric acid contain phosphorus originating from the phosphoric acid. When the phosphoric acid solution contains NaF, fluorine is also incorporated into the oxide layer. The oxides formed at a higher voltage have greater roughness than those formed at 30 V. Anodized samples exhibit smaller current densities during anodic polarization compared to the as-received zirconium covered with native oxide.


Assuntos
Técnicas Eletroquímicas , Saliva Artificial/química , Zircônio/química , Propriedades de Superfície
18.
J Mech Behav Biomed Mater ; 34: 243-52, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24608233

RESUMO

BACKGROUND AND PURPOSE: Metal-on-metal (MoM) bearings were introduced as an alternative to conventional metal-on-polyethylene (MoP) bearings to reduce the wear and to increase the survival of hip prostheses. The goal of the present study was to compare tribological properties and to evaluate periprosthetic tissue reaction in two identical groups of prostheses differing only in the type of bearings. PATIENTS AND METHODS: At revision operations 26 MoM and 12 MoP bearing components and perisprosthetic tissue samples were collected. Prosthetic components were used to assess wear damage, linear and volumetric wear and roughness. Periprosthetic tissue samples were used for histological as well as immunohistochemical analysis and isolation and characterization of wear particles. RESULTS: The mean linear wear rate in the MoM group was 2.34 (SD 1.93)µm/year, significantly lower than the value in the MoP group, 11.52 (SD 7.82)µm/year. Significantly lower was also the volumetric wear, 0.19 (SD 0.32)mm(3)/year for MoM compared to 0.98 (SD 0.78)mm(3)/year for MoP. In both groups the main wear mode was abrasive wear. Histological results for MoM group indicate more lymphocyte dominated periprosthetic tissue reaction compared to MoP group. The mean size of polyethylene particles in the MoP group was 0.21 (SD 0.44)µm. In the MoM nanosized CoCrMo particles were identified. The characterization of metal particles was complex and required special attention in terms of instrumentation (field emission scanning electron microscopy in back-scattered mode); otherwise it was difficult to distinguish metal particles from other particles in the tissue. CONCLUSIONS: Despite a significantly lower wear and, consequently, smaller load of periprosthetic tissue with wear particles in the MoM group, the tissue reaction was similar, if not more intense than in the MoP group.


Assuntos
Artroplastia de Quadril , Fêmur/citologia , Prótese de Quadril , Teste de Materiais , Metais , Polietileno , Fêmur/cirurgia , Humanos , Falha de Prótese , Propriedades de Superfície
19.
J Mater Sci Mater Med ; 25(4): 1099-114, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24452270

RESUMO

Samples of the quaternary Ti-20Nb-10Zr-5Ta alloy were immersed in Hanks' simulated physiological solution and in minimum essential medium (MEM) for 25 days. Samples of Ti metal served as controls. During immersion, the concentration of ions dissolved in MEM was measured by inductively coupled plasma mass spectrometry, while at the end of the experiment the composition of the surface layers was analyzed by X-ray photoelectron spectroscopy, and their morphology by scanning electron microscopy equipped for chemical analysis. The surface layer formed during immersion was comprised primarily of TiO2 but contained oxides of alloying elements as well. The degree of oxidation differed for different metal cations; while titanium achieved the highest valency, tantalum remained as the metal or is oxidized to its sub-oxides. Calcium phosphate was formed in both solutions, while formation of organic-related species was observed only in MEM. Dissolution of titanium ions was similar for metal and alloy. Among alloying elements, zirconium dissolved in the largest quantity. The long-term effects of alloy implanted in the recipient's body were investigated in MEM, using two types of human cells-an osteoblast-like cell line and immortalized pulmonary fibroblasts. The in vitro biocompatibility of the quaternary alloy was similar to that of titanium, since no detrimental effects on cell survival, induction of apoptosis, delay of growth, or change in alkaline phosphatase activity were observed on incubation in MEM.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Nióbio/química , Tantálio/química , Titânio/química , Zircônio/química , Fosfatase Alcalina/metabolismo , Ligas/toxicidade , Apoptose/efeitos dos fármacos , Materiais Biocompatíveis/toxicidade , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Humanos , Soluções Isotônicas , Teste de Materiais , Nióbio/toxicidade , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Osteoblastos/enzimologia , Espectroscopia Fotoeletrônica , Solubilidade , Propriedades de Superfície , Tantálio/toxicidade , Titânio/toxicidade , Zircônio/toxicidade
20.
J Arthroplasty ; 29(1): 176-80, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23639386

RESUMO

We present a retrospective evaluation of 1369 hip arthroplasties performed using the Bicon-Plus cups and SL-Plus stems, differing only in the bearing combination. Four bearing combination groups were used: metal-on-polyethylene (MoP) group with 587 hips, ceramic-on-polyethylene (CoP) group with 161 hips, metal-on-metal (MoM) group with 322 hips and ceramic-on-ceramic (CoC) group with 299 hips. The mean follow-up was 11.5 years (4.1 to 15.0). Radiological evaluation was performed on implants failed due to aseptic loosening. The survival for prosthesis with revision for any reason at ten years was 96.1% (95% confidence interval (CI) 94.3 to 97.9) for MoP, 98.1% (CI 95.9 to 100) for CoP, 90.2% (CI 86.8 to 93.6) for MoM, and 95.6% (CI 93.0 to 98.2) for CoC. Survival for aseptic loosening was also determined.


Assuntos
Artroplastia de Quadril , Articulação do Quadril/cirurgia , Prótese de Quadril , Artropatias/cirurgia , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Materiais Biocompatíveis , Cerâmica , Feminino , Seguimentos , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Polietileno , Falha de Prótese , Estudos Retrospectivos , Resultado do Tratamento