Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Healthc Mater ; 12(27): e2301101, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37526266

RESUMO

Simplification of complex medication regimens in polypharmacy positively contributes to treatment adherence and cost-effective improved health outcomes. Even though fixed dose combination (FDC) drug products are the only currently available single dose poly-pill regimens, the lack of flexibility in dose adjustment of a single drug in the combination limits their efficacy. To fill the existing gap in drug dose personalization and simplification of complex medication regimens commonly encountered in the treatment of cardiovascular disease, tuberculosis, and tapering of corticosteroid therapy, a modular titratable polypill approach that simultaneously addresses both aspects is proposed. The polypill consists of modular units that contain different drugs at incremental or decremental doses to be assembled in a single titratable polypill at the required dose for each drug through a stacking or interlocking process. The variable dose (VD) modular tablets are subjected to quality control tests and found to comply to pharmacopeia's acceptance criteria and requirements specified in the respective drug monographs. A cost-effectiveness analysis is conducted supporting the VD strategy as cost-effective compared to the FDC strategy and more effective and less expensive than standard of care. The VD approach stands to enable pill burden reduction, ease of administration, enhancement of treatment adherence, and potential cost-saving benefits.


Assuntos
Doenças Cardiovasculares , Medicina de Precisão , Humanos , Combinação de Medicamentos , Doenças Cardiovasculares/tratamento farmacológico
2.
Sci Robot ; 8(77): eade9676, 2023 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-37099636

RESUMO

The gut-brain axis, which is mediated via enteric and central neurohormonal signaling, is known to regulate a broad set of physiological functions from feeding to emotional behavior. Various pharmaceuticals and surgical interventions, such as motility agents and bariatric surgery, are used to modulate this axis. Such approaches, however, are associated with off-target effects or post-procedure recovery time and expose patients to substantial risks. Electrical stimulation has also been used to attempt to modulate the gut-brain axis with greater spatial and temporal resolution. Electrical stimulation of the gastrointestinal (GI) tract, however, has generally required invasive intervention for electrode placement on serosal tissue. Stimulating mucosal tissue remains challenging because of the presence of gastric and intestinal fluid, which can influence the effectiveness of local luminal stimulation. Here, we report the development of a bioinspired ingestible fluid-wicking capsule for active stimulation and hormone modulation (FLASH) capable of rapidly wicking fluid and locally stimulating mucosal tissue, resulting in systemic modulation of an orexigenic GI hormone. Drawing inspiration from Moloch horridus, the "thorny devil" lizard with water-wicking skin, we developed a capsule surface capable of displacing fluid. We characterized the stimulation parameters for modulation of various GI hormones in a porcine model and applied these parameters to an ingestible capsule system. FLASH can be orally administered to modulate GI hormones and is safely excreted with no adverse effects in porcine models. We anticipate that this device could be used to treat metabolic, GI, and neuropsychiatric disorders noninvasively with minimal off-target effects.


Assuntos
Fome , Robótica , Animais , Suínos , Hormônios
3.
Sci Adv ; 8(1): eabk1792, 2022 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-34985942

RESUMO

Oral drug administration remains the preferred route for patients and health care providers. Delivery of macromolecules through this route remains challenging because of limitations imposed by the transport across the gastrointestinal epithelium and the dynamic and degradative environment. Here, we present the development of a delivery system that combines physical (microneedle) and nonphysical (enhancer) modes of drug delivery enhancement for a macromolecule in a large animal model. Inspired by the thorny-headed intestinal worm, we report a dynamic omnidirectional mucoadhesive microneedle system capable of prolonged gastric mucosa fixation. Moreover, we incorporate sodium N-[8-(2-hydroxybenzoyl) amino] caprylate along with semaglutide and demonstrate enhanced absorption in swine resistant to physical displacement in the gastric cavity. Meanwhile, we developed a targeted capsule system capable of deploying intact microneedle-containing systems. These systems stand to enable the delivery of a range of drugs through the generation and maintenance of a privileged region in the gastrointestinal tract.

4.
ACS Pharmacol Transl Sci ; 3(6): 1076-1082, 2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33330837

RESUMO

N95 filtering facepiece respirators (FFR) and surgical masks are essential in reducing airborne disease transmission, particularly during the COVID-19 pandemic. However, currently available FFR's and masks have major limitations, including masking facial features, waste, and integrity after decontamination. In a multi-institutional trial, we evaluated a transparent, elastomeric, adaptable, long-lasting (TEAL) respirator to evaluate success of qualitative fit test with user experience and biometric evaluation of temperature, respiratory rate, and fit of respirator using a novel sensor. There was a 100% successful fit test among participants, with feedback demonstrating excellent or good fit (90% of participants), breathability (77.5%), and filter exchange (95%). Biometric testing demonstrated significant differences between exhalation and inhalation pressures among a poorly fitting respirator, well-fitting respirator, and the occlusion of one filter of the respirator. We have designed and evaluated a transparent elastomeric respirator and a novel biometric feedback system that could be implemented in the hospital setting.

5.
BMJ Open ; 10(7): e039120, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32641368

RESUMO

OBJECTIVE: To develop and test a new reusable, sterilisable N95 filtering facepiece respirator (FFR)-comparable face mask, known as the Injection Molded Autoclavable, Scalable, Conformable (iMASC) system, given the dire need for personal protective equipment within healthcare settings during the COVID-19 pandemic. DESIGN: Single-arm feasibility study. SETTING: Emergency department and outpatient oncology clinic. PARTICIPANTS: Healthcare workers who have previously undergone N95 fit testing. INTERVENTIONS: Fit testing of new iMASC system. PRIMARY AND SECONDARY OUTCOME MEASURES: Primary outcome is success of fit testing using an Occupational Safety and Health Administration (OSHA)-approved testing method, and secondary outcomes are user experience with fit, breathability and filter replacement. RESULTS: Twenty-four subjects were recruited to undergo fit testing, and the average age of subjects was 41 years (range of 21-65 years) with an average body mass index of 26.5 kg/m2. The breakdown of participants by profession was 46% nurses (n=11), 21% attending physicians (n=5), 21% resident physicians (n=5) and 12% technicians (n=3). Of these participants, four did not perform the fit testing due to the inability to detect saccharin solution on premask placement sensitivity test, lack of time and inability to place mask over hair. All participants (n=20) who performed the fit test were successfully fitted for the iMASC system using an OSHA-approved testing method. User experience with the iMASC system, as evaluated using a Likert scale with a score of 1 indicating excellent and a score of 5 indicating very poor, demonstrated an average fit score of 1.75, breathability of 1.6, and ease of replacing the filter on the mask was scored on average as 2.05. CONCLUSIONS: The iMASC system was shown to successfully fit multiple different face sizes and shapes using an OSHA-approved testing method. These data support further certification testing needed for use in the healthcare setting.


Assuntos
Infecções por Coronavirus/prevenção & controle , Desenho de Equipamento , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Dispositivos de Proteção Respiratória , Elastômeros de Silicone , Adulto , Idoso , Pessoal Técnico de Saúde , Betacoronavirus , COVID-19 , Infecções por Coronavirus/transmissão , Reutilização de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Enfermeiras e Enfermeiros , Médicos , Pneumonia Viral/transmissão , Estudos Prospectivos , SARS-CoV-2 , Esterilização , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...