Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Journal of Chinese Physician ; (12): 35-38,43, 2022.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-932021

RESUMO

Objective:To investigate the correlation between serum anti phospholipase A2 receptor (PLA 2R) antibody level and the condition and prognosis of patients with primary membranous nephropathy (PMN).Methods:61 patients who were diagnosed as PMN in the laboratory department of Jiangsu Province Hospital of Chinese Medicine from January 2017 to August 2019 were selected and divided into PLA 2R positive group (41 cases) and PLA 2R negative group (20 cases) according to the level of PLA 2R antibody. The gender, age and other general data of the two groups were collected, and the clinical pathological characteristics and prognosis of the two groups were analyzed. Spearman correlation was used to analyze the correlation between the level of PLA 2R antibody and the disease condition and treatment prognosis.Results:The levels of estimate glomerular filtration rate (eGFR), total protein (TP) and albumin (ALB) in PLA 2R positive group were lower than those in PLA 2R negative group, while the levels of 24-h urinary protein and IgG4 were higher in PLA 2R positive group than that in PLA 2R negative group ( P<0.05); Multivariate logistic regression analysis showed that 24-hour urinary protein was an independent risk factor for PLA 2R antibody level ( OR=2.242, P<0.05), while TP and ALB levels were protective factors ( OR=0.840, 0.674, P<0.05); The patients in both groups were followed up for one year by rechecking serological indexes. The complete remission rate and total remission rate of PLA 2R positive group were lower than those of PLA 2R negative group ( P<0.05); Spearman correlation analysis showed that the level of PLA 2R antibody was negatively correlated with the levels of TP, ALB, and prognosis of patients ( r=-0.642, -0.547, -0.357, P<0.05), and positively correlated with the level of 24-hour urinary protein ( r=0.347, P<0.05). PLA 2R in renal tissue of 61 patients was found to be positive in 63.93% (39/61). Conclusions:The level of PLA 2R antibody is closely related to serum albumin, TP, 24 h urinary protein and prognosis of patients with PMN.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-476099

RESUMO

Objective The present study is to investigate the influence of vaginal discharge on dry chemistry determination of leukocyte esterase in female urine.Methods Collected 20 and 30 normal vaginal discharge samples.Which humoral routine test degree were Ⅰ and Ⅱ correspondingly,and then analyze leukocyte esterase and squamous epithelial cells in these normal vaginal discharge samples.Collected normal vaginal discharge samples again and isolate the vaginal squamous epithelial cells from those normal vaginal discharge samples.Made two concentration of squamous epithelial cell suspension liquid (20/μl and 60/μl)and added these liquid.To normal female urine and analyze the drying chemical leukocyte esterase in those urine. Cleaned the vulva of those patients with normal leukocyte counts in urine sediment determination,whose dry chemical deter-mination of leukocyte esterase was strong positive,perform the routine urine test with her middle urine.Results The results of the determination of leukocyte esterase in normal vaginal discharge samples were 66.7% positive.And there were ~squamous epithelial cells in all samples (microscopy).No significant difference was observed in the examination of dry chem-istry leukocyte esterase among the normal female urine group,low (20/μl)and high (60/μl)concentrations of squamous epi-thelial cell urine group (P >0.05).The counts of squamous epithelial cells and the rate of positive and intensity of dry chem-ical leukocyte esterase in the middle of second urine were significantly lower than before,and the differences are statistically significant (P <0.05).But there was no significant difference for leukocytes counts.Conclusion Urine squamous epithelial cells had no influence on the detection of leukocyte esterase by dry chemistry.However,the leukocyte esterase in the vaginal discharge greatly influenced the examination of the leukocyte esterase in urine.

3.
Clin Lab ; 60(10): 1627-34, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25651707

RESUMO

BACKGROUND: The aim of the study was to perform an internal comparison of blood cell analyses: white blood cell (WBC) and platelet (PLT) counts in a clinical laboratory. METHODS: Instrument comparison: Based on EP9-A2 of the Clinical Laboratory and Standard Institute (CLSI) and the statistics program of External Quality Assessment (EQA), we set 1/2CLIA'88 as our quality standard and used a Beckman coulter LH750 as the reference. We then compared this to another 4 blood analyzers: the Beckman Coulter Gen-S, ABX pentra 60, and the Sysmex XT2000i and XS-800i, including the Beckman Coulter Gen-S in manual mode. Personnel comparison: WBC and PLT counts were performed on five samples by 13 technicians at random. Two statistics programs were used to calculate the bias of each technician. The results were compared with the 1/2 CLIA'88 standard to evaluate staff performance. RESULTS: All instrument comparisons met our quality standards of WBC < 7.5% and PLT < 12.5%. However, five technicians did not achieve satisfactory results of the WBC count in the first assessment. The coefficient of variation (CV) among qualified staff assessing five samples ranged from 8.51% to 12.2%, but all exceeded the 1/2 CLIA'88 quality standard; however, the CVs of 2 samples among qualified staff were approximately 20%, but after strict training this variability reduced significantly to approximately 5%. CONCLUSIONS: Instrument comparisons demonstrated achievement of quality goals under rigorous calibration and quality control, but CVs were comparatively large. This improved following strict training, so a laboratory should emphasize the training and assessment of staff and evaluation of the actual situation when selecting a qualification program.


Assuntos
Técnicas de Laboratório Clínico/normas , Hematologia/normas , Laboratórios/normas , Contagem de Leucócitos/normas , Contagem de Plaquetas/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Fluxo de Trabalho , Técnicas de Laboratório Clínico/instrumentação , Desenho de Equipamento , Hematologia/instrumentação , Humanos , Contagem de Leucócitos/instrumentação , Variações Dependentes do Observador , Contagem de Plaquetas/instrumentação , Controle de Qualidade , Reprodutibilidade dos Testes
4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-443990

RESUMO

Objective To analyze the relevance between the point-of-care testing (POCT) and routine test in BNP testing .Meth-ods The whole blood samples or plasma samples from 40 inpatients were detected brain natriuretic peptide (BNP) by the Alere Triage? MeterPro fluorescence immunoassay analyzer (POCT ) or the Beckman Coulter Access ?2 chemiluminescence analyzer (routine test) ,respectively .The acquired data were subjected to comparative analysis according to the CLCS EP 9-A2 .Results The linear regression of the BNP content in the blood samples detected by POCT and the routine test was good ,the correlation coeffi-cient(r) was 0 .999 7 .Conclusion POCT and the routine test have good correlation in BNP testing .POCT for BNP testing has higher reliability and is applicable for clinical detection .

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...