Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-774196

RESUMO

This paper explored the feasibility of using ultrasonic Nakagami statistic parameter imaging to evaluate the thermal lesion induced by microwave ablation (MWA) in porcine models. In this paper, thermal lesions were induced in livers and kidneys in 5 swines using a clinical MWA system. During this treatment progress, ultrasonic radiofrequency (RF) data were collected. The dynamic changes of Nakagami parameter in the thermal lesion were calculated, and the ultrasonic B-mode images and Nakagami images were reconstructed simultaneously. The contrast-to-noise ratio (CNR) between the thermal lesion and the surrounding normal tissue was calculated over the MWA procedure. After MWA, a bright hyperechoic region appeared in the ultrasonic Nakagami image as an indicator of the thermal lesion and this bright spot enlarged with lesion development during MWA exposure. The mean value of Nakagami parameter in the liver and kidney increased from 0.78 and 0.79 before treatment to 0.91 and 0.92 after treatment, respectively. During MWA exposure, the mean values of CNR calculated from the Nakagami parameter increased from 0.49 to 1.13 in the porcine liver and increased from 0.51 to 0.85 in the kidney, which were both higher than those calculated from the B-mode images. This study on porcine models suggested that the ultrasonic Nakagami imaging may provide an alternative modality for monitoring MWA treatment.


Assuntos
Animais , Rim , Diagnóstico por Imagem , Fígado , Diagnóstico por Imagem , Micro-Ondas , Ondas de Rádio , Ablação por Radiofrequência , Suínos , Ultrassonografia
2.
Biomed Pharmacother ; 64(9): 615-23, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20888179

RESUMO

We prepared the core-shell structure adriamycin lipiodol microemulsions (ADM-CSLMs) and evaluated their in vivo antitumor effects in combination with Diethyldithiocarbamate (DDC). Two types of ADM-CSLMs, adriamycin liposome-lipiodol microemulsion(ADM-LLM) and adriamycin microsphere lipiodol microemulsion (ADM-MLM), were prepared through the emulsification method. The drug loading and encapsulation efficiency of ADM-CSLMs were measured by the high-performance liquid chromatograph (HPLC). The size and shape of the ADM-CSLMs were determined by an atom force microscopy (AFM), a transmission electron microscopy (TEM), and a particle size analyzer, respectively. The synergistic effects of DDC and ADM-CSLMs for cancer treatment of carcinoma drug-resistance cell was evaluated by the MTT method, the activation of superoxide dismutase (SOD) was detected by chemiluminescence, and the ADM accumulation in cells was measured by flow cytometry. Walker-256 carcinoma was transplanted to the livers of the male SD rats, ADM-CSLMs were administrated to the livers of the rats by intervention hepatic artery embolization through microsurgery. The tumor growth and animal survival were evaluated. The results show that the average diameter of ADM-LLM and ADM-MLM were 4.23 ± 1.2 µm and 4.67 ± 1.4 µm, respectively, and their ADM encapsulation efficiency were 83.7% and 87.2% with respect to loading efficiency of 82 µg/ml and 91 µg/ml. The tumor growth and animal survival in two of the ADM-CSLMs combined with DDC groups were significantly higher than that of ADM only treatment, ADM liposome combined with DDC (P < 0.01), as well as the ADM microsphere combined with DDC (P < 0.01). Therefore, ADM-CSLMs are useful carriers for the treatment of carcinoma and their anti-tumor effect can be enhanced by DDC in a suitable concentration.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/farmacologia , Ditiocarb/farmacologia , Doxorrubicina/farmacologia , Emulsões/síntese química , Óleo Etiodado/química , Animais , Linhagem Celular Tumoral , Ditiocarb/administração & dosagem , Doxorrubicina/administração & dosagem , Doxorrubicina/química , Doxorrubicina/farmacocinética , Sinergismo Farmacológico , Humanos , Lipossomos/síntese química , Lipossomos/ultraestrutura , Masculino , Tamanho da Partícula , Ratos , Ratos Sprague-Dawley , Ensaios Antitumorais Modelo de Xenoenxerto/métodos
3.
Journal of Biomedical Engineering ; (6): 1093-1097, 2008.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-318207

RESUMO

The genetic optimal algorithm and sound field calculation approach for the spherical-section phased array are presented in this paper. The in-house manufactured 256-element phased array focused ultrasound surgery system is briefly described. The on-axis single focus and off-axis single focus are simulated along with the axis-symmetric six-focus patter and the axis-asymmetric four-focus pattern using a 256-element phased array and the genetic optimal algorithm and sound field calculation approach. The experimental results of the described 256-element phased array focused ultrasound surgery system acting on organic glass and phantom are also analyzed. The results of the simulations and experiments confirm the applicability of the genetic algorithm and field calculation approaches in accurately steering three dimensional foci and focus.


Assuntos
Humanos , Algoritmos , Simulação por Computador , Desenho de Equipamento , Procedimentos Cirúrgicos Minimamente Invasivos , Métodos , Modelos Biológicos , Cirurgia Assistida por Computador , Métodos , Transdutores , Terapia por Ultrassom , Métodos
4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-340930

RESUMO

In this symposium, we reviewed the principle and development of time-resolved fluorescence anisotropy measurement. Its method of measurement, characteristics and applications in the research of biomacromolecule, configuration and molecular structure have been discussed. Its potential applications are also illustrated.


Assuntos
Polarização de Fluorescência , Métodos , Substâncias Macromoleculares , Matemática , Modelos Moleculares , Fatores de Tempo
5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-554396

RESUMO

Objective To show the feasibility and value in the diagnosis of airway obstruction and pulmonary embolism with MR oxygen-enhanced ventilation combined with pulmonary perfusion imaging. Methods Eight canines were implemented for peripheral pulmonary embolism by intravenous injection of gelfoam granules at pulmonary segmental arterial level, and five of them were formed airway obstruction models by inserting self-made balloon catheter at second-bronchia. The oxygen-enhanced MR ventilation imaging was introduced by subtracting the images of pre- and post- inhaled pure oxygen. The MR pulmonary perfusion imaging was achieved by the first-pass contrast agent method. Moreover, the manifestation of MR ventilation and perfusion imaging was observed and contradistinguished with that of general pathologic anatomy, ventilation-perfusion scintigraphy, and pulmonary angiography. Results The manifestations of airway obstruction regions in MR ventilation and perfusion imaging were matched, but those of pulmonary embolism regions were dismatched. The defect range of airway obstruction in MR ventilation image was smaller than that in ventilation scintigraphy. The abnormal perfusion regions of pulmonary embolism were divided into defect regions and reduce regions based on the time courses of signal intensity changes. The sensitivity and specificity of diagnosis on pulmonary embolism by MR ventilation combined with perfusion technique were 75.0% and 98.1%. The diagnostic results were in good coherence with ventilation-perfusion scintigraphy and pulmonary angiography(K=0.743, 0.899). Conclusion The MR oxygen-enhanced ventilation combined with pulmonary perfusion imaging can be used to diagnose the airway and vascular abnormity in lung. This technique resembles the ventilation-perfusion scintigraphy. It can provide quantitative functional information and better spatial and temporal resolution, and possesses the value of clinical application.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...