Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 156: 106581, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38776740

RESUMO

Patient-specific fabrication of scaffold/implant requires an engineering approach to manufacture the ideal scaffold. Herein, we design and 3D print scaffolds comprised of polyether-ether-ketone (PEEK) and sodium-carboxymethyl cellulose (Na-CMC). The fabricated scaffold was dip coated with Zn and Mn doped bioactive glass nanoparticles (Zn-Mn MBGNs). The synthesized ink exhibit suitable shear-thinning behavior for direct ink write (DIW) 3D printing. The scaffolds were crafted with precision, featuring 85% porosity, 0.3 mm layer height, and 1.5 mm/s printing speed at room temperature. Scanning electron microscopy images reveal a well-defined scaffold with an average pore size of 600 ± 30 µm. The energy dispersive X-ray spectroscopy analysis confirmed a well dispersed/uniform coating of Zn-Mn MBGNs on the PEEK/Na-CMC scaffold. Fourier transform infrared spectroscopy approved the presence of PEEK, CMC, and Zn-Mn MBGNs. The tensile test revealed a Young's modulus of 2.05 GPa. Antibacterial assays demonstrate inhibition zone against Staphylococcus aureus and Escherichia Coli strains. Chick Chorioallantoic Membrane assays also present significant angiogenesis potential, owing to the antigenic nature of Zn-Mn MBGNs. WST-8 cell viability assays depicted cell proliferation, with a 103% viability after 7 days of culture. This study suggests that the PEEK/Na-CMC scaffolds coated with Zn-Mn MBGNs are an excellent candidate for osteoporotic fracture treatment. Thus, the fabricated scaffold can offer multifaceted properties for enhanced patient outcomes in the bone tissue regeneration.


Assuntos
Benzofenonas , Carboximetilcelulose Sódica , Vidro , Cetonas , Manganês , Nanopartículas , Polietilenoglicóis , Polímeros , Impressão Tridimensional , Staphylococcus aureus , Alicerces Teciduais , Zinco , Porosidade , Benzofenonas/química , Vidro/química , Cetonas/química , Cetonas/farmacologia , Alicerces Teciduais/química , Staphylococcus aureus/efeitos dos fármacos , Carboximetilcelulose Sódica/química , Nanopartículas/química , Zinco/química , Zinco/farmacologia , Polímeros/química , Manganês/química , Polietilenoglicóis/química , Antibacterianos/química , Antibacterianos/farmacologia , Animais , Escherichia coli/efeitos dos fármacos , Teste de Materiais , Humanos
2.
J Mech Behav Biomed Mater ; 148: 106188, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37856992

RESUMO

Electrophoretic deposition (EPD) of polyether ether ketone (PEEK) coatings on metallic implants has recently attracted a great deal of interest; however, further investigation into their corrosion, surface, and tribological properties is required for their clinical application. Using Potentiodynamic polarization and Mott-Schottky analysis of PEEK coatings, we analyzed the electrochemical corrosion behavior of electrophoretically deposited PEEK coatings on 316L stainless steel (SS) substrates. In addition, the tribological behavior of the coatings was determined through pin-on-disc and scratch testing. Initially, the EPD parameters were optimized using a Taguchi Design of Experiment (DoE) approach. The coatings exhibited irregular shaped grains along with ∼66 µm of thickness. Fourier transform infrared spectroscopy confirmed the presence of functional groups ascribed with PEEK. The coatings were moderately hydrophobic and had an average roughness of ∼2 µm. The corrosion studies demonstrated promising features of current density and corrosion potential, indicating that corrosion resistance significantly improves with PEEK coating. Electrochemical impedance spectroscopy also confirmed the corrosion resistance of PEEK coating. The coatings exhibited a slightly lower wear resistance than SS samples, but still possessed adequate wear and scratch resistance for biomedical applications. The current study confirmed that the PEEK coatings on metallic implants is effective for orthopedic applications where corrosion and tribology are major concerns.


Assuntos
Materiais Revestidos Biocompatíveis , Aço Inoxidável , Aço Inoxidável/química , Materiais Revestidos Biocompatíveis/química , Corrosão , Polietilenoglicóis/química , Cetonas/química , Éteres
3.
Sci Rep ; 13(1): 17842, 2023 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-37857655

RESUMO

The most important challenge faced in designing orthopedic devices is to control the leaching of ions from the substrate material, and to prevent biofilm formation. Accordingly, the surgical grade stainless steel (316L SS) was electrophoretically deposited with functional composition of biopolymers and bioceramics. The composite coating consisted of: Bioglass (BG), hydroxyapatite (HA), and lawsone, that were loaded into a polymeric matrix of Xanthan Dialdehyde/Chondroitin Sulfate (XDA/CS). The parameters and final composition for electrophoretic deposition were optimized through trial-and-error approach. The composite coating exhibited significant adhesion strength of "4B" (ASTM D3359) with the substrate, suitable wettability of contact angle 48°, and an optimum average surface roughness of 0.32 µm. Thus, promoting proliferation and attachment of bone-forming cells, transcription factors, and proteins. Fourier transformed infrared spectroscopic analysis revealed a strong polymeric network formation between XDA and CS. scanning electron microscopy and energy dispersive X-ray spectroscopy analysis displayed a homogenous surface with invariable dispersion of HA and BG particles. The adhesion, hydrant behavior, and topography of said coatings was optimal to design orthopedic implant devices. The said coatings exhibited a clear inhibition zone of 21.65 mm and 21.04 mm with no bacterial growth against Staphylococcus aureus (S. Aureus) and Escherichia coli (E. Coli) respectively, confirming the antibacterial potential. Furthermore, the crystals related to calcium (Ca) and HA were seen after 28 days of submersion in simulated body fluid. The corrosion current density, of the above-mentioned coating was minimal as compared to the bare 316L SS substrate. The results infer that XDA/CS/BG/HA/lawsone based composite coating can be a candidate to design coatings for orthopedic implant devices.


Assuntos
Durapatita , Staphylococcus aureus , Durapatita/química , Escherichia coli , Polímeros/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química
4.
ACS Omega ; 8(20): 18074-18089, 2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37251160

RESUMO

There is an urgent need to develop biodegradable implants that can degrade once they have fulfilled their function. Commercially pure magnesium (Mg) and its alloys have the potential to surpass traditional orthopedic implants due to their good biocompatibility and mechanical properties, and most critically, biodegradability. The present work focuses on the synthesis and characterization (microstructural, antibacterial, surface, and biological properties) of poly(lactic-co-glycolic) acid (PLGA)/henna (Lawsonia inermis)/Cu-doped mesoporous bioactive glass nanoparticles (Cu-MBGNs) composite coatings deposited via electrophoretic deposition (EPD) on Mg substrates. PLGA/henna/Cu-MBGNs composite coatings were robustly deposited on Mg substrates using EPD, and their adhesive strength, bioactivity, antibacterial activity, corrosion resistance, and biodegradability were thoroughly investigated. Scanning electron microscopy and Fourier transform infrared spectroscopy studies confirmed the uniformity of the coatings' morphology and the presence of functional groups that were attributable to PLGA, henna, and Cu-MBGNs, respectively. The composites exhibited good hydrophilicity with an average roughness of 2.6 µm, indicating desirable properties for bone forming cell attachment, proliferation, and growth. Crosshatch and bend tests confirmed that the adhesion of the coatings to Mg substrates and their deformability were adequate. Electrochemical Tafel polarization tests revealed that the composite coating adjusted the degradation rate of Mg substrate in a human physiological environment. Incorporating henna into PLGA/Cu-MBGNs composite coatings resulted in antibacterial activity against Escherichia coli and Staphylococcus aureus. The coatings stimulated the proliferation and growth of osteosarcoma MG-63 cells during the initial incubation period of 48 h (determined by the WST-8 assay).

5.
Materials (Basel) ; 14(5)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802436

RESUMO

By anodization and thermal oxidation at 600 °C, an oxide layer on Ti with excellent corrosion resistance in strong acid solutions was prepared. The structural properties of TiO2 films before and after thermal oxidation were investigated with methods of Scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). The electrochemical characterization was recorded via electrochemical impedance spectroscopy, potentiodynamic polarization and Mott-Schottky methods. XRD results show that a duplex rutile/anatase structure formed after oxidation, and the amount of anatase phase increased as the treatment time was prolonged from 3 to 9 h. XPS analysis indicates that as the thermal oxidation time increased, more Ti vacancies were present in the titanium oxide films, with decreased donor concentration. Longer thermal oxidation promoted the formation of hydroxides of titanium on the surface, which is helpful to improve the passive ability of the film. The anodized and thermally oxidized Ti samples showed relatively high corrosion resistance in 4 M HCl and 4 M H2SO4 solutions at 100 ± 5 °C. The passive current density values of the thermally oxidized samples were five orders of magnitude under the testing condition compared with that of the anodized sample. With the oxidation time prolonged, the passive current density decreased further to some extent.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...