Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 20951, 2023 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-38016964

RESUMO

3D imaging technology is becoming more prominent every day. However, more validation is needed to understand the actual benefit of 3D versus conventional 2D vision. This work quantitatively investigates whether experts benefit from 3D vision during minimally invasive fetoscopic spina bifida (fSB) repair. A superiority study was designed involving one expert team ([Formula: see text] procedures prior) who performed six 2D and six 3D fSB repair simulations in a high-fidelity animal training model, using 3-port access. The 6D motion of the instruments was recorded. Among the motion metrics are total path length, smoothness, maximum speed, the modified Spectral Arc Length (SPARC), and Log Dimensionless Jerk (LDLJ). The primary clinical outcome is operation time (power 90%, 5% significance) using Sealed Envelope Ltd. 2012. Secondary clinical outcomes are water tightness of the repair, CO[Formula: see text] insufflation volume, and OSATS score. Findings show that total path length and LDLJ are considerably different. Operation time during 3D vision was found to be significantly shorter compared to 2D vision ([Formula: see text] vs. [Formula: see text] min; p [Formula: see text] 0.026). These results suggest enhanced performance with 3D vision during interrupted suturing in fetoscopic SBA repair. To confirm these results, a larger-scale follow-up study involving multiple experts and novice surgeons is recommended.


Assuntos
Fetoscopia , Disrafismo Espinal , Gravidez , Feminino , Humanos , Fetoscopia/métodos , Seguimentos , Procedimentos Neurocirúrgicos , Imageamento Tridimensional , Disrafismo Espinal/cirurgia
2.
Environ Sci Pollut Res Int ; 30(51): 110658-110673, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37792184

RESUMO

Heavy metals (HMs) in water are highly poisonous and carcinogenic agents for human health. To alleviate the toxic impacts of HMs, green remediation technologies are the need of the hour. In this regard, different nanosorbents (CMCG@ORP, ORAC, NiO/NPs, and NiO@ORAC/NCs) were synthesized in the present study, and the percentage removal of heavy metals [chromium(VI) and cadmium(II) ions] was evaluated. The nanosorbents were characterized by using FTIR, SEM, UV-Vis spectroscopy, and XRD. UV-Vis spectroscopy confirmed the synthesis of nanosorbents such as NiO/NPs and NiO@ORAC/NCs at 330.5 nm and 352.55 nm, respectively. The characterization studies show that the surface of synthesized nano-sorbents was highly coarse, uneven, and abrasive. XRD pattern deduced that the sample was of single phase, and no other impurity was detected except the face-centered cubic-phase peak of NiO. The maximum adsorption of Cd (91%) and Cr (92%) was found at initial concentrations of 100 and 60 ppm respectively at contact time = 180 min, temperature 25 °C, and with an adsorbent dose of 0.5 g. Isothermal, kinetic, and thermodynamic studies were also performed to evaluate the adsorption mechanisms and feasibility of the process. Adsorption mostly followed Freundlich isotherm which indicates the multilayer adsorption phenomenon and the negative value of Gibb's free energy showed the spontaneous nature and feasibility of the adsorption reaction. Surface complexation, ion exchange, surface precipitation, and the phenomenon of physical adsorption occurred on the sorbent surface which led to the attachment of Cd and Cr to the tested nanosorbents. In conclusion, NiO@ORAC/NCs were the most effective in the alleviation of Cd(II) and Cr(VI) ions in contaminated water.


Assuntos
Metais Pesados , Poluentes Químicos da Água , Humanos , Cádmio , Adsorção , Poluentes Químicos da Água/análise , Cromo/química , Água/química , Termodinâmica , Cinética , Concentração de Íons de Hidrogênio
3.
Int J Comput Assist Radiol Surg ; 18(9): 1603-1611, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37165257

RESUMO

PURPOSE: Fetoscopic laser coagulation for twin-to-twin transfusion syndrome is challenging for anterior placenta due to the rigidity of current tools. The capacity to keep entry port forces minimal is critical for this procedure, as is optimal coagulation distance and orientation. This work introduces technological tools to this end. METHODS: A novel fetoscope is presented with a rigid shaft and a flexible steerable segment at the distal end. The steerable segment can bend up to 90[Formula: see text] even when loaded with a laser fiber. An artificial pneumatic muscle makes such acute bending possible while allowing for a low-weight and disposable device. RESULTS: The flexible fetoscope was validated in a custom-made phantom model to measure visual range and coagulation efficacy. The flexible fetoscope shows promising results when compared to a clinical rigid curved fetoscope to reach anterior targets. The new fetoscope was then evaluated in vivo (pregnant ewe) where it successfully coagulated placental vasculature. CONCLUSION: The flexible fetoscope improved the ability to achieve optimal coagulation angle and distance on anteriorly located targets. The fetoscope also showed the potential to lead fetoscopic laser coagulation and other fetal surgical procedures toward safer and more effective interventions.


Assuntos
Transfusão Feto-Fetal , Placenta , Gravidez , Feminino , Humanos , Placenta/irrigação sanguínea , Fetoscópios , Fotocoagulação a Laser/métodos , Fetoscopia/métodos , Transfusão Feto-Fetal/cirurgia
4.
Int J Comput Assist Radiol Surg ; 15(9): 1561-1571, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32350788

RESUMO

PURPOSE: Twin-to-twin transfusion syndrome (TTTS) is a placental defect occurring in monochorionic twin pregnancies. It is associated with high risks of fetal loss and perinatal death. Fetoscopic elective laser ablation (ELA) of placental anastomoses has been established as the most effective therapy for TTTS. Current tools and techniques face limitations in case of more complex ELA cases. Visualization of the entire placental surface and vascular equator; maintaining an adequate distance and a close to perpendicular angle between laser fiber and placental surface are central for the effectiveness of laser ablation and procedural success. Robot-assisted technology could address these challenges, offer enhanced dexterity and ultimately improve the safety and effectiveness of the therapeutic procedures. METHODS: This work proposes a 'minimal' robotic TTTS approach whereby rather than deploying a massive and expensive robotic system, a compact instrument is 'robotised' and endowed with 'robotic' skills so that operators can quickly and efficiently use it. The work reports on automatic placental pose estimation in fetoscopic images. This estimator forms a key building block of a proposed shared-control approach for semi-autonomous fetoscopy. A convolutional neural network (CNN) is trained to predict the relative orientation of the placental surface from a single monocular fetoscope camera image. To overcome the absence of real-life ground-truth placenta pose data, similar to other works in literature (Handa et al. in: Proceedings of the IEEE conference on computer vision and pattern recognition, 2016; Gaidon et al. in: Proceedings of the IEEE conference on computer vision and pattern recognition, 2016; Vercauteren et al. in: Proceedings of the IEEE, 2019) the network is trained with data generated in a simulated environment and an in-silico phantom model. A limited set of coarsely manually labeled samples from real interventions are added to the training dataset to improve domain adaptation. RESULTS: The trained network shows promising results on unseen samples from synthetic, phantom and in vivo patient data. The performance of the network for collaborative control purposes was evaluated in a virtual reality simulator in which the virtual flexible distal tip was autonomously controlled by the neural network. CONCLUSION: Improved alignment was established compared to manual operation for this setting, demonstrating the feasibility to incorporate a CNN-based estimator in a real-time shared control scheme for fetoscopic applications.


Assuntos
Aprendizado Profundo , Transfusão Feto-Fetal/cirurgia , Fetoscopia/instrumentação , Fotocoagulação a Laser/instrumentação , Placenta/cirurgia , Robótica , Cirurgia Assistida por Computador/instrumentação , Simulação por Computador , Feminino , Humanos , Terapia a Laser , Movimento (Física) , Redes Neurais de Computação , Gravidez , Reprodutibilidade dos Testes
5.
IEEE Robot Autom Lett ; 3(4): 4359-4366, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34109273

RESUMO

The twin-to-twin transfusion syndrome is a severe fetal anomaly appearing in up to 15% of identical twin pregnancies. This anomaly occurs when twins share blood vessels from a common placenta. The complication leads to an unbalanced blood transfusion between both fetuses. A current surgical treatment consists in coagulating the shared vessels using a fetoscope with an embedded laser. Such treatment is very delicate and constraining due to limited vision and size of the insertion area. The rigidity and lack of controllability of the current used instruments add an additional difficulty and limit the choice in insertion site. This letter proposes an improved flexible fetoscope, offering an enhanced laser controllability and higher versatility regarding the location of the insertion site. A better approach angle can therefore be realized. Also, tissue damage may be further reduced. This single-handed controllable active fetoscope is obtained after adaptation of a LithoVue (Boston Scientific, Natick, MA, USA), a commercially available passive flexible ureteroscope. The LithoVue is fitted with a unique lightweight add-on actuation module foreseen of an artificial muscle and a dedicated control system. Experiments in a mixed reality trainer suggested that the proposed fetoscope is compact, ergonomic, and intuitive in use, allowing an adequate control of the flexible end.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...