Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Asian J Neurosurg ; 19(2): 168-173, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38974449

RESUMO

Objective With the expansion of indications of flow diverter (FD) for cerebral aneurysms, FD placement for posterior communicating artery (Pcom) aneurysms has been approved. However, it is controversial whether Pcom aneurysms should be treated with FD or not. In this study, we report the outcome of FD treatment for Pcom aneurysms in Japan. Materials and Methods We retrospectively analyzed 36 patients with 38 aneurysms treated with FD placement for Pcom aneurysms between 2015 and 2021 in our hospital. We divided our cases into complete occlusion (CO) and non-CO groups. And we extracted contributing factors to CO using multivariate analysis. We also compared the complications rate among the three types of FDs. Results CO was obtained in 29 cases (79.3%), and complications were observed in 3 cases (7.9%). Multivariate analysis revealed that the type of Pcom branch from the aneurysmal dome was a significant factor contributing to CO (odds ratio: 0.0052, 95% confidence interval 0.000048-0.584, p = 0.029). In terms of complications, complication rate was significantly higher in the Flow-Redirection Endoluminal Device (FRED) group ( p = 0.0491). Conclusion The outcome for Pcom aneurysms treated by FD was acceptable. When treating, we must pay attention to where Pcom originates. Achieving CO with FD is difficult for aneurysms where the Pcom branches from the dome. Furthermore, when treating Pcom aneurysms with FRED, it is necessary to be careful about thromboembolic complications.

2.
J Neuroendovasc Ther ; 18(3): 65-74, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559453

RESUMO

Treatment for wide-neck bifurcation cerebral aneurysms (WNBAs) is widely performed by endovascular treatment as well as open surgical clipping. However, due to factors such as the shape and size of the aneurysms, as well as the anatomical features of surrounding branch vessels, there are some cases in which simple coiling or conventional adjunctive techniques, such as balloon-assisted or neck bridge stent-assisted coiling, are not sufficient to achieve a satisfactory cure. Against this backdrop, the device known as the Woven EndoBridge (WEB) (MicroVention, Aliso Viejo, CA, USA) was developed and can be deployed directly into the aneurysm for treatment. Over a decade has passed since its development, and it is now used in many countries worldwide. This review provides insights into the evolution of the WEB device from its development to the date of this writing, highlighting the unique features of the device and its treatment indications. Additionally, it discusses the posttreatment course, perspectives on recurrence and retreatment, imaging assessments, and potential off-label use based on numerous studies primarily conducted in Europe and the USA.

3.
Neuroradiol J ; 37(1): 54-59, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37902468

RESUMO

PURPOSE: Recently, a novel device, the Woven Endo Bridge (WEB), was developed for wide-neck bifurcation intracranial aneurysms (WNBAs). The aim of this study is to investigate factors that contribute to adequate occlusion (AO) after the operation using detailed radiological images. METHODS: The subjects were 29 patients with 29 aneurysms who received WEB implantation for WNBAs between December 2020 and April 2022. We assessed the contributing factors to AO by retrospectively comparing the AO group and non-AO group. RESULTS: The mean age was 64.6 ± 13.1 years, and 18 were female (62.1%). The mean aneurysm dome width, aneurysm height, and aneurysm neck diameter were 4.8 ± 0.6 mm, 5.1 ± 0.6 mm, and 3.7 ± 0.6 mm, respectively. After about 6 months, 22 of 29 patients (75.9%) had AO. Complications were observed in 2 patients (6.9%), renal artery injury in one, and minor cerebral infarction in another, but the modified Rankin scale scores of both patients remained unchanged. Multivariate analysis extracted only WEB shape modification (WSM) as a contributing factor to AO (odds ratio: 0.912, p = 0.0287). CONCLUSION: WEB implantation for WNBAs was a treatment modality with acceptable efficacy and safety. WSM was the only significant factor contributing to non-AO after the treatment. We should clarify the mechanisms or causes of WSM to achieve AO after WEB implantation in future.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Embolização Terapêutica/métodos
4.
Surg Neurol Int ; 14: 92, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37025526

RESUMO

Background: The pipeline embolization device (PED) is the most common flow diverter device in the world. To date, there have been no reports of treatment outcomes specific to intradural internal carotid artery (ICA) aneurysms. The safety and efficacy of the PED treatments for intradural ICA aneurysms are reported. Methods: 131 patients with 133 aneurysms underwent PED treatments for intradural ICA aneurysms. The mean aneurysm dome size and neck length were 12.7 ± 4.3 mm and 6.1 ± 2.2 mm, respectively. We used adjunctive endosaccular coil embolization for 88 aneurysms (66.2%). A total of 113 aneurysms (85%) were angiographically followed up 6 months following the procedure, and 93 aneurysms (69.9%) were followed up for 1 year. Results: The angiographic outcome at 6 months showed that 94 (83.2%) aneurysms had O'Kelly-Marotta (OKM) grade D, 6 (5.3%) had C, 10 (8.8%) had B, and 3 (2.7%) had A. At 1 year, 82 (88.2%) aneurysms had OKM grade D, 6 (6.5%) had C, 3 (3.2%) had B, and 2 (2.2%) had A. Multivariate analysis showed that aneurysm neck size and adjunctive coiling were statistically significant in aneurysm occlusion status. Major morbidity modified Rankin Scale >2 and mortality rates related to procedures were 3.0% and 0%, respectively. Delayed aneurysm ruptures were not observed. Conclusion: These results reveal that PED treatment of intradural ICA aneurysms is safe and efficacious. The combined use of adjunctive coil embolization not only prevents delayed aneurysm ruptures but also contributes to an increase in the rate of complete occlusion.

5.
Neurol Med Chir (Tokyo) ; 63(2): 58-64, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36543205

RESUMO

The flow diverter has been shown to be a safe and effective device for large cerebral aneurysms in the proximal internal carotid artery (ICA). Recently, its indication has been expanded to small- and medium-sized cerebral aneurysms in the distal segment of the ICA. In this study, we report a single-center, retrospective investigation of the safety and efficacy of the Pipeline Flex device to treat these aneurysms. Of the patients who underwent Pipeline implantation for small- and medium-sized ICA aneurysms (≤12 mm) at our hospital between July 2013 and October 2021, 102 patients with 104 aneurysms were included in this study. The mean age of the patients was 57.7 ± 12.1 years, and 94 (90.4%) were female. The mean aneurysmal dome diameter was 9.2 ± 2.3 mm, the mean neck diameter was 5.3 ± 1.6 mm, and the mean dome-to-neck ratio was 1.8 ± 0.5. Twenty-five patients (24.0%) had incorporated vessels from the aneurysm. Complete occlusion of the aneurysms was obtained in 96 patients (92.3%). There were no cases of parent artery stenosis or major stroke after the procedure. Absence of incorporated vessel from the aneurysm dome and adjunctive coil embolization are statistically significant factors indicating complete occlusion in multivariate analysis. The time to complete occlusion was determined earlier with the use of the Pipeline Shield (p = 0.0386) and with adjunctive coils (p = 0.0025). We showed that Pipeline implantation for small- and medium-sized aneurysms was safe and highly effective.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Estudos Prospectivos , Stents , Angiografia Cerebral/métodos
6.
Neurol Med Chir (Tokyo) ; 62(10): 451-457, 2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-36070961

RESUMO

As of January 2021, the Surpass Streamline (SS) is the most recently approved flow diverter in Japan. A total of 28 Japanese patients, including 9 clinical trial patients, with 28 large or giant unruptured internal carotid artery (ICA) aneurysms, underwent SS embolization at Juntendo University Hospital. Procedural failure occurred in two patients due to the difficulty to navigate the device in the tortuous parent artery. Therefore, 26 patients with 26 aneurysms were available for clinical and anatomical assessments. Patients' mean age was 62.6 years (range 46-86), and 24 patients (92.3%) were female. Mean aneurysm size and neck width were 15.4 mm and 7.7 mm, respectively, with 20 saccular and 6 fusiform aneurysms. Seven aneurysms were symptomatic due to the aneurysmal mass effect. Twenty patients underwent a 6-month follow-up angiography to evaluate the degree of occlusion. Anatomical outcomes were 12 (60%) complete occlusion (CO), 4 (20%) residual neck (RN), and 4 (20%) residual aneurysm. Favorable aneurysm occlusion consisted of CO, and RN was achieved in 16 (80.0%). There were no significant device stenoses. Aneurysmal mass effect improved in one and was unchanged in eight patients. There were three device-related complications, namely, delayed aneurysm rupture, minor ischemic stroke, and device occlusion (11.5%). One patient with minor ischemic stroke fully recovered before 30 days, and our series showed 7.7% risk of major ipsilateral stroke and neurological death at 30 days. The SS embolization for large and giant unruptured ICA aneurysms offers satisfactory anatomical and clinical outcomes with a low risk of device-related complications.


Assuntos
Doenças das Artérias Carótidas , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Doenças das Artérias Carótidas/etiologia , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Ensaios Clínicos como Assunto , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/etiologia , Aneurisma Intracraniano/terapia , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
7.
Cancers (Basel) ; 14(11)2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35681626

RESUMO

Clinically, early-stage oral cancers are difficult to distinguish from oral potentially malignant disorders (OPMDs), and invasive tissue biopsy should be performed to determine a treatment strategy. Previously, we focused on gargle fluid as a noninvasive testing method and reported aberrant methylation in gargle fluid in patients with oral cancer. This study aimed to distinguish early-stage oral cancer from clinically diagnosed OPMDs using gargle fluid samples. We collected gargle fluid samples from 40 patients who were clinically diagnosed with OPMDs in the training set; among them, 9 patients were pathologically diagnosed with oral cancer. Methylation levels of 25 tumor suppressor genes were analyzed using the methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA) method. We found that a combination of six genes (TP73, CASP8, RARB, KLLN, GSTP1, and CHFR) could distinguish oral cancer from clinically diagnosed OPMDs with high diagnostic performance (area under the curve [AUC], 0.885; sensitivity, 77.8%; and specificity, 87.1%). Additionally, the panel comprised of the six methylated genes was validated in the test set. Furthermore, when compared with cytology testing, the panel could accurately detect oral cancer. The present methylated gene panel may serve as a novel biomarker for oral cancer.

8.
Clin Neurol Neurosurg ; 217: 107275, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35525104

RESUMO

OBJECTIVE: Y-stent-assisted coil embolization is indicated for the treatment of complex intracranial bifurcation aneurysms. However, the long-term outcomes associated with this technique remain unclear. The purpose of this study was to evaluate the long-term outcomes of Y-stent-assisted coil embolization using the Low-profile Visualized Intraluminal Support Junior (LVIS Jr) device. METHODS: We retrospectively reviewed our databases to identify patients treated with Y-stent-assisted coiling using LVIS Jr. Digital subtraction angiography, silent magnetic resonance angiography (MRA), and time-of-flight MRA were performed at 1 year after the procedure. Patients also received an annual follow-up using MRA. Aneurysm occlusion status was classified into complete occlusion (CO), neck remnant (NR), and body filling (BF). Clinical outcomes were assessed using the modified Rankin Scale. RESULTS: Twenty-one patients (22 aneurysms) were included in this study. All procedures were performed successfully. Immediate postprocedural angiograms showed CO in 13 aneurysms (59.1%), NR in two aneurysms (9.1%), and BF in seven aneurysms (31.8%). One-year follow-up angiograms revealed CO in 86.4% of patients. Only one patient had a major recurrence and required retreatment. The mean follow-up duration was 43.5 months. The last angiographic studies demonstrated CO in 18 aneurysms (81.8%), NR in three aneurysms (13.6%), and BF in one aneurysm (4.5%). Periprocedural and delayed complications occurred in two patients and one patient, respectively. There was no permanent morbidity or death. The modified Rankin Scale scores at last clinical follow-up were equal to those before the procedures in all patients. CONCLUSION: Y-stent-assisted coil embolization using LVIS Jr for intracranial bifurcation aneurysms has favorable long-term angiographic and clinical outcomes.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento
9.
J Neuroendovasc Ther ; 16(4): 198-203, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37502453

RESUMO

Objective: Cervical dislocated fractures frequently cause vertebral artery injury (VAI), which, in turn, propagates the thrombus at the site of injury. Cerebral embolism due to a thrombus after the reduction of dislocation leads to a poorer neurological outcome. Therefore, we investigated the outcome of treatment for cervical dislocated fractures and the usefulness of parent artery occlusion (PAO) before reduction. Methods: Eight patients with cervical dislocated fractures with a locked facets treated at our hospital between January 2018 and December 2020 were evaluated. We retrospectively examined patient characteristics and clinical outcomes. Results: Among the eight patients, two were injured at C4/5, four at C5/6, and two at C6/7. All patients had locked facets. Four patients had bilateral dislocation, while the others had unilateral dislocation. Two patients with unilateral dislocation had ipsilateral vertebral artery occlusion (VAO), while the other six did not. Both patients with VAO underwent PAO to prevent cerebral embolism before reduction. The six patients who did not have VAI underwent reduction without preprocedural treatment. No cerebral ischemic complications were observed. One patient died due to paralysis of the respiratory muscles caused by spinal cord injury but the remaining seven recovered well. Conclusion: PAO before reduction for cervical dislocated fractures with VAO may be effective in preventing cerebral embolism after reduction.

10.
Neurol Med Chir (Tokyo) ; 62(1): 19-27, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-34707069

RESUMO

Flow diverter (FD) therapy using Pipeline embolization device (PED) has become an important alternative to treat internal carotid artery (ICA) aneurysms. Herein, we report the long-term outcome for 3 years after FD therapy using PED for ICA aneurysms in Japan. The patients who underwent angiographical and/or clinical follow-up for 3 years after the FD therapy using PED of large or giant unruptured ICA aneurysms from December 2012 at our university hospital are the subjects of this study. We retrospectively reviewed the in- and outpatients' medical charts, and written operative and radiological records. There were 84 patients with 90 aneurysms who could be clinically and/or angiographically followed up for 3 years. Of these, 7 aneurysms were only available for clinical follow-up. Of the remaining 83 aneurysms, 6 aneurysms had vessel occlusion due to stent thrombosis or parent artery occlusion, and 60 of the remaining 77 (77.9%) had complete occlusion. In multivariate analysis, older age (>70 years), wide neck, and non-adjunctive coiling contributed statistically significantly to incomplete occlusion. Of the 84 patients, 2 patients (2.4%) had delayed complications between 6 months and 3 years after the initial FD placement. Three patients (3.6%) had poor outcome due to postoperative major stroke complications, 2 of which were acute complications. The long-term results after FD therapy are good both angiographically and clinically. Endothelialization of the aneurysmal neck and intra-aneurysmal thrombosis contribute to complete occlusion. The primary reason for the somewhat low complete occlusion in Japan may be the patients are generally older.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Idoso , Artéria Carótida Interna/diagnóstico por imagem , Embolização Terapêutica/efeitos adversos , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Japão , Estudos Retrospectivos , Stents , Resultado do Tratamento
11.
Neuroradiol J ; 35(1): 77-85, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34187225

RESUMO

PURPOSE: Among all stents available for neuroendovascular therapy, the low-profile visible intraluminal support stent bears the highest metal coverage ratio. We deployed a low-profile visible intraluminal support stent with a delivery wire or/and microcatheter system push action to shorten the low-profile visible intraluminal support stent and thus achieve a flow diversion effect. We report our single-institution experience with the use of low-profile visible intraluminal support stents for intentionally shortened deployment (shortening group) and non-shortened deployment (non-shortening group) for unruptured intracranial aneurysms. METHODS: We retrospectively reviewed the medical records of 130 patients with 131 intracranial aneurysms who were treated with low-profile visible intraluminal support stent-assisted coil embolization from February 2016-January 2019. All perioperative complications were noted. Every 6 months, we re-examined the patients with cerebral angiography or magnetic resonance angiography. The outcomes of aneurysm occlusion were evaluated by the modified Raymond-Roy occlusion classification. We used the finite element method and computational fluid dynamics to investigate the hemodynamics after shortened low-profile visible intraluminal support stent deployment. RESULTS: Immediately after treatment, the modified Raymond-Roy occlusion classification was significantly better in the shortening group than in the non-shortening group (p<0.05). The latest angiographic outcomes showed the same tendency. Hemodynamic analysis by computational fluid dynamics suggested an adequate flow diversion effect with the use of our intentional shortening method. CONCLUSIONS: Stent-assisted coil embolization using this technique showed good results of a high complete occlusion rate and low complication rate. These findings suggest that shortened low-profile visible intraluminal support stent deployment yields a flow diversion effect and may lead to early intra-aneurysmal thrombus formation.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Prótese Vascular , Angiografia Cerebral , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento
12.
Nutrients ; 13(12)2021 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-34959928

RESUMO

Few studies have investigated the relationship between nutritional status and comprehensive assessment of oral hypofunction, especially protein intake-related sarcopenia. Thus, we explored these relationships in a large-scale cross-sectional cohort study using the seven-item evaluation for oral hypofunction and Diet History Questionnaire for nutritional assessment. We used the data from 1004 individuals who participated in the 2019 health survey of the residents of Tarumizu City, Kagoshima Prefecture, Japan for analysis. We found that individuals with oral hypofunction were significantly older with a lower skeletal muscle index. Although there were few foods that had a significant difference between the groups with and without oral hypofunction, the consumption of beans and meats was significantly lower in women and men in the oral hypofunction group, respectively. According to the lower limit of the tentative dietary goal defined in Japan, comprehensive evaluation of oral hypofunction was significantly and independently associated with protein intake in both men and women (odds ratio, 1.70; 95% confidence interval, 1.21-2.35). In conclusion, we found that oral hypofunction was associated with targeted protein intake for sarcopenia and frailty prevention in middle-aged and older community-dwelling adults. Comprehensive evaluation of oral function with intervention in cases of hypofunction could inform clinicians to better prevent sarcopenia.


Assuntos
Proteínas Alimentares/administração & dosagem , Ingestão de Alimentos/fisiologia , Fragilidade/etiologia , Fragilidade/prevenção & controle , Vida Independente , Mastigação , Doenças da Boca/complicações , Avaliação Nutricional , Sarcopenia/etiologia , Sarcopenia/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Estudos Transversais , Fabaceae , Feminino , Humanos , Japão , Masculino , Carne , Pessoa de Meia-Idade , Doenças da Boca/fisiopatologia , Inquéritos e Questionários
13.
NMC Case Rep J ; 8(1): 33-37, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34012746

RESUMO

The authors report a rare autopsy case. A 59-year-old woman underwent flow diverter (FD) therapy using a pipeline embolization device (PED) for a large paraclinoid internal carotid artery aneurysm. Follow-up magnetic resonance (MR) examinations were performed 6 months after the treatment. Although the T2-weighted images showed progressive thrombosis of the aneurysm, the silent MR angiography (MRA) clearly showed the residual blood flow within the aneurysm. The patient committed suicide 2 months after the follow-up MR examinations. An autopsy specimen showed a small section of the defective membranes with the PED that matched the entry point of residual blood flow seen clearly in the silent MRA. Macroscopic photograph and hematoxylin and eosin stained sections showed defective endothelialization. In contrast, complete endothelialization was observed in membranes covering the PED. The autopsy findings after FD therapy showed defective endothelialization that perfectly matched and corroborated the silent MRA findings.

14.
J Clin Med ; 10(8)2021 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-33921265

RESUMO

Oral hypofunction is a new concept that addresses the oral function of older adults. Few studies have investigated the relationship between oral hypofunction and general health conditions such as frailty, sarcopenia, and mild cognitive impairment. This paper explores these relationships in a large-scale, cross-sectional cohort study. The relationships of oral hypofunction with frailty, sarcopenia, and mild cognitive impairment were examined using data from 832 individuals who participated in the 2018 health survey of the residents of Tarumizu City, Kagoshima Prefecture, Japan. Individuals with frailty, sarcopenia, and mild cognitive impairment had significantly higher rates of oral hypofunction. Frailty was independently associated with deterioration of the swallowing function (odds ratio 2.56; 95% confidence interval, 1.26-5.20), and mild cognitive impairment was independently associated with reduced occlusal force (odds ratio 1.48; 95% confidence interval, 1.05-2.08) and decreased tongue pressure (odds ratio 1.77; 95% confidence interval, 1.28-2.43). There was no independent association found between sarcopenia and oral function. In conclusion, early intervention for related factors such as deterioration of the swallowing function in frailty, reduced occlusal force, and decreased tongue pressure in mild cognitive impairment could lead to the prevention of general hypofunction in older adults.

15.
Neurosci Res ; 170: 314-321, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33309864

RESUMO

Pioglitazone (PGZ), a PPARγ agonist, has been used for diabetic patients as an insulin-sensitizing agent. Recent studies have demonstrated that PGZ increases adiponectin (APN) levels and provides vascular protection in ischemic conditions. This study was designed to assess the neuroprotective effects of PGZ against cerebral ischemia-reperfusion injury via an APN-related mechanism. Type 2 diabetic leptin-deficient mice (db/db) were administered PGZ for 1 week, and plasma insulin and APN levels were measured. These mice received a middle cerebral artery occlusion and reperfusion injury, and they were evaluated for the infarct volume and by immunohistochemistry and western blotting analysis at several time points after ischemia. PGZ-administered db/db mice showed improved insulin sensitivity, and the hemorrhagic rate and infarct volume were decreased (P < 0.05). In the PGZ-administered group, plasma APN levels increased compared with the vehicle group. In the db/db group, PGZ administration significantly suppressed inflammatory reactions and oxidative stress after reperfusion (P < 0.05). PGZ may be applicable for acute cerebral ischemia treatment in metabolic syndrome patients as well as antidiabetic agents.


Assuntos
Isquemia Encefálica , Diabetes Mellitus Tipo 2 , Adiponectina , Animais , Isquemia Encefálica/complicações , Isquemia Encefálica/tratamento farmacológico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Humanos , Infarto da Artéria Cerebral Média/complicações , Infarto da Artéria Cerebral Média/tratamento farmacológico , Camundongos , Pioglitazona
16.
J Clin Neurosci ; 80: 87-91, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33099374

RESUMO

Authors reported the anatomical and clinical results of the stent assisted coiling (SAC) of unruptured middle cerebral artery (MCA) aneurysms using Low-profile Visualized Intraluminal Support Junior (LVIS Jr.). Forty-seven MCA aneurysms in 46 patients were the subjects of this study. The mean aneurysm size, neck width were 4.5 ± 1.8 mm, 3.0 ± 1.0 mm, respectively. Immediate anatomical outcomes were class Ⅰ in 31 (65.0%), class Ⅱ in 5 (10.6%) and class III in 11 (23.4%) patients according to Raymond-Roy classification. The latest anatomical outcomes were class Ⅰ in 33 (86.8%), class Ⅱ in 2 (5.3%) and class III in 3 (7.9%) patients. The change of aneurysm obliteration status were unchanged in 27 (71.0%), improved in 9 (23.7%) and worsen in 2 (5.3%). There were no recurrence necessitating additional treatment. Two patients suffered from angiographically evident in-stent thrombosis, but their clinical outcomes remain good. The modified Rankin scale at discharge were 0 in 45 patients, 1 in 1 patient. No patient showed clinical worsening during the clinical follow-up period at outpatient clinic (mean, 27.4 months). SAC of unruptured MCA aneurysms using LVIS Jr. provide safe and durable effect with high complete obliteration rate recurrence rate.


Assuntos
Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
17.
Biomed Res Int ; 2019: 4834535, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31886218

RESUMO

Coiling and clipping are standard treatment strategies for cerebral aneurysms. Regardless of the strategy used, recanalization may affect the patient's prognosis. The aim of this study was to histologically and morphologically compare the tissue proliferation after coil embolization using bare platinum coils versus second-generation hydrogel coils (HydroSoft/HydroFrame; MicroVention, Inc., Aliso Viejo, CA, USA). Endothelial-like cell proliferation was seen in both groups at 2 weeks after surgery. Macroscopic findings showed a tighter layer at 4 weeks in the hydrogel coil group, and histological and immunohistochemical findings revealed endothelial cell proliferation. This layer became much thicker and tighter at 4 weeks after surgery. Aneurysms treated with second-generation hydrogel coils may be more stable and have a lower incidence of recanalization than those treated with bare platinum coils because of the tight endothelial layer proliferation.


Assuntos
Proliferação de Células , Embolização Terapêutica , Células Endoteliais , Aneurisma Intracraniano , Animais , Modelos Animais de Doenças , Células Endoteliais/metabolismo , Células Endoteliais/ultraestrutura , Imuno-Histoquímica , Aneurisma Intracraniano/metabolismo , Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/terapia , Microscopia Eletrônica de Transmissão , Suínos
18.
J Neuroradiol ; 43(1): 43-50, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26024771

RESUMO

BACKGROUND AND PURPOSE: Recanalization of post-embolization cerebral aneurysms remains a serious problem that influences treatment outcomes. Matrix2 is a bioactive, bio-absorbable, detachable coil that was developed to reduce the risk of recanalization. We examined the short-term efficacy of the Matrix2 coil system, and evaluated the temporal profile of tissue proliferation in a swine experimental aneurysm model compared with the bare platinum (BP) coil. MATERIALS AND METHODS: Thirty-six experimental aneurysms were created in 18 swine. All aneurysms were tightly packed with Matrix2 or BP coils. Comparative histologic and morphologic analyses were undertaken 1, 2 and 4 weeks post-embolization. RESULTS: Endothelial-like cells were observed partially lining the aneurysmal opening one week post-embolization with both coil types. At two and four weeks post-embolization, the aneurysms treated with Matrix2 coils had more extensive areas of organized thrombus than those packed with BP coils, but the numbers of functional proliferating endothelial cells identified by immunohistochemistry in the tissue were broadly comparable between the groups. Moreover, morphological analysis suggested there were more mature endothelial cells in aneurysms treated with bare platinum rather than Matrix2 coils. CONCLUSIONS: Our results indicate that aneurysms embolized with Matrix2 coils build thicker scaffolds for endothelialization, but this is not necessarily evidence of earlier tissue proliferation and maturation than those embolized with BP coils. Matrix2 coils may not be superior to BP coils for preventing aneurysmal recanalization after endovascular treatment of cerebral aneurysms.


Assuntos
Proliferação de Células , Embolização Terapêutica/instrumentação , Células Endoteliais/fisiologia , Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/terapia , Animais , Materiais Biocompatíveis , Embolização Terapêutica/métodos , Procedimentos Endovasculares , Feminino , Aneurisma Intracraniano/cirurgia , Masculino , Platina , Suínos
19.
J Med Assoc Thai ; 99 Suppl 3: S1-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29901330

RESUMO

Intracranial aneurysm is major vascular disease which is life-threatening and challenging treatment. Detachable coil is one of the standard treatments. Because of little knowledge about it, the detachable coils were evaluated by various methods. Animal aneurysm models were also used to test this equipment. In the present study, sidewall aneurysms were created on common carotid arteries of Landrace-Yorkshire-Durocswine. External jugular vein grafts were used as aneurysm sac. End-to-side anastomosis was done. Ten aneurysms were created successfully in 5 swine. There is no perioperative death. This animal aneurysm model is appropriated for coil testing especially in the histopathology aspect.


Assuntos
Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Stents/normas , Animais , Modelos Animais de Doenças , Teste de Materiais/instrumentação , Teste de Materiais/métodos , Suínos
20.
Biomed Res Int ; 2014: 861632, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25028667

RESUMO

Adrenomedullin was originally isolated from pheochromocytoma cells and reduces insulin resistance by decreasing oxidative stress. White matter lesions induced by aging and hyperglycemia play a crucial role in cognitive impairment in poststroke patients. Here, we examine whether adrenomedullin deficiency and aging exacerbate ischemic white matter injury after prolonged cerebral hypoperfusion. Adrenomedullin heterozygous, wild-type young/aged mice were subjected to prolonged hypoperfusion. Prolonged cerebral hypoperfusion followed by immunohistochemical analysis was used to evaluate white matter injury. After prolonged hypoperfusion, white matter damage progressed in a time-dependent manner in AM(+/-) group compared with the wild-type group. The number of oligodendrocyte progenitor cells gradually increased after prolonged hypoperfusion, whereas oligodendrocytes decreased following a transient increase, but the ratio of increase was mild in the AM(+/-) group (P < 0.05). Oxidative stress was detected in oligodendrocytes, with a larger increase in the AM(+/-) group (P < 0.05). Aged mice showed the same tendency, but white matter damage was worse, especially in the aged AM(+/-) group. Our results demonstrated that white matter injury was increased in adrenomedullin deficiency, which induced oxidative stress. White matter injury was more exacerbated because of hyperglycemia in aged AM(+/-) group. Adrenomedullin may be an important target in the control of ischemic white matter injury.


Assuntos
Adrenomedulina/deficiência , Envelhecimento/metabolismo , Hipóxia-Isquemia Encefálica/metabolismo , Células-Tronco Neurais/metabolismo , Oligodendroglia/metabolismo , Substância Branca/lesões , Adrenomedulina/genética , Envelhecimento/genética , Animais , Doença Crônica , Hipóxia-Isquemia Encefálica/patologia , Masculino , Camundongos , Camundongos Mutantes , Células-Tronco Neurais/patologia , Oligodendroglia/patologia , Substância Branca/metabolismo , Substância Branca/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...