Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(13)2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-39001139

RESUMO

The paper "Using Absorption Models for Insulin and Carbohydrates and Deep Leaning to Improve Glucose Level Predictions" (Sensors2021, 21, 5273) proposes a novel approach to predicting blood glucose levels for people with type 1 diabetes mellitus (T1DM). By building exponential models from raw carbohydrate and insulin data to simulate the absorption in the body, the authors reported a reduction in their model's root-mean-square error (RMSE) from 15.5 mg/dL (raw) to 9.2 mg/dL (exponential) when predicting blood glucose levels one hour into the future. In this comment, we demonstrate that the experimental techniques used in that paper are flawed, which invalidates its results and conclusions. Specifically, after reviewing the authors' code, we found that the model validation scheme was malformed, namely, the training and test data from the same time intervals were mixed. This means that the reported RMSE numbers in the referenced paper did not accurately measure the predictive capabilities of the approaches that were presented. We repaired the measurement technique by appropriately isolating the training and test data, and we discovered that their models actually performed dramatically worse than was reported in the paper. In fact, the models presented in the that paper do not appear to perform any better than a naive model that predicts future glucose levels to be the same as the current ones.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Insulina , Insulina/metabolismo , Humanos , Glicemia/metabolismo , Glicemia/análise , Diabetes Mellitus Tipo 1/metabolismo , Carboidratos/química , Modelos Biológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...