Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 32(8): 947-56, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21425176

RESUMO

A design for a passive, air-breathing microfluidic fuel cell utilizing formic acid (FA) as a fuel is described and its performance characterized. The fuel cell integrates high surface area platinum (cathode) and palladium-platinum (anode) alloy electrodes within a PDMS microfluidic network that keeps them fully immersed in a liquid electrolyte. The polymer network that comprises the device also serves as a self-supporting membrane through which FA and oxygen are supplied to the alloy anode and cathode, respectively, by passive permeation from external sources. The cell is based on a planar form-factor and in its operation exploits FA concentration gradients that form across the PDMS membrane. These latter gradients allow the device to operate stably, producing a nearly constant limiting power density of ~0.2 mW/cm², without driven laminar flow of fluids or the incorporation of an in-channel separator between the anodic and the cathodic compartments. The power output of this elementary device in air is subject to electrolyte mass transport impacts, which can be reduced for a given design rule by decreasing the internal ohmic resistance of the cell. The results suggest that operational stability can be improved by decreasing the kinetic losses imposed on the cathode side of the cell due to FA crossover and modalities for doing so, such as by increasing the efficiency of fuel capture at the anode.


Assuntos
Formiatos/química , Técnicas Analíticas Microfluídicas/instrumentação , Dimetilpolisiloxanos/química , Eletrodos , Ácidos Sulfúricos/química
2.
Anal Chem ; 79(23): 9014-21, 2007 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-17973402

RESUMO

This work describes an integrated microfluidic (mu-fl) device that can be used to effect separations that discriminate single-nucleotide polymorphisms (SNP) based on kinetic differences in the lability of perfectly matched (PM) and mismatched (MM) DNA duplexes during alkaline dehybridization. For this purpose a 21-base single-stranded DNA (ssDNA) probe sequence was immobilized on agarose-coated magnetic beads, that in turn can be localized within the channels of a poly(dimethylsiloxane) microfluidic device using an embedded magnetic separator. The PM and MM ssDNA targets were hybridized with the probe to form a mixture of PM and MM DNA duplexes using standard protocols, and the hydroxide ions necessary for mediating the dehybridization were generated electrochemically in situ by performing the oxygen reduction reaction (ORR) using O2 that passively permeates the device at a Pt working electrode (Pt-WE) embedded within the microfluidic channel system. The alkaline DNA dehybridization process was followed using fluorescence microscopy. The results of this study show that the two duplexes exhibit different kinetics of dehybridization, rate profiles that can be manipulated as a function of both the amount of the hydroxide ions generated and the mass-transfer characteristics of their transport within the device. This system is shown to function as a durable platform for effecting hybridization/dehybridization cycles using a nonthermal, electrochemical actuation mechanism, one that may enable new designs for lab-on-a-chip devices used in DNA analysis.


Assuntos
Eletroquímica/métodos , Microfluídica/instrumentação , Polimorfismo de Nucleotídeo Único , Sequência de Bases , Primers do DNA , Hibridização de Ácido Nucleico
3.
Lab Chip ; 6(3): 353-61, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16511617

RESUMO

We describe an advanced microfluidic hydrogen-air fuel cell (FC) that exhibits exceptional durability and high performance, most notably yielding stable output power (>100 days) without the use of an anode-cathode separator membrane. This FC embraces an entirely passive device architecture and, unlike conventional microfluidic designs that exploit laminar hydrodynamics, no external pumps are used to sustain or localize the reagent flow fields. The devices incorporate high surface area/porous metal and metal alloy electrodes that are embedded and fully immersed in liquid electrolyte confined in the channels of a poly(dimethylsiloxane) (PDMS)-based microfluidic network. The polymeric network also serves as a self-supporting membrane through which oxygen and hydrogen are supplied to the cathode and alloy anode, respectively, by permeation. The operational stability of the device and its performance is strongly dependent on the nature of the electrolyte used (5 M H2SO4 or 2.5 M NaOH) and composition of the anode material. The latter choice is optimized to decrease the sensitivity of the system to oxygen cross-over while still maintaining high activity towards the hydrogen oxidation reaction (HOR). Three types of high surface area anodes were tested in this work. These include: high-surface area electrodeposited Pt (Pt); high-surface area electrodeposited Pd (Pd); and thin palladium adlayers supported on a "porous" Pt electrode (Pd/Pt). The FCs display their best performance in 5 M H2SO4 using the Pd/Pt anode. This exceptional stability and performance was ascribed to several factors, namely: the high permeabilities of O2, H2, and CO2 in PDMS; the inhibition of the formation of insoluble carbonate species due to the presence of a highly acidic electrolyte; and the selectivity of the Pd/Pt anode toward the HOR. The stability of the device for long-term operation was modeled using a stack of three FCs as a power supply for a portable display that otherwise uses a 3 V battery.


Assuntos
Fontes de Energia Elétrica , Hidrogênio/química , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Ar , Eletroquímica , Eletrodos , Desenho de Equipamento , Sensibilidade e Especificidade , Fatores de Tempo
4.
Lab Chip ; 5(6): 634-45, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15915256

RESUMO

We describe the fabrication and performance of an integrated microelectrochemical reactor-a design possessing utility for multiple applications that include electrochemical sensing, the generation and manipulation of in-channel microfluidic pH gradients, and fluid actuation and flow. The device architecture is based on a three-electrode electrochemical cell design that incorporates a Pt interdigitated array (IDA) working (WE), a Pt counter (CE), and Ag pseudo-reference (RE) electrodes within a microfluidic network in which the WE is fully immersed in a liquid electrolyte confined in the channels. The microchannels are made from a conventional poly(dimethylsiloxane)(PDMS) elastomer, which serves also as a thin gas-permeable membrane through which gaseous reactants in the external ambient environment are supplied to the working electrode by diffusion. Due to the high permeability of oxygen through PDMS, the microfluidic cell supports significantly (>order of magnitude) higher current densities in the oxygen reduction reaction (ORR) than those measured in conventional (quiescent) electrochemical cells for the same electrode areas. We demonstrate in this work that, when operated at constant potential under mass transport control, the device can be utilized as a membrane-covered oxygen sensor, the response of which can be tuned by varying the thickness of the PDMS membrane. Depending on the experimental conditions under which the electrochemical ORR is performed, the data establish that the device can be operated as both a programmable pH gradient generator and a microfluidic pump.


Assuntos
Dimetilpolisiloxanos/química , Microfluídica/instrumentação , Oxigênio/química , Difusão , Eletroquímica , Eletrodos , Desenho de Equipamento , Concentração de Íons de Hidrogênio , Microfluídica/métodos , Platina/química , Sensibilidade e Especificidade , Prata/química , Propriedades de Superfície , Fatores de Tempo
5.
Langmuir ; 20(17): 6974-6, 2004 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-15301473

RESUMO

We describe the fabrication and performance of a passive, microfluidics-based H2-O2 microfluidic fuel cell using thin film Pt electrodes embedded in a poly(dimethylsiloxane) (PDMS) device. The electrode array is fully immersed in a liquid electrolyte confined inside the microchannel network, which serves also as a thin gas-permeable membrane through which the reactants are fed to the electrodes. The cell operates at room temperature with a maximum power density of around 700 microW/cm(2), while its performance, as recorded by monitoring the corresponding polarization curves and the power density plots, is affected by the pH of the electrolyte, its concentration, the surface area of the Pt electrodes, and the thickness of the PDMS membrane. The best results were obtained in basic solutions using electrochemically roughened Pt electrodes, the roughness factor, R(f), of which was around 90 relative to a smooth Pt film. In addition, the operating lifetime of the fuel cell was found to be longer for the one using higher surface area electrodes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...