1.
J Orthop ; 35: 115-119, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36467427

RESUMO

Background: Parallax is poorly understood and can mislead surgeons using intraoperative fluoroscopy (IF) to guide cup placement during anterior approach (AA) total hip arthroplasty. The purpose of this study was to examine how changes in fluoroscopic beam positioning in relation to the hip and pelvis affects the projected acetabular image. Methods: An acetabular component was positioned in an anatomic pelvis model in 45° and 20° of abduction and anteversion, respectively using a computer assisted cup targeting system. Fluoroscopic images were taken at various caudal and cranially directed angles with the fluoroscopic beam centered over the hip then pelvis. In each position, four independent observers measured the abduction and anteversion angles of the projected cup image using the same computer targeting system. Results: Cup abduction and anteversion measured 43.5° and 19.5° when IF was centered over the hip and 40.5 and 27.5° when centered over the pelvis in the neutral position. Increasing the caudal direction of the beam 20° increased the projected abduction/anteversion angles by approximately 7°/12° and 9°/16° when centered over the hip and pelvis respectively. Increasing the cranial direction of the beam 20° decreased the measured abduction/anteversion angles by roughly 4°/20° and 4°/24° when centered over the hip and pelvis, respectively. Conclusion: The projected image of the acetabular component can change dramatically depending on fluoroscopic beam position relative to the hip and pelvis. Recognizing the approximate direction and magnitude of change with differing fluoroscopy positions may help surgeons avoid cup malpositioning.

2.
Tech Vasc Interv Radiol ; 19(4): 262-272, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27993321

RESUMO

Peripheral lymphedema is a chronic progressive and debilitating disorder that results from abnormal lymphatic drainage. Advances in microsurgical techniques have led to the development of new treatment options for lymphedema that benefit from preoperative imaging to select the most appropriate surgical repair. Magnetic resonance (MR) lymphangiography is a noninvasive imaging modality capable of providing high-resolution 3D images of the lower extremities to define the severity and extent of lymphedema and depict individual lymphatic channels. The MR examination consists of 2 primary sequences. The first is a 3D heavily T2-weighted sequence to depict the severity and extent of the lymphedema. The second is a fat-suppressed 3D spoiled gradient-echo sequence performed after the intracutaneous injection of an extracellular gadolinium-based MR contrast agent. As venous enhancement almost always occurs, one of the interpretative challenges is differentiating enhancing lymphatic channels from superficial veins. MR techniques that can help with venous contamination include the addition of a contrast-enhanced MR venogram to the examination protocol, or the use of an iron-based blood-pool contrast agent to selectively suppress venous enhancement.


Assuntos
Sistema Linfático/diagnóstico por imagem , Linfedema/diagnóstico por imagem , Linfografia/métodos , Imageamento por Ressonância Magnética , Adulto , Idoso , Meios de Contraste/administração & dosagem , Extremidades , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Sistema Linfático/fisiopatologia , Sistema Linfático/cirurgia , Linfedema/fisiopatologia , Linfedema/cirurgia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença
4.
Acad Radiol ; 23(5): 611-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26897602

RESUMO

RATIONALE AND OBJECTIVES: Because many patients with aortic pathology also have compromised renal function, we wished to investigate dual-energy computed tomography (DECT) aortography with 50% reduced iodine dose compared to single-energy computed tomography (SECT) aortography with standard iodine dose. MATERIALS AND METHODS: Fifty patients had DECT aortography with 50% reduced iodine dose. Thirty-four of these patients had prior SECT aortography with standard iodine dose. DECT images were reconstructed at both 50 and 77 keV and were compared to SECT 120 kVp images. Reviewers measured aortic attenuation, image noise, and scored vascular enhancement. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated. Volume CT dose index was recorded. RESULTS: Mean iodine dose was 47 g for SECT and 24 g for DECT. Aortic attenuation was highest at reduced iodine dose DECT 50 keV (570 ± 105 Hounsfield units [HU]) compared to 77 keV (239 ± 40 HU) or to standard iodine dose SECT 120 kVp (356 ± 69 HU) (P < 0.05). Image noise was greatest at 50 keV compared to 77 keV and 120 kVp (P < 0.05) but was similar between 77 keV and 120 kVp (P > 0.05). SNR and CNR were the same at 50 keV and 120 kVp (P > 0.05). Mean vascular enhancement scores were all above 3.0 (good, typical enhancement). Volume CT dose index was 11.7 mGy for DECT and 11.8 mGy for SECT (P = 0.37). CONCLUSIONS: DECT aortography with 50% reduced iodine reconstructed at 50 keV resulted in significantly greater aortic attenuation, good subjective vascular enhancement, and comparable SNR and CNR compared to standard iodine dose SECT. DECT image noise at 77 keV was similar to SECT at 120 kVp.


Assuntos
Aortografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Iodo/administração & dosagem , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Razão Sinal-Ruído , Ácidos Tri-Iodobenzoicos/administração & dosagem
5.
J Clin Imaging Sci ; 6: 52, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28123842

RESUMO

PURPOSE: The purpose of this study was to evaluate a horizontal long axis (HLA) magnetic resonance imaging (MRI) plane aligned to the long axis of the right ventricular (RV) cavity for functional analysis by comparing the measurement variability and time required for the analysis with that using a short-axis (SAX) image orientation. MATERIALS AND METHODS: Thirty-four cardiac MRI exams with cine balanced steady-state free precession image stacks in both the SAX and the HLA of the RV (RHLA) were evaluated. Two reviewers independently traced RV endocardial borders on each image of the cine stacks. The time required to complete each set of traces was recorded, and the RV end-diastolic volume, end-systolic volume, and ejection fraction were calculated. Analysis times and RV measurements were compared between the two orientations. RESULTS: Analysis time for each reviewer was significantly shorter for the RHLA stack (reviewer 1 = 6.4 ± 1.8 min, reviewer 2 = 6.0 ± 3.3 min) than for the SAX stack (7.5 ± 2.1 and 6.9 ± 3.6 min, respectively; P < 0.002). Bland-Altman analysis revealed lower mean differences, limits of agreement, and coefficients of variation for RV measurements obtained with the RHLA stack. CONCLUSIONS: RV functional analysis using a RHLA stack resulted in shorter analysis times and lower measurement variability than for a SAX stack orientation.

6.
Eur Radiol ; 26(9): 3180-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26634930

RESUMO

OBJECTIVES: Compare variability in flow measurements by phase contrast MRI, performed at different locations in the aorta and pulmonary artery (PA) using breath-held (BH) and free-breathing (FB) sequences. METHODS: Fifty-seven patients with valvular heart disease, confirmed by echocardiography, were scanned using BH technique at 3 locations in the ascending aorta (SOV = sinus of Valsalva, STJ = sinotubular junction, ASC = ascending aorta at level of right pulmonary artery) and 2 locations in PA. Single FB measurement was obtained at STJ for aorta. Obtained metrics (SV = stroke volume, FV = forward volume, BV = backward volume, RF = regurgitant fraction) were evaluated separately for patients with aortic regurgitation (AR, n = 31) and mitral regurgitation (n = 26). RESULTS: No difference was noted between the two measurements in the PA. Significant differences were noted in measured SV at different aortic locations. SV measurements obtained at ASC correlated best with the measurements obtained in the PA. Strongest correlation of AR was measured at the STJ. CONCLUSION: Measurements of flow volumes by phase contrast MRI differ depending on slice location. When using stroke volumes to calculate pulmonary to systemic blood flow ratio (Qp/Qs), ASC should be used. For quantifying aortic regurgitation, measurement should be obtained at STJ. KEY POINTS: • Aortic regurgitation can be accurately measured by MRI. • Aortic regurgitation measurement by MRI varies according to the location where measured. • Aortic regurgitation can also be measured by MRI without breath hold.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/diagnóstico , Adulto , Idoso , Suspensão da Respiração , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Curr Probl Diagn Radiol ; 45(3): 174-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26460054

RESUMO

The objective of this study was to develop and demonstrate a technique to eliminate venous enhancement in contrast-enhanced magnetic resonance lymphangiography through shortening T2(⁎) in the blood pool, thus allowing for a lymphatic-only map. Administration of the blood-pool iron agent ferumoxtyol in addition to intracutaneous gadolinium during contrast-enhanced magnetic resonance lymphangiography allows for suppression of vascular structures to achieve venous-free lymphatic mapping.


Assuntos
Meios de Contraste , Óxido Ferroso-Férrico , Gadolínio DTPA , Aumento da Imagem/métodos , Linfedema/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sangue/diagnóstico por imagem , Humanos , Linfografia/métodos , Imagens de Fantasmas
8.
J Magn Reson Imaging ; 42(6): 1465-77, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25906741

RESUMO

Lymphedema is a chronic progressive edematous disease that in the United States is most commonly related to malignancy and its treatment. Lymphaticovenular anastomosis is a recently introduced microsurgical treatment option for lymphedema that requires the identification and mapping of individual lymphatic channels. While nuclear medicine lymphoscintigraphy has been the primary imaging modality performed to evaluate suspected lymphedema, lymphoscintigraphy does not provide the spatial information necessary for presurgical planning. High-resolution dynamic 3D magnetic resonance imaging (MRI) can noninvasively image abnormal lymphatic channels to both diagnose lymphedema and depict the location and number of individual lymphatic channels for surgical planning. MR lymphangiography can be performed at 1.5T or 3.0T using multichannel phased array surface coils. The main components of the exam are a heavily T2 -weighted 3D sequence to define the severity and extent of edema, a high-resolution dynamic 3D gradient echo imaging after intracutaneous contrast injection to visualize lymphatic channels, and a delayed 3D gradient echo sequence after intravenous contrast to define veins. This article reviews the pathophysiology and microsurgical treatment of lymphedema, presents the imaging protocol used at our institution, and describes exam interpretation and the image postprocessing performed for surgical planning.


Assuntos
Excisão de Linfonodo/métodos , Linfonodos/patologia , Linfedema/patologia , Linfedema/cirurgia , Linfografia/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Imageamento Tridimensional/métodos , Linfonodos/cirurgia , Cirurgia Assistida por Computador/métodos
9.
Emerg Radiol ; 22(3): 231-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25228282

RESUMO

The definitive diagnosis of pulmonary embolism, a significant cause of morbidity and mortality, relies on imaging. In this study, we compare the conventional computed tomography pulmonary angiogram (CTPA) protocol to a double-rule out CT angiogram (DRO CTA) protocol in terms of vascular enhancement, radiation dose, and contrast volume delivered. The CTPA protocol involves injection of a timing bolus for localization of the pulmonary artery, whereas the DRO CTA protocol involves a biphasic contrast. We analyzed 248 consecutive CTPA studies and 242 consecutive DRO CTA studies. Vessel enhancement using region of interest (ROI) measurements, radiation dose delivered, and total contrast volume administered was recorded. The enhancement of all vessels measured was statistically significantly higher with the biphasic DRO CTA protocol than the CTPA protocol. The difference in mean vascular enhancement for the two protocols was greatest in the descending aorta (DA, P < 0.001) and least in the main pulmonary artery (MPA, P = 0.001). The percent of studies with vascular enhancement ≥250 Hounsfield units (HU) was significantly greater in all vascular beds except the MPA when the DRO CTA protocol was used. Studies performed with the DRO CTA protocol led to less radiation exposure and used less contrast than those performed with the CTPA protocol (P < 0.001 for both). According to the final radiology report, 35.08 % of studies in the CTPA group and 22.31 % of studies in the DRO CTA group were considered indeterminate (P = 0.001). In conclusion, the biphasic DRO CTA protocol leads to statistically significantly higher opacification of all pulmonary arterial and aortic vessels studied, with no greater delivery of radiation or contrast, than the monophasic CTPA protocol.


Assuntos
Aorta Torácica/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Iohexol/administração & dosagem , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
10.
Curr Probl Diagn Radiol ; 44(1): 8-14, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25306385

RESUMO

The purpose of this study was to assess the use of semiquantitative contrast-enhanced parameter analysis as an objective criteria for improving the magnetic resonance (MR) evaluation of hepatocellular carcinoma (HCC) in patients with cirrhosis. Contrast-enhanced MR examination findings from 19 patients with 21 pathologically proven HCC were evaluated using a dedicated liver image postprocessing workstation. Contrast-enhancement kinetic curves were created for each lesion, and 4 enhancement parameters (arterial wash-in slope, arterial-portal slope, arterial-equilibrium slope, and portal-equilibrium slope) were defined from the signal intensity-time plots. The accuracy of each enhancement parameter for the characterization of HCC was assessed. Statistical analysis revealed that an arterial-phase wash-in slope percentage value >1.35 per sec had a sensitivity of 86%, a specificity of 71%, and an accuracy of 79% for the correct characterization of HCC, whereas an arterial-equilibrium wash-out slope percentage value<0.05 per sec had a sensitivity of 86%, a specificity of 81%, and an accuracy of 83%. Although there were significant differences among all groups, the greatest accuracy for differentiation based on receiver operating curve analysis appears to be with arterial and arterial-equilibrium phases. Semiquantitative analysis of lesion contrast kinetics could provide objective parameters to improve the characterization of HCC on contrast-enhanced MR images.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Processamento de Imagem Assistida por Computador , Cirrose Hepática/diagnóstico , Neoplasias Hepáticas/diagnóstico , Fígado/patologia , Imageamento por Ressonância Magnética , Carcinoma Hepatocelular/patologia , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Aumento da Imagem , Fígado/anatomia & histologia , Cirrose Hepática/patologia , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Curva ROC , Sensibilidade e Especificidade
11.
Eur Radiol ; 25(5): 1238-46, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25537980

RESUMO

PURPOSE: We compared carotid plaque calcification detection sensitivity and apparent cross-sectional area on CT as a function of CT beam energy using conventional CT techniques and virtual mono-energetic CT images generated from dual-energy acquisitions. METHODS & MATERIALS: Five ex-vivo carotid endarterectomy (CEA) specimens were imaged with dual-energy computed tomography. Virtual monochromatic spectrum (VMS) CT images were reconstructed at energies between 40-140 keV. The same specimens were imaged using conventional polyenergetic spectrum (PS) CT with peak beam energies 80, 100, 120, and 140 kVp. The histological calcium areas on each corresponding CEA specimen were traced manually on digitized images of Toluidine-Blue/Basic-Fuchsin stained plastic sections. RESULTS: 40 keV VMS CT images provided high detection sensitivity (97 %) similar to conventional PS CT images (~96 %). The calcification size measured on CT decreased systematically with increasing CT beam energy; the rate of change was larger for the VMS images than for PS images. CONCLUSION: From a single dual-energy CT, multiple VMS-CT images can be generated, yielding equivalent detection sensitivity and size correlations as conventional PS-CT in CEA calcification imaging. VMS-CT at 80-100 keV provided the most accurate estimates of calcification size, as compared to histology, but detection sensitivity was reduced for smaller calcifications on these images. KEY POINTS: • Calcifications depicted at 80-100 keV were most similar to the histology standard. • Conventional polychromatic images demonstrated excellent correlation with plaque size at pathology. • Conventional polychromatic images systematically overestimate plaque size. • Plaque calcifications can be missed on high energy monochromatic images.


Assuntos
Placa Aterosclerótica/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Dissecação , Endarterectomia das Carótidas , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
AJR Am J Roentgenol ; 203(3): 601-6, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25148163

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effect of use of dual-energy CT monochromatic imaging in the late hepatic arterial phase on hyperenhancing focal lesion detection and lesion conspicuity. SUBJECTS AND METHODS: This prospective study included 72 patients imaged with a single-source dual-energy CT scanner. Late arterial phase imaging was performed with dual energies of 140 and 80 kVp, and the portal venous and delayed phases were performed with a single energy of 120 kVp. Two deidentified image sets were created: set A consisted of 77-keV images only, and set B consisted of 40-, 50-, 70-, and 77-keV images and iodine-based contrast material decomposition images. Two independent reviewers identified hypervascular lesions and subjectively scored lesion conspicuity. Contrast-to-noise ratios were calculated, and radiation dose (volume CT dose index) was recorded. RESULTS: The 128 lesions identified had a mean size of 1.7 ± 1.4 cm. There was no difference in lesion detection between the two reviewers or the two image sets. The contrast-to-noise ratio at 50 keV was 72% greater than that at 77 keV (p < 0.0001). Subjective conspicuity was statistically greatest at 50 keV (p < 0.0001). There was no statistical difference in mean volume CT dose index between the dual-energy (12.8 mGy) and the two single-energy (14.4 and 14.2 mGy) phases. CONCLUSION: Viewing dual-energy CT images may result in the greatest subjective lesion conspicuity and measured contrast-to-noise ratio at 50 keV with equal detection of hyperenhancing liver lesions compared with viewing 77-keV images alone. In addition, the radiation doses of dual-energy CT may be similar to those of single-energy CT.


Assuntos
Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neovascularização Patológica/diagnóstico por imagem , Lesões Pré-Cancerosas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Feminino , Humanos , Cirrose Hepática/complicações , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/etiologia , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica/etiologia , Variações Dependentes do Observador , Veia Porta/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
13.
Radiology ; 273(3): 793-800, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25170546

RESUMO

PURPOSE: To investigate whether reduced radiation dose liver computed tomography (CT) images reconstructed with model-based iterative reconstruction ( MBIR model-based iterative reconstruction ) might compromise depiction of clinically relevant findings or might have decreased image quality when compared with clinical standard radiation dose CT images reconstructed with adaptive statistical iterative reconstruction ( ASIR adaptive statistical iterative reconstruction ). MATERIALS AND METHODS: With institutional review board approval, informed consent, and HIPAA compliance, 50 patients (39 men, 11 women) were prospectively included who underwent liver CT. After a portal venous pass with ASIR adaptive statistical iterative reconstruction images, a 60% reduced radiation dose pass was added with MBIR model-based iterative reconstruction images. One reviewer scored ASIR adaptive statistical iterative reconstruction image quality and marked findings. Two additional independent reviewers noted whether marked findings were present on MBIR model-based iterative reconstruction images and assigned scores for relative conspicuity, spatial resolution, image noise, and image quality. Liver and aorta Hounsfield units and image noise were measured. Volume CT dose index and size-specific dose estimate ( SSDE size-specific dose estimate ) were recorded. Qualitative reviewer scores were summarized. Formal statistical inference for signal-to-noise ratio ( SNR signal-to-noise ratio ), contrast-to-noise ratio ( CNR contrast-to-noise ratio ), volume CT dose index, and SSDE size-specific dose estimate was made (paired t tests), with Bonferroni adjustment. RESULTS: Two independent reviewers identified all 136 ASIR adaptive statistical iterative reconstruction image findings (n = 272) on MBIR model-based iterative reconstruction images, scoring them as equal or better for conspicuity, spatial resolution, and image noise in 94.1% (256 of 272), 96.7% (263 of 272), and 99.3% (270 of 272), respectively. In 50 image sets, two reviewers (n = 100) scored overall image quality as sufficient or good with MBIR model-based iterative reconstruction in 99% (99 of 100). Liver SNR signal-to-noise ratio was significantly greater for MBIR model-based iterative reconstruction (10.8 ± 2.5 [standard deviation] vs 7.7 ± 1.4, P < .001); there was no difference for CNR contrast-to-noise ratio (2.5 ± 1.4 vs 2.4 ± 1.4, P = .45). For ASIR adaptive statistical iterative reconstruction and MBIR model-based iterative reconstruction , respectively, volume CT dose index was 15.2 mGy ± 7.6 versus 6.2 mGy ± 3.6; SSDE size-specific dose estimate was 16.4 mGy ± 6.6 versus 6.7 mGy ± 3.1 (P < .001). CONCLUSION: Liver CT images reconstructed with MBIR model-based iterative reconstruction may allow up to 59% radiation dose reduction compared with the dose with ASIR adaptive statistical iterative reconstruction , without compromising depiction of findings or image quality.


Assuntos
Hepatopatias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Adulto , Meios de Contraste , Feminino , Humanos , Iohexol , Masculino , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos Testes , Razão Sinal-Ruído
14.
Top Magn Reson Imaging ; 23(1): 51-69, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24477166

RESUMO

The purpose of this article was to review the basic properties of available gadolinium-based magnetic resonance contrast agents, discuss their fundamental differences, and explore common and evolving applications of gadolinium-based magnetic resonance contrast throughout the body excluding the central nervous system. A more specific aim of this article was to explore novel uses of these gadolinium-based contrast agents and applications where a particular agent has been demonstrated to behave differently or be better suited for certain applications than the other contrast agents in this class.


Assuntos
Meios de Contraste/química , Gadolínio/química , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Meios de Contraste/classificação , Desenho de Fármacos , Gadolínio/classificação , Humanos
15.
Radiographics ; 33(6): 1801-15, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24108563

RESUMO

As survival rates continue to increase for patients with childhood and adult malignancies, imaging utilization in these patients will likely increase substantially. It is important to detect disease recurrence and to recognize the potential complications that occur after treatment with oncologic medications and therapeutic radiation. The most common cardiotoxic side effect of the anthracycline drug class is a dose-dependent decline in ejection fraction, which may result in dilated cardiomyopathy. Multiple-uptake gated acquisition (MUGA) scanning plays an important role in diagnosis of this subclinical cardiac dysfunction. Other less common cardiotoxic side effects of chemotherapeutic medications include arrhythmia, myocarditis, coronary artery disease, tamponade, pericarditis, and pericardial effusion. Radiation therapy can also lead to cardiotoxicity when the heart or pericardium is included in the radiation portal. Radiation-induced conditions include pericardial disease, coronary artery disease, valvular disease, and cardiomyopathy. Many of these side effects are asymptomatic until late in the course of the disease. With imaging, these pathologic conditions can often be diagnosed before symptom onset, which may allow early intervention. Radiologists should be familiar with the current knowledge and pathophysiology regarding cardiac complications related to chemotherapy and radiation therapy of malignant neoplasms and the appearances of treatment-related cardiotoxicity that can be found at radiography, nuclear medicine examinations, and cross-sectional imaging. Supplemental material available at http://radiographics.rsna.org/lookup/suppl/doi:10.1148/rg.336125005/-/DC1.


Assuntos
Antineoplásicos/efeitos adversos , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/etiologia , Diagnóstico por Imagem , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia , Radioterapia/efeitos adversos , Humanos
16.
AJR Am J Roentgenol ; 200(6): W617-20, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23701092

RESUMO

OBJECTIVE: Although weight-based contrast agent injection protocols can improve contrast-enhanced CT, one disadvantage is waste caused by differences between the amount of contrast material required for a weight-based algorithm and full-package protocols used with single-use packaging of contrast material. The availability of 500-mL multiple-use packaging of contrast material should facilitate the implementation of weight-based contrast bolus protocols for CT because arbitrary volumes of contrast agent can be loaded without significant waste. Our hypothesis was that multiple-use packaging when used with a weight-based contrast bolus protocol would reduce costs compared with single-use packaging. MATERIALS AND METHODS: Contrast agent volume loaded and volume actually delivered to 1304 patients undergoing abdominal and pelvic CT were recorded. Model 1 used volume loaded to estimate contrast material cost, model 2 used volume delivered, and model 3 assumed that patients received either 100 or 150 mL from a single-use package, depending on weight. RESULTS: Model 1 required 368 packages of 500 mL contrast material ($23,000). Model 2 required 353 packages of 500 mL contrast material ($22,062.50). Model 3 required 863 and 478 packages of 100 and 150 mL contrast material, respectively ($22,120). CONCLUSION: Cost containment can be realized while improving the quality of contrast opacification by employing 500-mL multiple-use packaging of contrast materials. Care must be taken by the technologists to load only the volume of contrast agent that is needed, or the resulting contrast agent waste will negate the savings and even result in cost increases.


Assuntos
Peso Corporal , Meios de Contraste/administração & dosagem , Meios de Contraste/economia , Tomografia Computadorizada por Raios X , Algoritmos , Controle de Custos , Humanos , Embalagem de Produtos , Radiografia Torácica
17.
PLoS One ; 8(4): e61121, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23613797

RESUMO

PURPOSE: The purpose of this study was to assess the diagnostic accuracy and one year prognosis of whole chest, "multiple rule out" CT for coronary artery disease (CAD) in Emergency Department patients. METHODS AND FINDINGS: One hundred and two Emergency Department patients at low to intermediate risk of acute coronary syndrome (ACS), pulmonary embolism and/or acute aortic syndrome underwent a research 64 channel ECG-gated, whole chest CT and a standard of care evaluation. Patients were classified with obstructive CAD with either a coronary CT stenosis greater than 50% or a non-evaluable coronary segment. SOC and 3 month follow up data were used to determine an adjudicated clinical diagnosis. The diagnostic ability of obstructive CAD on CT to identify clinical diagnoses was determined. Patients were followed up for 1 year for cardiac events. Seven (7%) patients were diagnosed with ACS. CT sensitivity to detect obstructive CAD in ACS patients was 100% (95% CI 65%, 100%), negative predictive value 100% (96%, 100%), specificity 88% (80%, 94%), and positive predictive value 39% (17%, 64%). Pulmonary embolism and acute aortic syndrome were not identified in any patients. No cardiac events occurred in patients without obstructive CAD over 1 year. CONCLUSIONS: Whole chest CT has high sensitivity and negative predictive value for ACS with excellent one year prognosis in patients without obstructive CAD on CT. The frequency of pulmonary embolism or acute aortic syndrome and the higher radiation dose suggest whole chest CT should be limited to select patients. ClinicalTrials.org #: NCT00855231.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Eletrocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Síndrome Coronariana Aguda/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
18.
AJR Am J Roentgenol ; 200(5): 1071-6, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23617492

RESUMO

OBJECTIVE: The purpose of this study is to compare three CT image reconstruction algorithms for liver lesion detection and appearance, subjective lesion conspicuity, and measured noise. MATERIALS AND METHODS: Thirty-six patients with known liver lesions were scanned with a routine clinical three-phase CT protocol using a weight-based noise index of 30 or 36. Image data from each phase were reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Randomized images were presented to two independent blinded reviewers to detect and categorize the appearance of lesions and to score lesion conspicuity. Lesion size, lesion density (in Hounsfield units), adjacent liver density (in Hounsfield units), and image noise were measured. Two different unblinded truth readers established the number, appearance, and location of lesions. RESULTS: Fifty-one focal lesions were detected by truth readers. For blinded reviewers compared with truth readers, there was no difference for lesion detection among the reconstruction algorithms. Lesion appearance was statistically the same among the three reconstructions. Although one reviewer scored lesions as being more conspicuous with MBIR, the other scored them the same. There was significantly less background noise in air with MBIR (mean [± SD], 2.1 ± 1.4 HU) than with ASIR (8.9 ± 1.9 HU; p < 0.001) or FBP (10.6 ± 2.6 HU; p < 0.001). Mean lesion contrast-to-noise ratio was statistically significantly higher for MBIR (34.4 ± 29.1) than for ASIR (6.5 ± 4.9; p < 0.001) or FBP (6.3 ± 6.0; p < 0.001). CONCLUSION: In routine-dose clinical CT of the liver, MBIR resulted in comparable lesion detection, lesion characterization, and subjective lesion conspicuity, but significantly lower background noise and higher contrast-to-noise ratio compared with ASIR or FBP. This finding suggests that further investigation of the use of MBIR to enable dose reduction in liver CT is warranted.


Assuntos
Algoritmos , Artefatos , Neoplasias Hepáticas/diagnóstico por imagem , Modelos Biológicos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Interpretação Estatística de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
19.
AJR Am J Roentgenol ; 200(5): W450-7, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23617513

RESUMO

OBJECTIVE: Coronary CT angiography has high sensitivity, but modest specificity, to detect acute coronary syndrome. We studied whether adding resting CT myocardial perfusion imaging improved the detection of acute coronary syndrome. SUBJECTS AND METHODS: Patients with low-to-intermediate cardiac risk presenting with possible acute coronary syndrome received both the standard of care evaluation and a research thoracic 64-MDCT examination. Patients with an obstructive (> 50%) stenosis or a nonevaluable coronary segment on CT were diagnosed with possible acute coronary syndrome. CT perfusion was determined by applying gray and color Hounsfield unit maps to resting CT angiography images. Adjudicated patient diagnoses were based on the standard of care and 3-month follow-up. Patient-level diagnostic performance for acute coronary syndrome was calculated for coronary CT, CT perfusion, and combined techniques. RESULTS: A total of 105 patients were enrolled. Of the nine (9%) patients with acute coronary syndrome, all had obstructive CT stenoses but only three had abnormal CT perfusion. CT perfusion was normal in all other patients. To detect acute coronary syndrome, CT angiography had 100% sensitivity, 89% specificity, and a positive predictive value of 45%. For CT perfusion, specificity and positive predictive value were each 100%, and sensitivity was 33%. Combined cardiac CT and CT perfusion had similar specificity but a higher positive predictive value (100%) than did CT angiography. CONCLUSION: Resting CT perfusion using CT angiographic images may have high specificity and may improve CT positive predictive value for acute coronary syndrome without added radiation and contrast. However, normal resting CT perfusion cannot exclude acute coronary syndrome.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/epidemiologia , Angiografia Coronária/estatística & dados numéricos , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Washington/epidemiologia
20.
Eur Radiol ; 23(2): 367-74, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22907636

RESUMO

OBJECTIVE: The aim of this study was to compare the size of the calcifications measured on the different keV images to a histological standard. METHODS: Five ex vivo carotid endarterectomy (CEA) specimens were imaged with a dual-energy CT. CT images were reconstructed at different monochromatic spectral energies (40, 60, 77, 80, 100, 120, 140 keV). Cross-sectional area of the plaque calcifications present on each CT image was measured. The histological calcium areas on each corresponding CEA specimen were traced manually on digitised images of Toluidine Blue/Basic Fuchsin stained plastic sections. The CT images and corresponding histology sections were matched. The CT-derived calcium areas on each keV image were compared to the calcified area measurements by histology. RESULTS: A total of 107 histology sections were matched to corresponding CT images. The average calcified area per section by histology was 7.6 ± 7 mm(2) (range 0-26.4 mm(2)). There was no significant difference between the calcified areas measured by histology and those measured on CT-virtual monochromatic spectral (VMS) reconstructed images at 77 keV (P = 0.08), 80 keV (P = 0.20) and 100 keV (P = 0.14). CONCLUSIONS: Calcium area measured on the 80 keV image set was most comparable to the amount of calcium measured by histology.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Placa Aterosclerótica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Biópsia por Agulha , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/patologia , Estenose das Carótidas/cirurgia , Intervalos de Confiança , Endarterectomia das Carótidas/métodos , Feminino , Humanos , Imuno-Histoquímica , Masculino , Placa Aterosclerótica/patologia , Estudos de Amostragem , Sensibilidade e Especificidade , Manejo de Espécimes