1.
J Artif Organs ; 10(4): 231-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18071854

RESUMO

The rotary undulation pump is believed to be a good candidate for the next-generation artificial heart. Due to its complex movement, it is desirable to magnetically levitate the rotor and dynamically control the gap. In this article, the applicability of a fiber-optic gap sensor to the dynamic position control of the rotor in the rotary undulation pump was investigated. The fiber-optic gap sensor consisted of two plastic-core fibers and a reflection plate. Two 1-mm-diameter optical fibers were aligned parallel: one for source light propagation and the other for reflected light transmission. The basic properties of gap sensors using four different light sources were explored in five media (air, physiologic saline, and blood samples with three different hematocrit levels). The influence of the oxygen saturation level in the blood on sensing was investigated with two types of light sources. It is desirable to use a light source the wavelength of which shows similar absorption coefficients for both oxygenated blood and deoxygenated blood. The effect of the distance between the two fibers on the sensing and range was also investigated. The results indicated that the fiber-optic gap sensor is quite promising for the active control of rotor positioning in the rotary undulation pump.


Assuntos
Tecnologia de Fibra Óptica , Coração Artificial , Animais , Cabras , Hemorreologia , Magnetismo , Fibras Ópticas , Desenho de Prótese
2.
J Artif Organs ; 10(2): 60-70, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17574507

RESUMO

The development of mechanical circulatory support devices at the University of Tokyo has focused on developing a small total artificial heart (TAH) since achieving 532 days of survival of an animal with a paracorporial pneumatically driven TAH. The undulation pump was invented to meet this purpose. The undulation pump total artificial heart (UPTAH) is an implantable TAH that uses an undulation pump. To date, the UPTAH has been implanted in 71 goats weighting from 39 to 72 kg. The control methods are very important in animal experiments, and sucking control was developed to prevent atrial sucking. Rapid left-right balance control was performed by monitoring left atrial pressure to prevent acute lung edema caused by the rapid increase in both arterial pressure and venous return associated with the animal becoming agitated. Additionally, 1/R control was applied to stabilize the right atrial pressure. By applying these control methods, seven goats survived more than 1 month. The maximum survival period was 63 days. We are expecting to carry out longer term animal experiments with a recent model of TAH. In addition to the TAH, an undulation pump ventricular assist device (UPVAD), which is an implantable ventricular assist device (VAD), has been in development since 2002, based on the technology of the UPTAH. The UPVAD was implanted in six goats; three goats survived for more than 1 month. While further research and development is required to complete the the UPVAD system, the UPVAD has good potential to be realized as an implantable pulsatile-flow VAD.


Assuntos
Coração Auxiliar , Desenho de Prótese , Animais , Tóquio , Universidades