Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cataract Refract Surg ; 41(2): 295-305, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25661122

RESUMO

PURPOSE: To evaluate the safety and effectiveness of the Trulign toric intraocular lens (IOL) in adults with cataract. SETTING: Eight private practices in the United States and 1 in Canada. DESIGN: Prospective randomized single-masked multicenter study. METHODS: A toric IOL (1.25 D, 2.00 D, or 2.75 D, determined by a toric calculator) was implanted in eligible patients with age-related cataract requiring a 16.00 to 27.00 diopter (D) spherical IOL power and with a predicted postoperative astigmatism of 0.83 to 2.50 D. Eyes within the lowest cylinder range (predicted postoperative astigmatism 0.83 to 1.32 D) were randomized in a 1:1 ratio between the 1.25 D toric IOL group and the nontoric accommodating IOL (Crystalens) control group. RESULTS: The toric 1.25 D group had a statistically significantly greater percentage reduction in absolute cylinder (P < .001) and uncorrected distance visual acuity (P = .002) than the control group at the 120- to 180-day visit. The mean monocular uncorrected vision at distance, intermediate, and near was 20/25, 20/22, and 20/39, respectively, with the 1.25 D, 2.00 D, and 2.75 D toric IOLs in aggregate (toric group). In addition, 96.1% of patients (123/128) had 5.0 degrees or less absolute IOL rotation postoperatively. Regarding safety, the endpoints for preservation of corrected visual acuity and the incidence of complications and adverse events were met. CONCLUSION: The toric IOL was safe and effective in reducing the effects of preoperative corneal astigmatism and provided excellent uncorrected distance and intermediate vision and functional near vision. FINANCIAL DISCLOSURES: Dr. Pepose is a consultant to Bausch & Lomb and was medical monitor of this study. Drs. Buckhurst, Whitman, Feinerman, Hovanesian, Davies, Labor, and Carter are consultants to Bausch & Lomb. At the time of the study, Drs. Hayashida, and Khodai were employees of Bausch & Lomb. Drs. Colvard and Mittleman have financial or proprietary interest in any material or method mentioned.


Assuntos
Materiais Biocompatíveis , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Presbiopia/cirurgia , Elastômeros de Silicone , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/cirurgia , Catarata/complicações , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Presbiopia/complicações , Estudos Prospectivos , Desenho de Prótese , Refração Ocular/fisiologia , Método Simples-Cego , Resultado do Tratamento , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...