Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 25(8): 859-865, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24724724

RESUMO

INTRODUCTION: Right phrenic nerve palsy (PNP) is a typical complication of cryoballoon ablation of the right-sided pulmonary veins (PVs). Phrenic nerve function can be monitored by palpating the abdomen during phrenic nerve pacing from the superior vena cava (SVC pacing) or by fluoroscopy of spontaneous breathing. We sought to compare the sensitivity of these 2 techniques during cryoballoon ablation for detection of PNP. METHODS AND RESULTS: A total of 133 patients undergoing cryoballoon ablation were monitored with both SVC pacing and fluoroscopy of spontaneous breathing during ablation of the right superior PV. PNP occurred in 27/133 patients (20.0%). Most patients (89%) had spontaneous recovery of phrenic nerve function at the end of the procedure or on the following day. Three patients were discharged with persistent PNP. All PNP were detected first by fluoroscopic observation of diaphragm movement during spontaneous breathing, while diaphragm could still be stimulated by SVC pacing. In patients with no recovery until discharge, PNP occurred at a significantly earlier time (86 ± 34 seconds vs. 296 ± 159 seconds, P < 0.001). No recovery occurred in 2/4 patients who were ablated with a 23 mm cryoballoon as opposed to 1/23 patients with a 28 mm cryoballoon (P = 0.049). CONCLUSION: Fluoroscopic assessment of diaphragm movement during spontaneous breathing is more sensitive for detection PNP as compared to SVC pacing. PNP as assessed by fluoroscopy is frequent (20.0%) and carries a high rate of recovery (89%) until discharge. Early onset of PNP and use of 23 mm cryoballoon are associated with PNP persisting beyond hospital discharge.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Diafragma/inervação , Monitorização Intraoperatória/métodos , Paralisia/diagnóstico , Traumatismos dos Nervos Periféricos/diagnóstico , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Respiração , Adulto , Idoso , Pontos de Referência Anatômicos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Elétrica , Feminino , Fluoroscopia , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Palpação , Paralisia/diagnóstico por imagem , Paralisia/etiologia , Paralisia/fisiopatologia , Alta do Paciente , Traumatismos dos Nervos Periféricos/diagnóstico por imagem , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/fisiopatologia , Nervo Frênico/fisiopatologia , Nervo Frênico/cirurgia , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Cardiol J ; 21(4): 392-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23990193

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) has been identified as associated with the onset and propagation of atrial fibrillation (AF) and predicts recurrences of AF after pulmonary vein isolation (PVI). Vice versa, it has never been investigated whether PVI influences OSA. However, it has been controversial whether a restored atrial function can affect the course of OSA. There-fore, we have assessed whether PVI procedure modulates the prevalence and severity of OSA. METHODS AND RESULTS: We included 23 individuals with AF that were assigned to undergo PVI into this study. Patients were 65 ± 7 years old, obese (BMI 29.9 ± 5.4 kg/m²), white (100%) and had a normal left ventricular function (LVEF 64 ± 9%). Polygraphic assessment was carried out before and 6 months after PVI. The prevalence of OSA, defined as an apnea-hypopnea index (AHI) ≥ 5 per hour of sleep, was 74% before PVI compared to 70% 6 months after the procedure (p > 0.05). Severity of OSA did not differ (AHI before vs. after: 18 ± 18/h vs. 15 ± 17/h, p > 0.05) as well as further polygraphic parameters did not differ before and after the procedure. CONCLUSIONS: Prevalence and severity of OSA are not affected by PVI in patients suffering from AF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Síndromes da Apneia do Sono/epidemiologia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prevalência , Veias Pulmonares/fisiopatologia , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
3.
J Interv Card Electrophysiol ; 38(2): 107-14, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23793444

RESUMO

PURPOSE: Identification of reliable risk factors for recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI) has important implications. Left atrial (LA) pressure is a largely observator-independent parameter that can easily be determined after transseptal puncture. The purpose of this study was to investigate the predictive value of LA pressure for AF recurrence after PVI. METHODS: Two hundred five consecutive patients with paroxysmal or persistent AF scheduled for first PVI were included. Baseline clinical data were collected. During PVI, LA pressure was determined invasively after transseptal puncture. PVI was performed with radiofrequency or cryoenergy, and patients were followed for 25 ± 7 months. RESULTS: One hundred five (51 %) patients had AF recurrence. Patients with persistent AF prior to ablation had significantly more recurrences than patients with paroxysmal AF (70.1 vs. 42.0 %, p < 0.001). Mean LA pressure was significantly higher in patients with recurrence of AF (13.4 ± 7.1 vs. 11.0 ± 5.2 mmHg, p = 0.007), as was mean LA volume index (40.1 ± 18.5 vs. 33.0 ± 11.2 mL/m(2), p < 0.001). In the multivariate analysis, mean LA pressure was predictive in patients with normal or mildly enlarged LA, while AF type was not predictive. For each 1-mmHg increase in LA pressure, the risk of AF recurrence increased by 11 % in this subgroup. In patients with moderately or severely enlarged LA, AF type was predictive whereas LA pressure was not. CONCLUSION: LA pressure, AF type, and LA volume index are independent predictors for recurrence of AF after PVI. LA pressure may be helpful especially in patients with small atria, where AF type is not predictive.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Pressão Atrial , Determinação da Pressão Arterial/estatística & dados numéricos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Fibrilação Atrial/epidemiologia , Determinação da Pressão Arterial/métodos , Feminino , Alemanha/epidemiologia , Átrios do Coração , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Recidiva , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 36(2): 194-202, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23379836

RESUMO

PURPOSE: Cavotricuspid isthmus-dependent atrial flutter (AFL) can occur in a paroxysmal or persistent pattern. The aim of this study was to identify clinical, echocardiographic, and electrophysiological risk factors independently associated with persistence of AFL. METHODS: Patients of the recently published AURUM 8 study with paroxysmal versus persistent AFL were compared with respect to clinical and echocardiographic baseline characteristics as well as procedural parameters. The AURUM 8 study is a randomized, multicenter clinical trial comparing the efficacy and safety of gold versus platinum-iridium 8-mm-tip ablation. AFL was paroxysmal in 218 patients and persistent in 210 patients. RESULTS: Univariate analysis revealed that patients with persistent AFL had higher New York Heart Association class (P = 0.002), shorter time since 1st AFL episode (median 0.18 vs 0.34, P = 0.037), a higher prevalence of previous coronary artery bypass grafting surgery (17% vs 9%, P = 0.02), left ventricular hypertrophy (17% vs 8%, P = 0.005), dyspnea during AFL (P < 0.001), mitral regurgitation (P = 0.002), tricuspid regurgitation (P = 0.049), and pulmonary hypertension (P = 0.01). Palpitations during AFL were less frequent in patients with persistent AFL (P = 0.001). Multivariate analysis revealed that age, weight, AFL diagnosis after initiation of class IC or III antiarrhythmic drugs for atrial fibrillation, history of left ventricular hypertrophy, dyspnea during AFL and mitral regurgitation on echocardiography were significant independent variables associated with persistent AFL. A history of atrial fibrillation and palpitations during AFL were independently associated with paroxysmal AFL. CONCLUSIONS: We were able to identify clinical and echocardiographic risk factors associated with persistence of typical AFL. Treatment of these risk factors can potentially not only prevent the transition from paroxysmal to persistent AFL, but maybe also the development or initiation of AFL in general.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Flutter Atrial/diagnóstico , Flutter Atrial/epidemiologia , Ecocardiografia/estatística & dados numéricos , Idoso , Fibrilação Atrial/prevenção & controle , Flutter Atrial/prevenção & controle , Doença Crônica , Comorbidade , República Tcheca/epidemiologia , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade
5.
J Cardiovasc Electrophysiol ; 23(7): 717-21, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22429859

RESUMO

INTRODUCTION: In order to optimize power delivery into the myocardium during radiofrequency ablation (RFA) without overheating the electrode tip, active cooling of the tip electrode as well as electrode tips made of gold have evolved. Recently, an externally irrigated gold tip electrode ablation catheter has been developed to combine the advantages of these 2 technologies. We sought to investigate the procedural parameters tip temperature, delivered power and cooling flow requirements of the irrigated gold tip catheter in comparison to the conventional irrigated platinum iridium (Pt) tip catheter in pulmonary vein isolation (PVI) and cavotricuspid isthmus (CTI) ablation. METHODS AND RESULTS: Sixty patients referred for first PVI were randomized into ablation with irrigated gold tip catheter versus irrigated Pt tip catheter. Forty-nine patients received ablation of CTI following PVI. Mean and standard deviation from all measurements were calculated for each patient. During RFA of pulmonary veins, mean catheter tip temperature was significantly lower in the gold group (35.4 ± 0.9 °C vs 38.2 ± 0.8 °C, P < 0.001), and total amount of delivered energy was higher (1303.1 ± 81.1 W vs 1223.7 ± 115.6 W, P = 0.004). During CTI ablation, necessary saline flow was almost 2.5-fold lower in the gold group (22.5 ± 5.9 mL/min vs 52.5 ± 9.7 mL/min, P < 0.001), accompanied by significantly lower tip temperature (39.1 ± 0.6 °C vs 40.5 ± 1.4 °C, P < 0.001). CONCLUSION: The irrigated gold tip electrode allows to deliver significantly more energy at a lower electrode tip temperature in RFA of PV and CTI in comparison to the irrigated Pt tip electrode. The required saline flow during CTI ablation is much lower than in Pt.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Catéteres , Ouro , Temperatura Alta , Platina , Veias Pulmonares/cirurgia , Irrigação Terapêutica/instrumentação , Valva Tricúspide/cirurgia , Veia Cava Inferior/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Resultado do Tratamento , Valva Tricúspide/fisiopatologia , Veia Cava Inferior/fisiopatologia
6.
J Cardiovasc Electrophysiol ; 23(3): 247-55, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21955059

RESUMO

OBJECTIVE: Since predictors of recurrence of atrial fibrillation (AF) after ablation procedures are poorly defined, this prospective study was conducted to assess the value of left atrial (LA) deformation imaging with two-dimensional speckle-tracking (2D-ST) to predict AF recurrences after successful ablation procedures. METHODS AND RESULTS: One hundred and three consecutive patients (age 58.1 ± 16.6 years, 72.8% male) with AF (76 paroxysmal, 27 persistent) and 30 matched controls underwent transthoracic echocardiography and 2D-ST-LA-deformation analysis with assessment of LA-radial and LA-longitudinal strain (Sr, Sl), and velocities derived from the apical 4- and 2-chamber views (4CV, 2CV). AF recurrence was assessed during 6 months of follow-up. For determination of AF-related LA changes, AF patients were compared to controls and patients with AF recurrences after ablation procedures (n = 30, 29.1%) were compared with patients who maintained sinus rhythm (n = 73, 70.9%). Atrial deformation capabilities were significantly reduced (P < 0.0005) in patients with AF (4CVSl 17.8 ± 13.5%; 4CVSr 22.3 ± 14.9%; 4CV-velocities 2.53 ± 0.97 seconds) when compared with controls (4CVSl 31.3 ± 12.4%; 4CVSr 30.3 ± 9.1%; 4CV-velocities 3.48 ± 1.01 cm/s). Independent predictors for AF recurrence after ablation procedures were 2CV-LA-global-strain (Sr, P = 0.03; Sl, P = 0.003), 4CV-LA-gobal-strain (Sr, P = 0.03; Sl, P = 0.02), and regional LA-septal wall-Sl (P = 0.008). LA-global-strain parameters were superior to regional LA function analysis for the prediction of AF recurrences, with cutoff values (cov), hazard ratios (HR), positive and negative predictive values (PPV, NPV) were: 4CVSl cov, 10.79% (HR 27.8, P < 0.0005; PPV 78.8%, NPV 93.9%), 4CVSr cov, -16.65% (HR 24.8, P < 0.0005; PPV 69.4%, NPV 96.6%), 2CVSl cov, 12.31% (HR 22.7, P < 0.0005; PPV 75.8%, NPV 95.3%), and 2CVSr cov, -14.9% (HR 12.9, P < 0.0005; PPV 64.3%, NPV 93.2%). CONCLUSION: Compared with controls, AF itself seems to decrease LA deformation capabilities. The assessment of global LA strain with 2D-ST identifies patients with high risk for AF recurrence after ablation procedures. This imaging technique may help to improve therapeutic guiding for patients with AF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Idoso , Função do Átrio Esquerdo , Estudos de Coortes , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Recidiva , Reprodutibilidade dos Testes
7.
Europace ; 13(1): 102-8, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20876601

RESUMO

AIMS: Gold electrodes have the theoretical advantage of creating bigger lesions than platinum-iridium (Pt-Ir) electrodes. We performed a prospective randomized study to compare the clinical efficacy of standard 8 mm Pt-Ir tip catheter (control) and 8 mm gold-tip catheters in the ablation of the cavotricuspid isthmus (CTI)-dependent atrial flutter. METHODS AND RESULTS: A total of 463 patients undergoing CTI ablation in 19 clinical centres were randomized to receive the treatment by gold-tip or control catheter. The primary endpoint was cumulative radiofrequency (RF) application duration until achieving bidirectional CTI block. It did not differ significantly for the two catheters. The gold-tip catheter was, however, associated with a higher ablation success rate (94.3 vs. 89.0%, P = 0.042) and a substantially lower incidence of char and coagulum formation (4.8 vs. 37.9%, P < 0.001), which required exchange of 1 gold-tip (0.4%) and 10 control catheters (4.6%, P = 0.005). The gold-tip catheter delivered more mean power (52 ± 12 W) than the control catheter (48 ± 13 W, P < 0.001). Both mean and maximum temperatures measured by the thermocouple integrated in the catheter tip were statistically significantly lower in the gold (mean: 53.2 ± 4.7°C, max: 68.7 ± 6.6°C) than in the control catheter (54.3 ± 5.2 and 70.2 ± 7.0°C, respectively, P < 0.05). Fluoroscopy time, procedure duration, procedural-related complications, and arrhythmia recurrence during 6 months of follow-up did not differ between the two catheters. CONCLUSION: Owing to a higher primary ablation success rate and reduced incidence of char/coagulum formation, gold may be preferred over Pt-Ir as electrode material for 8 mm tip catheters for CTI ablation. ClinicalTrials.gov: NCT00326001 (http://clinicaltrials.gov/ct2/show/NCT00326001).


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/instrumentação , Ouro , Irídio , Platina , Idoso , Ablação por Cateter/métodos , Eletrodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Estudos Retrospectivos , Condutividade Térmica , Resultado do Tratamento
8.
J Interv Card Electrophysiol ; 29(1): 37-41, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20714922

RESUMO

OBJECTIVES: To address the question whether obstructive sleep apnea (OSA) is associated with the recurrence of paroxysmal atrial fibrillation (AF) in patients treated with ≥2 pulmonary vein isolation procedures. PATIENTS AND METHODS: In this study, we included adults with therapy-resistant symptomatic paroxysmal AF, defined as AF recurring after ≥2 PV-isolation procedures (n = 23). For comparison, we selected another cohort of patients being successfully treated by one PV isolation without AF recurrence within 6 months (n = 23). PV isolation was performed by radiofrequency with an open irrigated tip catheter. Each of the 46 participants completed an overnight polygraphic study. The two groups were matched for age, gender, and ejection fraction. Patients were late middle-aged (65 ± 7 vs 63 ± 10 years, P = 0.23), white (100%), and overweight (BMI 27.3 ± 3.6 vs. 27.2 ± 4.6 kg/m(2), P = 0.97). RESULTS: The prevalence of sleep apnea, defined as an apnea-hypopnea index (AHI) of >5 per hour of sleep, was 87% in patients with therapy-resistant AF compared to 48% in the control cohort (P = 0.005). In addition, OSA was more severe in the resistant AF group indicated by a significantly higher AHI (27 ± 22 vs 12 ± 16, P = 0.01). CONCLUSION: The extraordinarily high prevalence of sleep apnea in patients with recurrent paroxysmal AF supports its presumable role in the pathogenesis of AF and demands further controlled prospective trials. Moreover, OSA should inherently be considered in patients with therapy-resistant AF.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Apneia Obstrutiva do Sono/epidemiologia , Distribuição por Idade , Idoso , Fibrilação Atrial/diagnóstico , Índice de Massa Corporal , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Prevalência , Recidiva , Valores de Referência , Índice de Gravidade de Doença , Distribuição por Sexo , Apneia Obstrutiva do Sono/diagnóstico , Taquicardia Paroxística/diagnóstico , Taquicardia Paroxística/epidemiologia , Taquicardia Paroxística/cirurgia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 20(12): 1343-8, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19656254

RESUMO

INTRODUCTION: Ablation of pulmonary veins (PV) is an established therapeutic option for patients with symptomatic drug-refractory paroxysmal atrial fibrillation (AF). Radiofrequency (RF) is currently the most widespread energy source for PV ablation. Cryothermal energy applied with a cryoballoon technique as an alternative has recently evolved. METHODS AND RESULTS: In a case-control setting, we compared 20 patients with paroxysmal AF who underwent their first PV ablation with the cryoballoon technique to 20 matched patients with conventional RF ablation. In the case of persistent electrical potentials after cryoballoon ablation, it was combined with ablation with a conventional cryocatheter. All patients performed daily event recording for 3 months after ablation procedure. Ablation parameters and success rate after 3 and 6 months were compared. In the cryoballoon group, the overall success rate was 55% (50% in the cryoballoon only group [14 patients] and 66% in the combination group [6 patients]), as opposed to the RF group with 45%. AF episode burden was lower after cryoballoon ablation. There was no significant difference between cryoballoon and RF ablation regarding procedure parameters. In the cryoballoon group, 3 phrenic nerve palsies occurred using the 23 mm balloon that resolved spontaneously. CONCLUSION: PV ablation with the cryoballoon technique is feasible and seems to have a similar success rate in comparison to RF ablation. Procedure- and fluoroscopy duration are not longer than in conventional RF ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Cateterismo/métodos , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...