Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Med (Lausanne) ; 9: 1028645, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36405623

RESUMO

Purpose: To investigate ciliochoroidal detachment (CCD) frequency and risk factors after performing microhook ab interno trabeculotomy (µLOT). Methods: A retrospective evaluation of 62 eyes of 62 patients who underwent µLOT and were subsequently examined by anterior-segment optical coherence tomography (AS-OCT) found CCD at 1 day, and 1 and 2 months after surgery. Results: In the 62 patients (mean age 67.3 ± 13.9 years), AS-OCT detected CCD in 18 eyes (29%) at 1 day after surgery, which disappeared within 1 month. Comparisons between the CCD vs. the non-CCD group showed the mean IOPs were 11.7 ± 1.5 mmHg vs. 14.4 ± 1.0 mmHg at day 1 (P = 0.13), 12.2 ± 1.1 mmHg vs. 14.8 ± 0.7 mmHg at day 7 (P = 0.06), 12.2 ± 0.7 mmHg vs. 12.9 ± 0.5 mmHg at 1 month (P = 0.48), and 11.3 ± 0.7 mmHg vs. 12.7 ± 0.5 mmHg at 2 months (P = 0.09). For postoperative IOP, there were no significant differences observed. After undergoing µLOT, multiple regression analysis demonstrated that the CCD development might be influenced by the presence of a thinner central corneal thickness. Conclusion: Approximately one-third of all patients exhibited CCD after µLOT. A thinner central corneal thickness was found to be a risk factor for developing CCD.

2.
Cureus ; 14(6): e26445, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35915674

RESUMO

In recent years, glaucoma tube surgery has been recommended for refractory cases that have failed to respond to angle surgery. In this study, we described the case of the fibrous proliferative membrane caused in the anterior chamber after Ahmed glaucoma valve implantation in a pediatric glaucoma patient. He was born full term, weighing 3228 g. Corneal opacity in both eyes was seen at birth and he was referred to the Department of Ophthalmology, Hiroshima University Hospital on the 13th day of his life. At the initial examination, the intraocular pressure was 37mmHg right 25mmHg left. Corneal diameter expansion and diffuse corneal opacity were seen in both eyes. Nine days after the initial examination, trabeculotomy was performed in both eyes but they were ineffective, and Ahmed glaucoma tubes were inserted in both eyes two months later. Four months later the intraocular pressure remained 30mmHg range in both eyes and micropulse cyclophotocoagulation was performed. One year after the Ahmed glaucoma valve implantation, the tube of right eye was exposed, and we planned to perform a repair procedure. At this time, ultrasound biomicroscopy (UBM) showed proliferative tissue around both tubes. They were removed next month. Although silicone is a highly biocompatible material, it can cause foreign body reactions such as encapsulation around the silicone plate and proliferative membranes around silicone oil. We speculated that a similar reaction occurred to the silicone tube in this case. We reported a case of fibrous proliferative membrane in the anterior chamber. This might be caused by the silicon tube of the Ahmed glaucoma valve.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...