Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Bio Mater ; 4(4): 3055-3066, 2021 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35014394

RESUMO

Implant placement is an important repair method in dentistry and orthopedics. Increasing efforts have focused on optimizing the biocompatibility and osseointegration properties of titanium (Ti) and Ti-based alloys. In this work, Ti-based alloys were modified by the layer-by-layer (LbL) technique, which is a simple and versatile method for surface modification. The morphology and chemical structure of LbL films of poly(sodium 4-styrenesulfonate) (PSS) and Ti dioxide (TiO2) nanoparticles were first characterized employing ultraviolet-visible and Fourier-transform infrared spectroscopies as well as atomic force microscopy for further application in Ti-based alloy implants. The changes provoked by the LbL PSS/TiO2 film on the Ti-based alloy surfaces were then investigated by scanning electron microscopy and micro-Raman techniques. Finally, in vivo tests (immunolabeling and biomechanical analysis) performed with screw implants in rats suggested that PSS/TiO2 multilayers promote changes in both topography and chemical surface properties of the screw, providing beneficial effects for osteoblast activity. This simple and relatively low-cost growth process can open up possibilities to improve dental implants and, probably, bone implants in general.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Implantes Dentários , Poliestirenos/química , Titânio/química , Materiais Biocompatíveis/síntese química , Teste de Materiais , Tamanho da Partícula
2.
Mater Sci Eng C Mater Biol Appl ; 102: 315-323, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31147004

RESUMO

The conjugation of nanoparticles with antibodies has been successfully applied in sandwich immunoassays for detecting cancer biomarkers. However, two antibodies are necessary to perform such experiment, being one of them functionalized with a signal label for optical or electrochemical assay. This approach is time and cost consuming compared to direct label-free immunoassays. In this study, we propose the synthesis of gold nanoparticles conjugated to anti-PSA antibody to produce a label-free impedimetric immunosensors based on nanostructured Layer-by-Layer (LbL) films. Prostate-specific antigen (PSA) detection was performed by electrochemical impedance spectroscopy demonstrating a detection mechanism governed by Langmuir-Freundlich adsorption model. This strategy provided a significant sensitivity using 10-fold less antibody than conventional immunosensors, i.e. decreasing costs using a simple approach, with a limit of detection of 0.17 ng mL-1 and an analytical range of 0.1-20 ng mL-1 indicating that our sensor is potentially useful for clinical applications.


Assuntos
Anticorpos/metabolismo , Ouro/química , Imunoensaio/métodos , Nanopartículas Metálicas/química , Coloração e Rotulagem , Técnicas Biossensoriais , Nanopartículas Metálicas/ultraestrutura , Antígeno Prostático Específico/metabolismo , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta
3.
J Nanosci Nanotechnol ; 19(9): 5483-5488, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30961700

RESUMO

Distinct architectures of layer-by-layer (LbL) films made of carbon nanotubes and gold nanoparticles were investigated to serve as the matrix to immobilize cholesterol oxidase, with which cholesterol could be detected using amperometry. The gold nanoparticles were synthesized by metal reduction stabilized in poly(allylamine hydrochloride) (PAH) providing a stable AuNPs-PAH suspension, while multi-walled carbon nanotubes (CNTs) were functionalized with carboxylic groups to obtain an aqueous suspension. The LbL films were deposited on ITO, with a cushion film of PAH and poly(vinyl sulfonic acid) (PVS). Owing to the synergy between CNTs and AuNPs, the electrode ITO/(PAH/PVS)2 (AuNPs-PAH/CNTs)10 was selected for immobilization of cholesterol oxidase (ChOx). This sensor could detect cholesterol with a limit of detection of 14.8 µmol L-1 and sensitivity of 36.47 (µA cm-2)·(mmol L-1)-1. It was also able to determine cholesterol in egg yolk with a recovery of 97.7%.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Nanotubos de Carbono , Colesterol , Ouro
4.
Biosens Bioelectron ; 119: 86-93, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30103158

RESUMO

As a direct, label-free method, Surface Plasmon Resonance (SPR) detection significantly reduces the needs for liquid handling and reagent storage compared to common enzyme-linked immunosorbent assays (ELISAs), thus enabling comprehensive multiplexing of bioassays on microfluidic sample-to-answer systems. This paper describes a highly integrated centrifugal Lab-on-a-Disc (LoaD) platform for automating the full process chain extending between plasma extraction and subsequent aliquoting to five parallelized reaction channels for quantitative SPR detection by an inexpensive smartphone camera. The entire, multi-step / multi-reagent operation completes within less than 1 h. While the emphasis of this work is on the fluidic automation and parallelization by previously introduced, very robust event-triggered valving and buoyancy-driven centripetal pumping schemes, we successfully implement an immunoglobulin G (IgG) assay; by specific functionalization of the detection surfaces, the same disc layout can readily be customised for immunoassays panels from whole blood.


Assuntos
Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Imunoensaio/instrumentação , Imunoensaio/métodos , Imunoglobulina G/biossíntese , Técnicas Analíticas Microfluídicas , Ressonância de Plasmônio de Superfície , Técnicas Biossensoriais , Humanos
5.
Biosens Bioelectron ; 109: 214-223, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29567566

RESUMO

In this paper we present a wirelessly powered array of 128 centrifugo-pneumatic valves that can be thermally actuated on demand during spinning. The valves can either be triggered by a predefined protocol, wireless signal transmission via Bluetooth, or in response to a sensor monitoring a parameter like the temperature, or homogeneity of the dispersion. Upon activation of a resistive heater, a low-melting membrane (Parafilm™) is removed to vent an entrapped gas pocket, thus letting the incoming liquid wet an intermediate dissolvable film and thereby open the valve. The proposed system allows up to 12 heaters to be activated in parallel, with a response time below 3 s, potentially resulting in 128 actuated valves in under 30 s. We demonstrate, with three examples of common and standard procedures, how the proposed technology could become a powerful tool for implementing diagnostic assays on Lab-on-a-Disc. First, we implement wireless actuation of 64 valves during rotation in a freely programmable sequence, or upon user input in real time. Then, we show a closed-loop centrifugal flow control sequence for which the state of mixing of reagents, evaluated from stroboscopically recorded images, triggers the opening of the valves. In our last experiment, valving and closed-loop control are used to facilitate centrifugal processing of whole blood.


Assuntos
Técnicas Biossensoriais , Técnicas Analíticas Microfluídicas/métodos , Tecnologia sem Fio , Centrifugação , Membranas Artificiais , Pressão , Rotação
6.
Colloids Surf B Biointerfaces ; 158: 167-174, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28689099

RESUMO

Antibody immobilization on polymeric substrates is a key manufacturing step for microfluidic devices that implement sample-to-answer automation of immunoassays. In this work, a simple and versatile method to bio-functionalize poly(methylmethacrylate) (PMMA), a common material of such "Lab-on-a-Chip" systems, is proposed; using the Layer-by-Layer (LbL) technique, we assemble nanostructured thin films of poly(ethylene imine) (PEI) and graphene oxide (GO). The wettability of PMMA surfaces was significantly augmented by the surface treatment with (PEI/GO)5 film, with an 81% reduction of the contact angle, while the surface roughness increased by 600%, thus clearly enhancing wettability and antibody binding capacity. When applied to enzyme-linked immunosorbent assays (ELISAs), the limit of detection of PMMA surface was notably improved from 340pgmL-1 on commercial grade polystyrene (PS) and 230pgmL-1 on plain PMMA surfaces to 130pgmL-1 on (PEI/GO)5 treated PMMA. Furthermore, the accelerated antibody adsorption kinetics on the LbL films of GO allowed to substantially shorten incubation times, e.g. for anti-rat IgG adsorption from 2h down to 15min on conventional and treated surfaces, respectively.


Assuntos
Grafite/química , Polietilenoimina/química , Ensaio de Imunoadsorção Enzimática , Imunoensaio/métodos , Cinética , Polimetil Metacrilato/química
7.
Int J Mol Sci ; 14(7): 12953-69, 2013 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-23797657

RESUMO

We report on optimized architectures containing layer-by-layer (LbL) films of natural rubber latex (NRL), carboxymethyl-chitosan (CMC) and magnetite (Fe3O4) nanoparticles (MNPs) deposited on flexible substrates, which could be easily bent by an external magnetic field. The mechanical response depended on the number of deposited layers and was explained semi-quantitatively with a fully atomistic model, where the LbL film was represented as superposing layers of hexagonal graphene-like atomic arrangements deposited on a stiffer substrate. The bending with no direct current or voltage being applied to a supramolecular structure containing biocompatible and antimicrobial materials represents a proof-of-principle experiment that is promising for tissue engineering applications in biomedicine.


Assuntos
Campos Magnéticos , Nanopartículas , Materiais Biocompatíveis/química , Nanopartículas/química
8.
Analyst ; 135(10): 2481-95, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20730141

RESUMO

This minireview describes the main developments of electronic tongues (e-tongues) and taste sensors in recent years, with a summary of the principles of detection and materials used in the sensing units. E-tongues are sensor arrays capable of distinguishing very similar liquids employing the concept of global selectivity, where the difference in the electrical response of different materials serves as a fingerprint for the analysed sample. They have been widely used for the analysis of wines, fruit juices, coffee, milk and beverages, in addition to the detection of trace amounts of impurities or pollutants in waters. Among the various principles of detection, electrochemical measurements and impedance spectroscopy are the most prominent. With regard to the materials for the sensing units, in most cases use is made of ultrathin films produced in a layer-by-layer fashion to yield higher sensitivity with the advantage of control of the film molecular architecture. The concept of e-tongues has been extended to biosensing by using sensing units capable of molecular recognition, as in films with immobilized antigens or enzymes with specific recognition for clinical diagnosis. Because the identification of samples is basically a classification task, there has been a trend to use artificial intelligence and information visualization methods to enhance the performance of e-tongues.


Assuntos
Técnicas Biossensoriais/métodos , Eletrônica , Espectroscopia Dielétrica , Técnicas Eletroquímicas/métodos , Miniaturização , Análise de Componente Principal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...