Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Chem Commun (Camb) ; 60(50): 6447-6450, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38832782

RESUMO

The ability of NaCl-type binary transition metal nitrides (incorporating La, Ce, Y, Zr or Hf) to act as catalytic supports facilitating ammonia decomposition was examined. The effect of nitrogen vacancies formed on nitrides can be understood in terms of the ionic radii of the metal cations. A clear correlation between the N2 desorption temperature and catalytic activity was found.

2.
J Appl Clin Med Phys ; : e14408, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38863310

RESUMO

PURPOSE: The study aimed to investigate the optimal isodose line (IDL) in linear accelerator-based stereotactic radiotherapy for single brain metastasis, using HyperArc. We compared the dosimetric parameters for target and normal brain tissue among six plans with different IDLs. METHODS: This study included 30 patients with single brain metastasis. We retrospectively generated six plans for each tumor with different IDLs (80%, 70%, 60%, 50%, 40%, and 33%) using HyperArc. All treatment plans were normalized to the prescription dose of 35 Gy in five fractions which was covered by 95% of the planning target volume (PTV), defined by adding a 1.0 mm margin to the gross tumor volume (GTV). The dosimetric parameters were compared among the six plans. RESULTS: For GTV > 0.1 cm3, the ratio of brain-GTV volumes receiving 25 Gy to PTV (V25Gy/PTV) was significantly lower at IDL 40%-70% than at IDL 80% and 33% (p < 0.01, retrospectively). For GTV < 0.1 cm3, V25Gy/PTV decreased continuously as IDL decreased. The values of D99% and D80% for GTV increased with decreasing IDL. An IDL of 50% or less was required to achieve D99% of greater than 43 Gy and D80% of greater than 50 Gy. The mean values of D99% and D80% for IDL 50% were 44.3 and 51.9 Gy. CONCLUSION: The optimal IDL is 40%-50% for GTV > 0.1 cm3. These lower IDLs could increase D99% and D80% of GTV while lowering V25Gy of normal brain tissue, which may help reduce the risk of radiation necrosis and improve local control.

3.
J Imaging Inform Med ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637424

RESUMO

While dual-energy computed tomography (DECT) technology introduces energy-specific information in clinical practice, single-energy CT (SECT) is predominantly used, limiting the number of people who can benefit from DECT. This study proposed a novel method to generate synthetic low-energy virtual monochromatic images at 50 keV (sVMI50keV) from SECT images using a transformer-based deep learning model, SwinUNETR. Data were obtained from 85 patients who underwent head and neck radiotherapy. Among these, the model was built using data from 70 patients for whom only DECT images were available. The remaining 15 patients, for whom both DECT and SECT images were available, were used to predict from the actual SECT images. We used the SwinUNETR model to generate sVMI50keV. The image quality was evaluated, and the results were compared with those of the convolutional neural network-based model, Unet. The mean absolute errors from the true VMI50keV were 36.5 ± 4.9 and 33.0 ± 4.4 Hounsfield units for Unet and SwinUNETR, respectively. SwinUNETR yielded smaller errors in tissue attenuation values compared with those of Unet. The contrast changes in sVMI50keV generated by SwinUNETR from SECT were closer to those of DECT-derived VMI50keV than the contrast changes in Unet-generated sVMI50keV. This study demonstrated the potential of transformer-based models for generating synthetic low-energy VMIs from SECT images, thereby improving the image quality of head and neck cancer imaging. It provides a practical and feasible solution to obtain low-energy VMIs from SECT data that can benefit a large number of facilities and patients without access to DECT technology.

4.
Br J Radiol ; 97(1158): 1162-1168, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38648776

RESUMO

OBJECTIVES: A portable respiratory training system with a gyroscope sensor (gyroscope respiratory training system [GRTS]) was developed and the feasibility of respiratory training was evaluated. METHODS: Simulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing expiratory breath-hold radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively. RESULTS: The absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.0%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 96.1% for free breathing and 88.2% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm and 91.0% (6.9) and 89.1% (11.6), respectively. CONCLUSIONS: Respiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold radiation therapy. ADVANCES IN KNOWLEDGE: A respiratory training system with a gyroscope sensor is inexpensive and portable, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.


Assuntos
Estudos de Viabilidade , Humanos , Reprodutibilidade dos Testes , Masculino , Adulto , Imagens de Fantasmas , Feminino , Suspensão da Respiração , Exercícios Respiratórios/instrumentação , Exercícios Respiratórios/métodos , Pessoa de Meia-Idade , Respiração , Desenho de Equipamento
5.
Phys Eng Sci Med ; 47(2): 597-609, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38353926

RESUMO

In linear accelerator-based stereotactic irradiation (STI) for brain metastasis, cone-beam computed tomography (CBCT) image quality is essential for ensuring precise patient setup and tumor localization. However, CBCT images may be degraded by the deviation of the CBCT isocenter from the brain center. This study aims to investigate the effects of the distance from the brain center to the CBCT isocenter (DBI) on the image quality in STI. An anthropomorphic phantom was scanned with varying DBI in right, anterior, superior, and inferior directions. Thirty patients undergoing STI were prospectively recruited. Objective metrics, utilizing regions of interest included contrast-to-noise ratio (CNR) at the centrum semiovale, lateral ventricle, and basal ganglia levels, gray and white matter noise at the basal ganglia level, artifact index (AI), and nonuniformity (NU). Two radiation oncologists assessed subjective metrics. In this phantom study, objective measures indicated a degradation in image quality for non-zero DBI. In this patient study, there were significant correlations between the CNR at the centrum semiovale and lateral ventricle levels (rs = - 0.79 and - 0.77, respectively), gray matter noise (rs = 0.52), AI (rs = 0.72), and NU (rs = 0.91) and DBI. However, no significant correlations were observed between the CNR at the basal ganglia level, white matter noise, and subjective metrics and DBI (rs < ± 0.3). Our results demonstrate the effects of DBI on contrast, noise, artifacts in the posterior fossa, and uniformity of CBCT images in STI. Aligning the CBCT isocenter with the brain center can aid in improving image quality.


Assuntos
Encéfalo , Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Radiocirurgia , Humanos , Encéfalo/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Idoso , Razão Sinal-Ruído , Processamento de Imagem Assistida por Computador , Adulto , Artefatos
6.
Int J Comput Assist Radiol Surg ; 19(3): 541-551, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38219257

RESUMO

PURPOSE: While dual-energy computed tomography (DECT) images provide clinically useful information than single-energy CT (SECT), SECT remains the most widely used CT system globally, and only a few institutions can use DECT. This study aimed to establish an artificial intelligence (AI)-based image-domain material decomposition technique using multiple keV-output learning of virtual monochromatic images (VMIs) to create DECT-equivalent images from SECT images. METHODS: This study involved 82 patients with head and neck cancer. Of these, the AI model was built with data from the 67 patients with only DECT scans, while 15 patients with both SECT and DECT scans were used for SECT testing. Our AI model generated VMI50keV and VMI100keV from VMI70keV equivalent to 120-kVp SECT images. We introduced a loss function for material density images (MDIs) in addition to the loss for VMIs. For comparison, we trained the same model with the loss for VMIs only. DECT-equivalent images were generated from SECT images and compared with the true DECT images. RESULTS: The prediction time was 5.4 s per patient. The proposed method with the MDI loss function quantitatively provided more accurate DECT-equivalent images than the model trained with the loss for VMIs only. Using real 120-kVp SECT images, the trained model produced precise DECT images of excellent quality. CONCLUSION: In this study, we developed an AI-based material decomposition approach for head and neck cancer patients by introducing the loss function for MDIs via multiple keV-output learning. Our results suggest the feasibility of AI-based image-domain material decomposition in a conventional SECT system without a DECT scanner.


Assuntos
Inteligência Artificial , Neoplasias de Cabeça e Pescoço , Humanos , Tomografia Computadorizada por Raios X/métodos , Cintilografia , Doses de Radiação , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem
7.
Strahlenther Onkol ; 200(1): 39-48, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37591978

RESUMO

PURPOSE: The geometric distortion related to magnetic resonance (MR) imaging in a diagnostic radiology (MRDR) and radiotherapy (MRRT) setup is evaluated, and the dosimetric impact of MR distortion on fractionated stereotactic radiotherapy (FSRT) in patients with brain metastases is simulated. MATERIALS AND METHODS: An anthropomorphic skull phantom was scanned using a 1.5­T MR scanner, and the magnitude of MR distortion was calculated with (MRDR-DC and MRRT-DC) and without (MRDR-nDC and MRRT-nDC) distortion-correction algorithms. Automated noncoplanar volumetric modulated arc therapy (HyperArc, HA; Varian Medical Systems, Palo Alto, CA, USA) plans were generated for 53 patients with 186 brain metastases. The MR distortion at each gross tumor volume (GTV) was calculated using the distance between the center of the GTV and the MR image isocenter (MIC) and the quadratic regression curve derived from the phantom study (MRRT-DC and MRRT-nDC). Subsequently, the radiation isocenter of the HA plans was shifted according to the MR distortion at each GTV (HADC and HAnDC). RESULTS: The median MR distortions were approximately 0.1 mm when the distance from the MIC was < 30 mm, whereas the median distortion varied widely when the distance was > 60 mm (0.23, 0.47, 0.37, and 0.57 mm in MRDR-DC, MRDR-nDC, MRRT-DC, and MRRT-nDC, respectively). The dose to the 98% of the GTV volume (D98%) decreased as the distance from the MIC increased. In the HADC plans, the relative dose difference of D98% was less than 5% when the GTV was located within 70 mm from the MIC, whereas the underdose of GTV exceeded 5% when it was 48 mm (-26.5% at maximum) away from the MIC in the HAnDC plans. CONCLUSION: Use of a distortion-correction algorithm in the studied MR diagnoses is essential, and the dosimetric impact of MR distortion is not negligible, particularly for tumors located far away from the MIC.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiocirurgia/métodos , Algoritmos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Imageamento por Ressonância Magnética/métodos , Dosagem Radioterapêutica
8.
J Am Chem Soc ; 145(48): 25976-25982, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-37983189

RESUMO

The base strength of oxide catalysts is controlled by the electron charge distribution between cations and anions, with unsaturated oxygen ions that have lone pair electrons typically acting as basic sites. Substitution of oxide ions with anions that have different valences, such as nitride and hydride ions, can often generate basic sites. It is plausible that electrons trapped at oxygen vacancy sites could provide increased electron density and shift the highest occupied molecular orbital energy levels of anions upward in the case that the oxygen vacancies couple with surface-substituted anions. The present work demonstrates that high catalytic basicity can be obtained via site-selective doping of anions at face-sharing Ti2O9 dimer sites with oxygen vacancies in BaTiO3-x. This improved basicity stems from the coupling of substituted nitride ions to electrons at oxygen vacancies. The oxynitride BaTiO3-xNy was found to contain nitride ions that have increased electronic charge density on the basis of such interactions. Enhanced surface basicity following doping with nitride ion was also confirmed by CO2 temperature-programmed desorption and infrared spectroscopy in conjunction with the adsorption of CHCl3. The strong Lewis base sites resulting from the formation of the oxynitride evidently facilitated the catalytic activation of C-H bonds to promote Knoevenagel condensation reactions between aldehydes and active methylene compounds with pKa values of up to 28.9.

9.
ChemSusChem ; 16(22): e202301576, 2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-37967287

RESUMO

Invited for this Issue's cover is the group of Professor Hideo Hosono at Tokyo Institute of Technology. The Cover image explores the question which activation dominates N2 activation for ammonia synthesis. The Research Article itself is available at 10.1002/cssc.202300551.

10.
J Am Chem Soc ; 2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37800540

RESUMO

N2 activation is a key step in the industrial synthesis of ammonia and other high-value-added N-containing chemicals, and typically is heavily reliant on transition metal (TM) sites as active centers to reduce the large activation energy barrier for N2 dissociation. In the present work, we report that a 2D electride of Ba2N with anionic electrons in the interlayer spacings works efficiently for TM-free N2 dissociation under mild conditions. The interlayer electrons significantly boost N2 dissociation with a very small activation energy of 35 kJ mol-1, as confirmed by the N2 isotopic exchange reaction. The reaction of anionic electrons with N2 molecules stabilizes (N2)2- anions, the so-called diazenide, in the large interlayer space (∼4.5 Å) sandwiched by 2 cationic slabs of Ba2N as the main intermediate.

11.
J Radiat Res ; 64(6): 940-947, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37839063

RESUMO

To explore predictors of the histopathological response to preoperative chemoradiotherapy (CRT) in patients with pancreatic cancer (PC) using dual-energy computed tomography-reconstructed images. This retrospective study divided 40 patients who had undergone preoperative CRT (50-60 Gy in 25 fractions) followed by surgical resection into two groups: the response group (Grades II, III and IV, evaluated from surgical specimens) and the nonresponse group (Grades Ia and Ib). The computed tomography number [in Hounsfield units (HUs)] and iodine concentration (IC) were measured at the locations of the aorta, PC and pancreatic parenchyma (PP) in the contrast-enhanced 4D dual-energy computed tomography images. Logistic regression analysis was performed to identify predictors of histopathological response. Univariate analysis did not reveal a significant relation between any parameter and patient characteristics or dosimetric parameters of the treatment plan. The HU and IC values in PP and the differences in HU and IC between the PP and PC (ΔHU and ΔIC, respectively) were significant predictors for distinguishing the response (n = 24) and nonresponse (n = 16) groups (P < 0.05). The IC in PP and ΔIC had a higher area under curve values [0.797 (95% confidence interval, 0.659-0.935) and 0.789 (0.650-0.928), respectively] than HU in PP and ΔHU [0.734 (0.580-0.889) and 0.721 (0.562-0.881), respectively]. The IC value could potentially be used for predicting the histopathological response in patients who have undergone preoperative CRT.


Assuntos
Iodo , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Meios de Contraste , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Quimiorradioterapia/métodos , Neoplasias Pancreáticas
12.
Sci Adv ; 9(38): eadh9104, 2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37738353

RESUMO

Topological materials have received much attention because of their robust topological surface states, which can be potentially applied in electronics and catalysis. Here, we show that the topological insulator bismuth selenide functions as an efficient catalyst for the oxidative carbonylation of amines with carbon monoxide and dioxygen to synthesize urea derivatives. For example, the carbonylation of butylamine can be completed over bismuth selenide nanoparticle catalyst in 4 hours at 20°C with a yield of 99%, whereas most noble metal-based catalysts do not function at such a low temperature. Density functional theory calculations further reveal that the topological surface states facilitate the activation of dioxygen through a triplet-to-singlet spin-conversion reaction, in which active oxygen species are formed with a barrier of 0.4 electron volts for the subsequent reactions with amine and carbon monoxide.

13.
J Radiat Res ; 64(4): 644-650, 2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37280131

RESUMO

In volumetric modulated arc therapy (VMAT), the effect of an increase in skin surface dose due to topical agents might be negligible. We investigated the bolus effects of three types of topical agents in VMAT for head and neck cancer (HNC). Topical agents of different thicknesses (0.1, 0.5 and 2 mm) were prepared. When each topical agent was set, the surface doses were measured for the anterior static field and VMAT, with and without a thermoplastic mask. No significant differences were observed among the three topical agents. For topical agent thicknesses of 0.1, 0.5 and 2 mm, the increases in surface dose for the anterior static field without the thermoplastic mask were 7-9, 30-31 and 81-84%, respectively. With the thermoplastic mask, the corresponding increases were 5, 12-15 and 41-43%, respectively. The increases in surface dose for VMAT without the thermoplastic mask were 5-8, 16-19 and 36-39%, respectively, and those with the thermoplastic mask were 4, 7-10 and 15-19%, respectively. The rate of increase in surface dose with the thermoplastic mask was smaller than that without the thermoplastic mask. The increase in surface dose with topical agents of clinical standard thickness (0.02 mm) was estimated to be 2% with the thermoplastic mask. The increase in surface dose with topical agents in dosimetric simulation, compared with control situation, is not significant in clinical conditions for HNC patients.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Neoplasias de Cabeça e Pescoço/radioterapia , Radiometria
14.
Anticancer Res ; 43(7): 3079-3087, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37351970

RESUMO

BACKGROUND/AIM: Angiosarcoma of the scalp (AS) is a rare tumor that has often been treated by total scalp irradiation (TSI). TSI has technical and dosimetric challenges. This study aimed to compare the dosimetric performance of helical tomotherapy (HT) plans with that of HyperArc (HA) plans for TSI in AS. PATIENTS AND METHODS: A planning study was conducted for 11 patients with AS (70 Gy/35 fr). HT and HA planning was performed using TomoHDA and TrueBeam Edge systems, respectively. The performance of three different plans were compared: HT, HA, and HA with half-field beams (HF-HA). The dose distribution and dosimetric parameters for each plan were evaluated. RESULTS: All constraint parameters for the target and organs at risk (OARs) met the goals within acceptable limits for the three techniques. The HA and HF-HA plans provided significantly lower mean brain dose (12.46±2.48 Gy and 8.02±1.48 Gy) than did the HT plan (17.59±3.47 Gy). The doses receiving 0.1 cc of the volume for brainstem and chiasm were significantly lower in the HA and HF-HA plans than those in the HT plan. The HA and HF-HA plans provided a shorter beam-on time (155±3 s and 181±14 s) than did the HT plan (962±221 s). CONCLUSION: The HA plan provided significantly better OARs sparing than the HT plan for TSI in AS and had an advantage to using half-field beams.


Assuntos
Hemangiossarcoma , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Couro Cabeludo , Hemangiossarcoma/radioterapia , Órgãos em Risco/efeitos da radiação
15.
J Am Chem Soc ; 145(19): 10669-10680, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37129031

RESUMO

Electrides are promising support materials to promote transition metal catalysts for ammonia synthesis due to their strong electron-donating ability. Cobalt (Co) is an alternative non-noble metal catalyst to ruthenium in ammonia synthesis; however, it is difficult to achieve acceptable activity at low temperatures due to the weak Co-N interaction. Here, we report a novel oxyhydride electride, BaAl2O4-xHy, that can significantly promote ammonia synthesis over Co (500 mmol gCo-1 h-1 at 340 °C and 0.90 MPa) with a very low activation energy (49.6 kJ mol-1; 260-360 °C), which outperforms the state-of-the-art Co-based catalysts, being comparable to the latest Ru catalyst at 300 °C. BaAl2O4-xHy with a stuffed tridymite structure has interstitial cage sites where anionic electrons are accommodated. The surface of BaAl2O4-xHy with very low work functions (1.7-2.6 eV) can donate electrons strongly to Co, which largely facilitates N2 reduction into ammonia with the aid of the lattice H- ions. The stuffed tridymite structure of BaAl2O4-xHy with a three-dimensional AlO4-based tetrahedral framework has great chemical stability and protects the accommodated electrons and H- ions from oxidation, leading to robustness toward the ambient atmosphere and good reusability, which is a significant advantage over the reported hydride-based catalysts.

16.
ChemSusChem ; 16(22): e202300551, 2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-37243513

RESUMO

Nitride and hydride materials have been proposed as active supports for the loading of transition metal catalysts in thermal catalytic ammonia synthesis. However, the contribution of nitrogen or hydride anions in the support to the catalytic activity for supported transition-metal catalysts is not well understood, especially for Fe-based catalysts. Here, we report that hexagonal-BaTiO3-x Ny with nitrogen vacancies at face-sharing sites acts as a more efficient support for Fe catalysts for ammonia synthesis than BaTiO3 or BaTiO3-x Hx at 260 °C to 400 °C. Isotopic experiments, in situ measurements, and a small inverse isotopic effect in ammonia synthesis have revealed that nitrogen molecules are activated at nitrogen vacancies formed at the interface between Fe nanoparticles and the support. Nitrogen vacancies on BaTiO3-x Ny can promote the activity of Fe and Ni catalysts, while electron donation and suppression of hydrogen poisoning by BaTiO3-x Hx are significant in the Ru and Co systems.

17.
Med Dosim ; 48(3): 197-201, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37202230

RESUMO

This study aimed to compare dosimetric parameters for targets and organs at risk (OARs) between volumetric modulated arc therapy (VMAT) and automated VMAT (HyperArc, HA) plans in stereotactic radiotherapy for patients with cervical metastatic spine tumors. VMAT plans were generated for 11 metastases using the simultaneous integrated boost technique to deliver 35 to 40 and 20 to 25 Gy for high dose and elective dose planning target volume (PTVHD and PTVED), respectively. The HA plans were retrospectively generated using 1 coplanar and 2 noncoplanar arcs. Subsequently, the doses to the targets and OARs were compared. The HA plans provided significantly higher (p < 0.05) Dmin (77.4 ± 13.1%), D99% (89.3 ± 8.9%), and D98% (92.5 ± 7.7%) for gross tumor volume (GTV) than those of the VMAT plans (73.4 ± 12.2%, 84.2 ± 9.6 and 87.3 ± 8.8% for Dmin, D99% and D98%, respectively). In addition, D99% and D98% for PTVHD were significantly higher in the HA plans, whereas dosimetric parameters were comparable between the HA and VMAT plans for PTVED. The Dmax values for the brachial plexus, esophagus, and spinal cord were comparable, and no significant difference was observed in the Dmean for the larynx, pharyngeal constrictor, thyroid, parotid grand (left and right), and Submandibular gland (left and right). The HA plans provided significantly higher target coverage of GTV and PTVHD, with a comparable dose for OARs with VMAT plans. The results of this study may contribute to the improvement of local control in clinical practice.

18.
Radiol Phys Technol ; 16(2): 310-318, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37093409

RESUMO

To compare the dosimetric parameters of automated noncoplanar volumetric modulated arc therapy plans using single-isocentric (SIC) and multi-isocentric (MIC) techniques for patients with two brain metastases (BMs) in stereotactic irradiation and to evaluate the robustness of rotational errors. The SIC and MIC plans were retrospectively generated (35 Gy/five fractions) for 58 patients. Subsequently, a receiver operating characteristic curve analysis between the tumor surface distance (TSD) and V25Gy was performed to determine the thresholds for the brain tissue. The SIC and MIC plans were recalculated based on the rotational images to evaluate the dosimetric impact of rotational error. The MIC plans showed better brain tissue sparing for TSD > 6.6 cm. The SIC plans provided a significantly better conformity index for TSD ≤ 6.6 cm, while significantly lower gradient index was obtained (3.22 ± 0.56vs. 3.30 ± 0.57, p < 0.05) in the MIC plans with TSD > 6.6 cm. For organs at risk (OARs) (brainstem, chiasm, lens, optic nerves, and retinas), D0.1 cc was significantly lower (p < 0.05) in the MIC plans than in the SIC plans. The prescription dose could be delivered (D99%) to the gross tumor volume (GTV) for patients with TSD ≤ 6.6 cm when the rotational error was < 1°, whereas 31% of the D99% of GTV fell below the prescription dose with TSD > 6.6 cm. MIC plans can be an optimal approach for reducing doses to OARs and providing robustness against rotational errors in BMs with TSD > 6.6 cm.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/patologia , Órgãos em Risco , Radiocirurgia/métodos
19.
J Am Chem Soc ; 145(17): 9410-9416, 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-36995761

RESUMO

CO2 hydrogenation to methanol is one of the most promising routes to CO2 utilization. However, difficulty in CO2 activation at low temperature, catalyst stability, catalyst preparation, and product separation are obstacles to the realization of a practical hydrogenation process under mild conditions. Here, we report a PdMo intermetallic catalyst for low-temperature CO2 hydrogenation. This catalyst can be synthesized by the facile ammonolysis of an oxide precursor and exhibits excellent stability in air and the reaction atmosphere and significantly enhances the catalytic activity for CO2 hydrogenation to methanol and CO compared with a Pd catalyst. A turnover frequency of 0.15 h-1 was achieved for methanol synthesis at 0.9 MPa and 25 °C, which is comparable to or higher than that of the state-of-the-art heterogeneous catalysts under higher-pressure conditions (4-5 MPa).

20.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(3): 252-261, 2023 Mar 20.
Artigo em Japonês | MEDLINE | ID: mdl-36709971

RESUMO

PURPOSE: The questionnaire survey investigated whether "Explainer videos about radiation therapy (RT-Video)", "Treatment of breast cancer patients by female radiation therapists (F-RTT)" and "Treating male patients while wearing underwear in pelvic radiation therapy (M-RTT)" can improve patient's satisfaction. METHODS: The RT-Video survey included questions regarding the impression of radiation therapy, improving its understanding, and anxiety reduction (102 patients received radiation therapy). Fifty-one breast cancer patients were asked whether they preferred an F-RTT treatment. Subsequently, the patients treated with F-RTT (41 patients) and M-RTT (50 patients) were surveyed about their treatment satisfaction on a five-point scale. RESULTS: RT-Video improved the understanding of radiation therapy for 86 out of 102 patients (84%). In all, 68 out of 102 patients (68%) had a negative impression of radiotherapy; among them, watching the RT-Video reduced anxiety in 63% of patients. A total of 14 out of 51 breast cancer patients (28%) preferred the F-RTT treatment. The percentage of patients who received treatment satisfaction by F-RTT and M-RTT was 95% and 84%, respectively. CONCLUSION: RT-Video, F-RTT and M-RTT treatments improved patients' satisfaction.


Assuntos
Neoplasias da Mama , Radioterapia (Especialidade) , Humanos , Masculino , Feminino , Satisfação do Paciente , Neoplasias da Mama/radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...