Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Jpn J Ophthalmol ; 67(2): 182-188, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36626079

RESUMO

PURPOSE: To determine the influence of stimulating electrode conditions on the amplitudes and latencies of electrically evoked potentials (EEPs) and the resistance at the electrode-tissue interface in the suprachoroidal transretinal stimulation (STS) system. STUDY DESIGN: Experimental study. METHODS: A scleral pocket (3 × 5 mm) was created just over the visual streak in anesthetized pigmented rabbits (weight, 1.9-2.7 kg), and STS stimulating electrodes were implanted into the pocket. Measurements were obtained with stimulating electrodes of different lengths (0.3 or 0.5 mm) and different surface characteristics (smooth or porous). EEPs elicited with a fixed current under each set of electrode conditions were recorded; three measurement sessions were performed for each rabbit. The resistance at each electrode-tissue interface was measured. RESULTS: The latencies and amplitudes of the EEPs did not differ significantly with changes in the height and surface characteristics of the stimulating electrodes, but the resistances at the electrode-tissue interface differed significantly (P = 0.001; the resistance values for the 0.3-mm-long electrode with a porous surface was 5.24 ± 0.67 kΩ and with the 0.3- and 0.5-mm-long electrodes with smooth surfaces were 7.63 ± 0.12 kΩ and 6.77 ± 0.20 kΩ). CONCLUSION: Being shorter did not affect the EEPs of the stimulating electrodes with a porous surface while decreasing the resistance at the electrode-tissue interface.


Assuntos
Potenciais Evocados Visuais , Retina , Animais , Coelhos , Eletrodos Implantados , Estimulação Elétrica , Potenciais Evocados
2.
Front Neurosci ; 15: 717429, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720855

RESUMO

Retinal prostheses are devices used to restore visual sensation in patients suffering from photoreceptor degeneration, such as retinitis pigmentosa. Suprachoroidal-transretinal stimulation (STS) is a prosthesis with retinal electrodes located in the sclera. STS has the advantage that it is safer than epiretinal or subretinal prostheses, as the implant is not directly attached to the retinal tissue. We have previously reported feasibility of STS with animal experiments and clinical trials. However, functional evaluation with neurophysiological experiments is still largely missing. To estimate the spatial resolution of STS, single-unit activities in response to STS were recorded from relay cells in the dorsal lateral geniculate nucleus of cats, and the response probability of the units was analyzed in relation to the distance between the stimulus location and the receptive field of each recorded unit. A platinum electrode was attached to the sclera after lamellar resection, and the return electrode was placed in the vitreous. The stimulating current, which ranged from 50 to 500 µA, was applied between these electrodes, and the probability of spike responses occurring just after retinal stimulation was measured. The distance at half-maximum of response was determined from the collected response probabilities as a function of stimulus intensity for all units characterized by their distances from the receptive field center to the stimulation point. As the stimulation became weaker, this distance decreased to 1.8° at 150 and 100 µA. As another estimation, the radius of 25% response probability was 1.4° at 100 µA. The diameter of the stimulated cat retinal area, 3.6° or 2.8°, corresponds to human visual acuity of 0.005 or 0.007, or finger counting. Considering the lower hazard to the retina of STS and its potentially large visual field coverage, STS is an attractive method for retinal prosthetic device development.

3.
Transl Vis Sci Technol ; 10(3): 13, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34003947

RESUMO

Purpose: This study was conducted to investigate the feasibility of a newly developed wide-field dual-array suprachoroidal-transretinal stimulation (STS) prosthesis in dogs and to examine its biocompatibility and stability over a 4-month period. Methods: Three types of STS dual arrays were designed and tested. The STS dual-array was implanted into a scleral pocket of the left eye of six healthy beagle dogs. Ophthalmic examinations, fundus photography, fluorescein angiography (FA), electroretinography (ERG), and functional testing of this system were conducted postoperatively. The dogs were euthanatized at the end of the experiment, and their eyes were enucleated and histologically examined. Results: All prostheses were successfully implanted without complications, and no serious adverse event occurred during the postoperative period. Fundus photographs and FA showed no serious damage in the retina surrounding the arrays. The ERGs recorded from the implanted eyes showed no significant differences from those from control eyes. Histological evaluations demonstrated good preservation of the retina over the array. However, system failure occurred in 50% of the dogs owing to dog-specific habits. Conclusions: Implantation of this prosthesis system in dogs is feasible and can be performed without significant damage to the eye. The biocompatibility and stability of the array were good during the observation period, but the low durability of the system against dogs (not humans) is an issue to be resolved in the future. Translational Relevance: This study suggests that this wide-field dual-array prosthesis might widen the visual field and might be useful for patients with retinitis pigmentosa.


Assuntos
Próteses Visuais , Animais , Cães , Estimulação Elétrica , Eletrodos Implantados , Eletrorretinografia , Potenciais Evocados Visuais , Humanos
4.
Invest Ophthalmol Vis Sci ; 61(13): 38, 2020 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-33252633

RESUMO

Purpose: This study aimed to evaluate differences in objective and subjective accommodation dynamically and simultaneously. Methods: Thirty-four pre-presbyopic healthy volunteers (mean age ± SD, 41.0 ± 3.2 years) participated in this study. Initially, the reaction time for detecting a change in the target was measured at near. Dynamic accommodation was then monocularly recorded using an open-view Shack-Hartmann aberrometer and compared with the amplitude and velocity of subjective accommodation. Results: The objective amplitude of accommodation (0.97 ± 0.32 diopter [D]) was significantly greater than the subjective amplitude of accommodation (0.62 ± 0.43 D; P < 0.001). The accommodative velocity was significantly faster for the "before the accommodation" response time (0.47 ± 0.38 D/s) than the "after the accommodation" response time (0.21 ± 0.22 D/s; P = 0.007). Conclusions: The human eye under the monocular condition quickly adjusts to the focal plane to clearly archive the nearby object, and the focal plane thereafter is slowly and accurately adjusted to the visual target after visual recognition.


Assuntos
Acomodação Ocular/fisiologia , Presbiopia/fisiopatologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Pupila/fisiologia , Tempo de Reação , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
5.
PLoS One ; 15(3): e0230788, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32214343

RESUMO

PURPOSE: The purpose of this study was to evaluate the degree of visual fatigue in patients with intermittent exotropia (IXT) using the binocular fusion maintenance (BFM) test. METHODS: Fourteen patients with IXT (32.1 ± 16.4 years) and 15 age-matched healthy volunteers (31.2 ± 9.3 years) participated in the study. BFM was assessed by measuring the transmittance of liquid crystals placed in front of the subject's nondominant eye at the instance when binocular fusion was broken and vergence eye movement was induced. A questionnaire on subjective symptoms was administered to the subjects before and after the visual task. The visual task consisted of a reciprocal movement between 67 and 40 cm. RESULTS: The change [post-pre] of BFM was significantly lower in the IXT group (-0.185 ± 0.187) than in the control group (-0.030 ± 0.070) (P = 0.010). The change of total subjective eye symptom score was significantly greater in the IXT group (2.28 ± 1.43) than in the control group (0.93 ± 1.27) (P = 0.018). The reduction in BFM rate with increasing total subjective eye symptom score was significantly greater in the IXT group (-0.106 ± 0.017) than in the control group (-0.030 ± 0.013) (P = 0.006). CONCLUSION: The present findings objectively showed that patients with IXT are at a greater risk of visual fatigue in comparison with healthy individuals.


Assuntos
Exotropia/fisiopatologia , Visão Ocular , Adolescente , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
6.
J Binocul Vis Ocul Motil ; 70(1): 15-20, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31846597

RESUMO

Purpose: To evaluate binocular coordination using video-oculography (VOG) during smartphone reading in patients with esophoria (EP) compared with control subjects.Patients and methods: Ten young and adult patients with EP (25.3 ± 7.3 years) and seven orthophoric or small-angle exophoric control subjects (25.7 ± 4.8 years) were examined. Eye movements were recorded during smartphone reading at 20, 30, and 50 cm using VOG. Differences in the horizontal fixation disparity at each distance between and within the groups were analyzed.Results: Horizontal esodeviation at 20 cm in the EP group (1.23° ± 2.00°) was significantly greater than that at 30 cm (-0.39° ± 0.73°; P = .027) and was significantly greater than horizontal exodeviation at 20 cm in the control group (-0.21° ± 0.17°; P < .001).Conclusion: The current findings suggest that the horizontal fixation disparities in the patients with EP deviate to eso-direction during smartphone use.


Assuntos
Esotropia/fisiopatologia , Leitura , Smartphone , Visão Binocular/fisiologia , Acomodação Ocular/fisiologia , Adolescente , Adulto , Criança , Exotropia/fisiopatologia , Movimentos Oculares/fisiologia , Feminino , Humanos , Masculino , Gravação em Vídeo , Disparidade Visual/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem
7.
Ergonomics ; 62(6): 759-766, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30773103

RESUMO

This study aimed to evaluate objective and subjective visual fatigue experienced before and after performing a visual task while using a head-mounted display for virtual reality (VR-HMD) and two-dimensional (2D) display. Binocular fusion maintenance (BFM) was measured using a binocular open-view Shack-Hartmann wavefront aberrometer equipped with liquid crystal shutters. Twelve healthy subjects performed the BFM test and completed a questionnaire regarding subjective symptoms before and after performing a visual task that induces low visually induced motion sickness (VIMS). BFM (p = .87) and total subjective eye symptom scores (p = .38) were not significantly different between both groups, although these values were significantly lower after the visual task than before the task within both groups (p < .05). These findings suggest that visual fatigue after using a VR-HMD is not significantly different from that after using a 2D display in the presence of low-VIMS VR content. Practitioner summary: Objective and subjective evaluation of visual fatigue were not significantly different with the use of a head-mounted display for virtual reality (VR-HMD) and two-dimensional display. These results should be valuable not only to engineers developing VR content but also to researchers involved in the evaluation of visual fatigue using VR-HMD. Abbreviations: VR: virtual reality; VR-HMD: head-mounted display for virtual reality; BFM: binocular fusion maintenance; BWFA: binocular open-view Shack-Hartmann wavefront aberrometer.


Assuntos
Fadiga Mental/psicologia , Óculos Inteligentes/psicologia , Interface Usuário-Computador , Realidade Virtual , Percepção Visual , Adulto , Feminino , Humanos , Masculino , Análise e Desempenho de Tarefas
8.
AIMS Neurosci ; 6(4): 240-249, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32341980

RESUMO

It is well known that various types of information can be learned and memorized via repetitive training. In brain information science, it is very important to determine how neuronal networks comprising neurons with fluctuating characteristics reliably learn and memorize information. The aim of this study is to investigate the learning process in cultured neuronal networks and to address the question described above. Previously, we reported that the spikes resulting from stimulation at a specific neuron propagate as a cluster of excitation waves called spike wave propagation in cultured neuronal networks. We also reported that these waves have an individual spatiotemporal pattern that varies according to the type of neuron that is stimulated. Therefore, different spike wave propagations can be identified via pattern analysis of spike trains at particular neurons. Here, we assessed repetitive stimulation using intervals of 0.5 and 1.5 ms. Subsequently, we analyzed the relationship between the repetition of the stimulation and the identification of the different spike wave propagations. We showed that the various spike wave propagations were identified more precisely after stimulation was repeated several times using an interval of 1.5 ms. These results suggest the existence of a learning process in neuronal networks that occurs via repetitive training using a suitable interval.

9.
Clin Ophthalmol ; 12: 2069-2078, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30425446

RESUMO

PURPOSE: This study aimed to evaluate binocular coordination using video-oculography during smartphone reading in patients with intermittent exotropia compared to individuals with normal vision. PATIENTS AND METHODS: Eleven youth and adult patients with intermittent exotropia (21.9±9.3 years) and 15 control subjects (26.6±4.3 years) were examined. Eye movements were recorded during smartphone reading at 50, 30, and 20 cm using video-oculography. The loss of binocular coordination was tentatively defined as a horizontal disparity greater than 2°. The proportion of monocular viewing was the percentage of time for which binocularity was lost during smartphone reading. The proportion of monocular viewing, the reading speed, and the correlation between proportion of monocular viewing and reading speed were analyzed. RESULTS: The proportion of monocular viewing during smartphone reading was significantly higher in the intermittent exotropia group than in the control group (P<0.001). It was significantly more frequent at 20 cm than at 50 cm in the intermittent exotropia group (P<0.05). The reading speed was significantly negatively correlated with the proportion of monocular viewing at 30 and 20 cm in the intermittent exotropia group (P<0.05). CONCLUSION: A significant increase in the proportion of monocular viewing in the intermittent exotropia group suggests that an appropriate viewing distance should be advised so that users can maintain binocular coordination when viewing a smartphone.

10.
Transl Vis Sci Technol ; 7(2): 9, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29600117

RESUMO

PURPOSE: In this study, we investigated whether an individual's visual fatigue can be evaluated objectively and quantitatively from their ability to maintain binocular fusion. METHODS: Binocular fusion maintenance (BFM) was measured using a custom-made binocular open-view Shack-Hartmann wavefront aberrometer equipped with liquid crystal shutters, wherein eye movements and wavefront aberrations were measured simultaneously. Transmittance in the liquid crystal shutter in front of the subject's nondominant eye was reduced linearly, and BFM was determined from the transmittance at the point when binocular fusion was broken and vergence eye movement was induced. In total, 40 healthy subjects underwent the BFM test and completed a questionnaire regarding subjective symptoms before and after a visual task lasting 30 minutes. RESULTS: BFM was significantly reduced after the visual task (P < 0.001) and was negatively correlated with the total subjective eye symptom score (adjusted R2 = 0.752, P < 0.001). Furthermore, the diagnostic accuracy for visual fatigue was significantly higher in BFM than in the conventional test results (aggregated fusional vergence range, near point of convergence, and the high-frequency component of accommodative microfluctuations; P = 0.007). CONCLUSIONS: These results suggest that BFM can be used as an indicator for evaluating visual fatigue. TRANSLATIONAL RELEVANCE: BFM can be used to evaluate the visual fatigue caused by the new visual devices, such as head-mount display, objectively.

11.
AIMS Neurosci ; 5(1): 18-31, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-32341949

RESUMO

Neuronal networks have fluctuating characteristics, unlike the stable characteristics seen in computers. The underlying mechanisms that drive reliable communication among neuronal networks and their ability to perform intelligible tasks remain unknown. Recently, in an attempt to resolve this issue, we showed that stimulated neurons communicate via spikes that propagate temporally, in the form of spike trains. We named this phenomenon "spike wave propagation". In these previous studies, using neural networks cultured from rat hippocampal neurons, we found that multiple neurons, e.g., 3 neurons, correlate to identify various spike wave propagations in a cultured neuronal network. Specifically, the number of classifiable neurons in the neuronal network increased through correlation of spike trains between current and adjacent neurons. Although we previously obtained similar findings through stimulation, here we report these observations on a physiological level. Considering that individual spike wave propagation corresponds to individual communication, a correlation between some adjacent neurons to improve the quality of communication classification in a neuronal network, similar to a diversity antenna, which is used to improve the quality of communication in artificial data communication systems, is suggested.

12.
Ophthalmic Surg Lasers Imaging Retina ; 48(2): 106-113, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28195612

RESUMO

BACKGROUND AND OBJECTIVE: To investigate the relationship between spatial contrast sensitivity (CS) and parafoveal cone density (PCD). PATIENTS AND METHODS: Fifteen healthy individuals (mean age: 26.1 years ± 4.5 years) and nine patients with hereditary retinal degeneration (mean age: 31.6 years ± 13.4 years) without media opacities were studied. The CS was measured by CSV-1000 (VectorVision, Greenville, OH). The cone mosaic was photographed with an adaptive optics scanning laser ophthalmoscope (AOSLO) with a 1° × 1° field of view centered on the fovea. The PCD was calculated in an annular area with radii of 0.38° and 0.43°. The CS was converted to the logarithm (logCS), and the area under the logCS function (AULCSF) was determined. RESULTS: The AULCSF was significantly and positively correlated with the PCD in the control (R2 = 0.522; P = .003) and retinal degeneration (R2 = 0.514; P = .03) groups. CONCLUSION: PCD can predict the spatial contrast sensitivity in normal subjects or patients with retinal degeneration without media opacities. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:106-113.].


Assuntos
Sensibilidades de Contraste/fisiologia , Fóvea Central/patologia , Células Fotorreceptoras Retinianas Cones/patologia , Degeneração Retiniana/fisiopatologia , Adolescente , Adulto , Contagem de Células , Criança , Feminino , Angiofluoresceinografia , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Degeneração Retiniana/diagnóstico , Tomografia de Coerência Óptica/métodos , Adulto Jovem
13.
Comput Intell Neurosci ; 2016: 7267691, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27217825

RESUMO

We observed spike trains produced by one-shot electrical stimulation with 8 × 8 multielectrodes in cultured neuronal networks. Each electrode accepted spikes from several neurons. We extracted the short codes from spike trains and obtained a code spectrum with a nominal time accuracy of 1%. We then constructed code flow maps as movies of the electrode array to observe the code flow of "1101" and "1011," which are typical pseudorandom sequence such as that we often encountered in a literature and our experiments. They seemed to flow from one electrode to the neighboring one and maintained their shape to some extent. To quantify the flow, we calculated the "maximum cross-correlations" among neighboring electrodes, to find the direction of maximum flow of the codes with lengths less than 8. Normalized maximum cross-correlations were almost constant irrespective of code. Furthermore, if the spike trains were shuffled in interval orders or in electrodes, they became significantly small. Thus, the analysis suggested that local codes of approximately constant shape propagated and conveyed information across the network. Hence, the codes can serve as visible and trackable marks of propagating spike waves as well as evaluating information flow in the neuronal network.


Assuntos
Potenciais de Ação/fisiologia , Modelos Neurológicos , Rede Nervosa/fisiologia , Neurônios/fisiologia , Animais , Técnicas de Cultura de Células , Estimulação Elétrica , Embrião de Mamíferos , Hipocampo/citologia , Ratos , Ratos Wistar
14.
Comput Intell Neurosci ; 2016: 7186092, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27239189

RESUMO

It has been shown that, in cultured neuronal networks on a multielectrode, pseudorandom-like sequences (codes) are detected, and they flow with some spatial decay constant. Each cultured neuronal network is characterized by a specific spectrum curve. That is, we may consider the spectrum curve as a "signature" of its associated neuronal network that is dependent on the characteristics of neurons and network configuration, including the weight distribution. In the present study, we used an integrate-and-fire model of neurons with intrinsic and instantaneous fluctuations of characteristics for performing a simulation of a code spectrum from multielectrodes on a 2D mesh neural network. We showed that it is possible to estimate the characteristics of neurons such as the distribution of number of neurons around each electrode and their refractory periods. Although this process is a reverse problem and theoretically the solutions are not sufficiently guaranteed, the parameters seem to be consistent with those of neurons. That is, the proposed neural network model may adequately reflect the behavior of a cultured neuronal network. Furthermore, such prospect is discussed that code analysis will provide a base of communication within a neural network that will also create a base of natural intelligence.


Assuntos
Simulação por Computador , Modelos Neurológicos , Rede Nervosa/fisiologia , Neurônios/fisiologia , Potenciais de Ação/fisiologia , Algoritmos , Animais , Técnicas de Cultura de Células , Humanos , Redes Neurais de Computação , Transmissão Sináptica
15.
Jpn J Ophthalmol ; 60(4): 326-32, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27112342

RESUMO

PURPOSE: To determine the relationship between re-reading the same line and saccadic disconjugacy in patients with convergence insufficiency-type intermittent exotropia [CI-type X(T)]. METHODS: Eight patients with CI-type X(T) and ten healthy orthophoric individuals were studied. Video-oculography was used to assess the eye movements during the reading of a Japanese novel displayed on a 23-in. liquid crystal monitor placed 60 cm from the eyes. The sentences were displayed horizontally and read from left to right. The number of unintentional re-readings of the same line was counted, and the disconjugacy at the median of the saccade between the end of a line and the next line was determined. RESULTS: The number of re-readings of the same line in patients with CI-type X(T) was 4.9 ± 2.3 times which was significantly higher than that in the controls at 0.2 ± 0.4 times (P < 0.001). The saccadic disconjugacy was significantly larger in patients with CI-type X(T) at -1.70° ± 0.72° than that in the controls at -0.40°± 0.30° (P < 0.001). The number of re-readings of the same line was significantly and positively correlated with the saccadic disconjugacy (R = 0.84, R (2) = 0.71, P < 0.01). CONCLUSIONS: The results of our study indicate that saccadic disconjugacy is associated with re-reading the same line in patients with CI-type X(T).


Assuntos
Exotropia/fisiopatologia , Transtornos da Motilidade Ocular/fisiopatologia , Leitura , Movimentos Sacádicos/fisiologia , Visão Binocular , Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
16.
Transfusion ; 56(5): 1171-81, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26868047

RESUMO

BACKGROUND: The Jr(a) antigen of JR blood group systems is located on ABCG2 and Jr(a-) subjects whose red blood cells (RBCs) lack ABCG2 have been identified mostly among the Japanese. Although anti-Jr(a) can cause fetal anemia, little is known regarding its mechanism. STUDY DESIGN AND METHODS: We reviewed clinical courses of all reported cases with fetal anemia due to anti-Jr(a) . We analyzed the ABCG2 expressions of cord RBCs at various gestational ages. We examined the effects of sera containing anti-Jr(a) from three pregnancies with fetal anemia or monoclonal anti-Jr(a) on erythropoiesis and phagocytosis. We also examined epitopes of anti-Jr(a) . RESULTS: Case series suggested that the majority of fetal anemia with anti-Jr(a) may not be progressive in the later gestational ages. ABCG2 expression levels of cord RBCs were significantly higher than those of adults and neonates with high individual variation and gradually decreased with advancing gestational ages. Anti-Jr(a) did not significantly impact erythroid colony formation, although we detected a tendency toward the suppression of erythroid burst-forming unit formation by anti-Jr(a) using feline marrow cells. Anti-Jr(a) did not induce phagocytosis of sensitized RBCs by monocytes. While many anti-Jr(a) recognized the same regions as a monoclonal anti-ABCG2, 5D3, epitopes of anti-Jr(a) did not correlate with the incidence of fetal anemia. CONCLUSION: ABCG2 expression levels in cord RBCs are higher than those of adults, and the change of ABCG2 expression in erythroid lineage cells may influence the clinical course of fetal anemia with anti-Jr(a) , although we could not detect significant effects of anti-Jr(a) on erythroid colony formation or phagocytosis.


Assuntos
Membro 2 da Subfamília G de Transportadores de Cassetes de Ligação de ATP/imunologia , Anemia Neonatal/imunologia , Proteínas de Neoplasias/imunologia , Membro 2 da Subfamília G de Transportadores de Cassetes de Ligação de ATP/análise , Membro 2 da Subfamília G de Transportadores de Cassetes de Ligação de ATP/metabolismo , Adulto , Anemia Neonatal/etiologia , Animais , Antígenos de Grupos Sanguíneos/imunologia , Gatos , Células Cultivadas , Eritrócitos/imunologia , Feminino , Sangue Fetal/citologia , Idade Gestacional , Humanos , Recém-Nascido , Proteínas de Neoplasias/análise , Proteínas de Neoplasias/metabolismo , Gravidez , Adulto Jovem
17.
Graefes Arch Clin Exp Ophthalmol ; 254(4): 661-73, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26194404

RESUMO

PURPOSE: To investigate the safety and efficacy of a newly-developed wide-field dual-array suprachoroidal-transretinal stimulation (STS) prosthesis in middle-sized animals. METHODS: The prosthesis consisted of two arrays with 50 to 74 electrodes. To test the feasibility of implanting the prosthesis and its efficacy, the prosthesis was implanted for 14 days into two rabbits. Optical coherence tomography (OCT) and ophthalmoscopy were performed 7 and 14 days after the implantation. Then the rabbits were euthanized, eyes were enucleated, and the posterior segment of the eye was examined histologically. In a second experiment, the arrays were implanted into two cats, and their ability to elicit neural responses was determined by electrically evoked potentials (EEPs) at the chiasm and by optical imaging of the retina. RESULTS: All arrays were successfully implanted, and no major complications occurred during the surgery or during the 2-week postoperative period. Neither OCT nor ophthalmoscopy showed any major complications or instability of the arrays. Histological evaluations showed only mild cellular infiltration and overall good retinal preservation. Stimulation of the retina by the arrays evoked EEPs recorded from the chiasm. Retinal imaging showed that the electrical pulses from the arrays altered the retinal images indicating an activation of retinal neurons. The thresholds were as low as 100 µA for a chiasm response and 300 µA for the retinal imaging. CONCLUSION: Implantation of a newly-developed dual-array STS prosthesis for 2 weeks in rabbits was feasible surgically, and safe. The results of retinal imaging showed that the dual-array system was able to activate retinal neurons. We conclude that the dual-array design can be implanted without complication and is able to activate retinal neurons and optic nerve axons.


Assuntos
Eletrodos Implantados , Potenciais Evocados Visuais/fisiologia , Implantação de Prótese , Neurônios Retinianos/fisiologia , Próteses Visuais , Animais , Materiais Biocompatíveis , Gatos , Terapia por Estimulação Elétrica , Eletrorretinografia , Estudos de Viabilidade , Angiofluoresceinografia , Teste de Materiais , Microeletrodos , Coelhos , Retina/fisiologia , Retina/cirurgia , Tomografia de Coerência Óptica , Córtex Visual/fisiologia
18.
PLoS One ; 10(6): e0131485, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26121666

RESUMO

To investigate the changes in the reflectance of human cone photoreceptors by an adaptive optics scanning laser ophthalmoscope (AO-SLO) during photobleaching. A custom-built AO-SLO with an observation light of 840-nm was used to measure the cone densities and the reflectance changes during bleaching by 630 nm red light emitting diodes. Measurements were made at 1° and 3° temporal to the fovea within an area of 1° × 1° in 8 eyes of 8 normal subjects. After dark-adaptation, images of the cone mosaics were recorded continuously for 5-min before, 5-min during, and after 5-min of light stimulation with a sampling rate of 5-Hz. The first positive peak (P1) was observed at 72.2 ± 15.0-s and a second positive peak (P2) at 257.5 ± 34.5-s at 1°. The increase of the reflectance of P1 was significantly larger at 1° (34.4 ± 13.9%) than at 3° (26.0 ± 10.5%; P = 0.03, Wilcoxon's signed rank test). The average cone density at 1° (51123.13 ± 1401.23 cells/mm2) was significantly larger than that at 3° (30876.13 ± 1459.28 cells/mm2; P <0.001, Wilcoxon's signed rank test). The changes in the reflectance of the cones during bleaching by red light had two peaks. The two peaks may be caused by regeneration of cone photopigment during bleaching.


Assuntos
Adaptação Ocular/efeitos da radiação , Lasers , Oftalmoscópios , Óptica e Fotônica/instrumentação , Fotodegradação , Células Fotorreceptoras Retinianas Cones/fisiologia , Células Fotorreceptoras Retinianas Cones/efeitos da radiação , Adulto , Fóvea Central , Humanos , Estimulação Luminosa , Fatores de Tempo , Adulto Jovem
19.
PLoS One ; 9(8): e105615, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25144536

RESUMO

To investigate the changes in the wavefront aberrations and pupillary shape in response to electrical stimulation of the branches of the ciliary nerves in cats. Seven eyes of seven cats were studied under general anesthesia. Trains of monophasic pulses (current, 0.1 to 1.0 mA; duration, 0.5 ms/phase; frequency, 5 to 40 Hz) were applied to the lateral or medial branch of the short ciliary nerve near the posterior pole of the eye. A pair of electrodes was hooked onto one or both branch of the short ciliary nerve. The electrodes were placed about 5 mm from the scleral surface. The wavefront aberrations were recorded continuously for 2 seconds before, 8 seconds during, and for 20 seconds after the electrical stimulation. The pupillary images were simultaneously recorded during the stimulation period. Both the wavefront aberrations and the pupillary images were obtained 10 times/sec with a custom-built wavefront aberrometer. The maximum accommodative amplitude was 1.19 diopters (D) produced by electrical stimulation of the short ciliary nerves. The latency of the accommodative changes was very short, and the accommodative level gradually increased up to 4 seconds and reached a plateau. When only one branch of the ciliary nerve was stimulated, the pupil dilated asymmetrically, and the oblique astigmatism and one of the asymmetrical wavefront terms was also altered. Our results showed that the wavefront aberrations and pupillary dilations can be measured simultaneously and serially with a compact wavefront aberrometer. The asymmetric pupil dilation and asymmetric changes of the wavefront aberrations suggest that each branch of the ciliary nerve innervates specific segments of the ciliary muscle and dilator muscle of the pupil.


Assuntos
Aberrometria , Estimulação Elétrica , Tecido Nervoso , Pupila/fisiologia , Animais , Gatos , Aberrações de Frente de Onda da Córnea/diagnóstico
20.
Jpn J Ophthalmol ; 58(4): 309-19, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24788459

RESUMO

PURPOSE: Our goal was to determine the feasibility of using electrochemically treated bulk platinum electrodes with large charge injection capacity for a retinal prosthesis. METHODS: Seven eyes of seven cats were studied. Small retinal areas were focally stimulated with electrochemically treated bulk electrodes (φ = 500 µm) placed in a scleral pocket. Fundus images with near-infrared (800-880 nm) light were recorded, and a 2D map of the reflectance changes elicited by the electrical currents was constructed by subtracting the images taken before stimulation from those taken after stimulation. The impedance of each electrode was measured at 1 kHz. The degree of retinal elevation by the electrode was measured by optical coherence tomography. Scleral thickness where the electrode array was inserted was measured in histologic sections. RESULTS: The diameter of reflectance changes (full width at half maximum) was 0.42 ± 0.22 mm [mean ± standard deviation (SD)] in minor axes and 1.46 ± 0.82 mm in major axes. The threshold current decreased with a reduction in the residual scleral thickness (R (2) = 0.9215; P = 0.0002); it also decreased with an increase in retinal elevation (R (2) = 0.6259; P = 0.0111).The threshold current also decreased with an increase in electrode impedance (R (2) = 0.2554; P = 0.0147). CONCLUSIONS: Electrochemically treated porous platinum electrodes can stimulate localized retinal areas. The threshold current necessary to stimulate the retina was influenced by residual scleral thickness and the electrode tightness of fit against the sclera.


Assuntos
Estimulação Elétrica , Eletrodos Implantados , Potenciais Evocados Visuais/fisiologia , Retina/fisiologia , Próteses Visuais , Animais , Gatos , Diagnóstico por Imagem , Impedância Elétrica , Técnicas Eletroquímicas , Feminino , Masculino , Microeletrodos , Quiasma Óptico/fisiologia , Estimulação Luminosa , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...