Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1118(1): 139-43, 2006 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-16635492

RESUMO

A technique for the speciation of selenomethylcysteine (SeMeCys), selenocystine (SeCys), selenite [Se(IV)] and selenomethionine (SeMet) was established in this paper using high-performance anion-exchange chromatography coupled with atomic fluorescence spectrometry (HPAEC-AFS). Analytes were separated on an AminoPac PA10 column and then digested by on-line ultraviolet (UV) irradiation, which destroyed organic compound structure. Hydride generation was used as an available sample introduction technique for atomic fluorescence detection. The detection limits of four compounds were 1-5 microg/L (250 microL injection, 10 times of the baseline noise). The relative standard deviations (RSDs), calculated from seven consecutive injections of 100 microg/L standard mixtures, were from 2 to 4%. Selenious yeast tablet, which had been proposed as selenium supplement, and human urine collected from a volunteer were analyzed. Good spiked recoveries from 86 to 103% were obtained.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Selênio/análise , Espectrometria de Fluorescência/métodos , Espectrofotometria Atômica/métodos , Cromatografia Líquida de Alta Pressão/instrumentação , Cistina/análogos & derivados , Cistina/análise , Humanos , Ácido Clorídrico/química , Resinas de Troca Iônica/química , Compostos Organosselênicos/análise , Compostos Organosselênicos/urina , Reprodutibilidade dos Testes , Selênio/urina , Selenometionina/análise , Selenometionina/urina , Hidróxido de Sódio/química , Selenito de Sódio/análise , Selenito de Sódio/urina , Espectrometria de Fluorescência/instrumentação , Espectrofotometria Atômica/instrumentação , Comprimidos/química , Raios Ultravioleta , Leveduras/química
2.
J Chromatogr A ; 1118(1): 134-8, 2006 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-16529758

RESUMO

Speciation analysis of selenomethylcysteine (SeMeCys), selenomethionine (SeMet) and selenocystine (SeCys) has been performed using a direct amino acid analysis method with high-performance anion-exchange chromatography (HPAEC) coupled with integrated pulsed amperometric detection (IPAD). Three selenoamino acids could be baseline-separated from 19 amino acids using gradient elution conditions for amino acids and determined under new six-potential waveform. Detection limits for SeMeCys, SeMet and SeCys were 0.25, 1 and 20 microg/L (25 microL injection, 10 times of the baseline noise), respectively. The relative standard deviations (RSDs) of 200 microg/L SeMeCys, SeMet and SeCys were 3.1, 4.1 and 2.8%, respectively (n=9, 25 microL injection). The proposed method has been applied for determination of selenoamino acids in extracts of garlic and selenious yeast granule samples. No selenoamino acids were found in garlic. Both SeMet and SeCys were detected in selenious yeast tablet with the content of 45 and 129 microg Se/g, respectively. Selenoamino acids standards were spiked in garlic and yeast granule samples and the recovery ranged from 90 to 106%.


Assuntos
Aminoácidos/análise , Resinas de Troca Aniônica/química , Cromatografia Líquida de Alta Pressão/métodos , Eletroquímica/métodos , Aminoácidos/isolamento & purificação , Cromatografia Líquida de Alta Pressão/instrumentação , Cistina/análogos & derivados , Cistina/análise , Cistina/isolamento & purificação , Eletroquímica/instrumentação , Alho/química , Compostos Organosselênicos/análise , Compostos Organosselênicos/isolamento & purificação , Reprodutibilidade dos Testes , Selenometionina/análise , Selenometionina/isolamento & purificação , Leveduras/química
3.
Se Pu ; 23(6): 677-80, 2005 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-16499005

RESUMO

Polarizable anions such as Br-, S2O3(2-), I- and SCN- were separated using 45 mmol/L sodium hydroxide solution as the mobile phase on a high hydrophilic IonPac AS16 column. With a pulsed amperometric detector, the detection limits were 0.5, 0.2, 0.05 and 2 microg/L (25.0 microL injected, signal-to-noise ratio of 3) for Br-, S2O3(2-), I- and SCN. The relative standard deviation (RSD) range of trace anions was from 0.8% to 3.7% (n = 9). Under the same chromatographic conditions, these anions were also determined using a suppressed conductivity detector and the detection limits were 1, 1, 2 and 10 microg/L (25 microL injected, signal-to-noise ratio of 3), respectively. The RSD range was from 0.9% to 4.7% (n = 9). Comparing a pulsed amperometric detector with a conductivity detector, the former is 2 to 40 times more sensitive than the latter. For the determination of polarizable anions, a pulsed amperometric detector has higher selectivity, precision and sensitivity.


Assuntos
Ânions/análise , Cromatografia Líquida de Alta Pressão/métodos , Resinas de Troca Aniônica , Reprodutibilidade dos Testes , Hidróxido de Sódio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...