Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 65(1): 125-131, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37884334

RESUMO

Implementation of radiopharmaceutical therapy dosimetry varies depending on the clinical application, dosimetry protocol, software, and ultimately the operator. Assessing clinical dosimetry accuracy and precision is therefore a challenging task. This work emphasizes some pitfalls encountered during a structured analysis, performed on a single-patient dataset consisting of SPECT/CT images by various participants using a standard protocol and clinically approved commercial software. Methods: The clinical dataset consisted of the dosimetric study of a patient administered with [177Lu]Lu-DOTATATE at Tygerberg Hospital, South Africa, as a part of International Atomic Energy Agency-coordinated research project E23005. SPECT/CT images were acquired at 5 time points postinjection. Patient and calibration images were reconstructed on a workstation, and a calibration factor of 122.6 Bq/count was derived independently and provided to the participants. A standard dosimetric protocol was defined, and PLANETDose (version 3.1.1) software was installed at 9 centers to perform the dosimetry of 3 treatment cycles. The protocol included rigid image registration, segmentation (semimanual for organs, activity threshold for tumors), and dose voxel kernel convolution of activity followed by absorbed dose (AD) rate integration to obtain the ADs. Iterations of the protocol were performed by participants individually and within collective training, the results of which were analyzed for dosimetric variability, as well as for quality assurance and error analysis. Intermediary checkpoints were developed to understand possible sources of variation and to differentiate user error from legitimate user variability. Results: Initial dosimetric results for organs (liver and kidneys) and lesions showed considerable interoperator variability. Not only was the generation of intermediate checkpoints such as total counts, volumes, and activity required, but also activity-to-count ratio, activity concentration, and AD rate-to-activity concentration ratio to determine the source of variability. Conclusion: When the same patient dataset was analyzed using the same dosimetry procedure and software, significant disparities were observed in the results despite multiple sessions of training and feedback. Variations due to human error could be minimized or avoided by performing intensive training sessions, establishing intermediate checkpoints, conducting sanity checks, and cross-validating results across physicists or with standardized datasets. This finding promotes the development of quality assurance in clinical dosimetry.


Assuntos
Neoplasias , Compostos Radiofarmacêuticos , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Radiometria/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Fígado
2.
J Nucl Med ; 63(2): 253-258, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34088773

RESUMO

The radiation dose to the kidneys should be monitored in prostate cancer patients treated with radioligand therapy (RLT) targeting the prostate-specific membrane antigen (PSMA). We analyzed whether pretherapeutic kidney function is predictive of subsequent kidney dose and to what extent the cumulative kidney dose at the end of multiple therapy cycles can be predicted from a dosimetry based on the first cycle. Methods: Data of 59 patients treated with at least 2 cycles of 177Lu-PSMA-617 (PSMA RLT) were analyzed. Treatment (median, 6 GBq/cycle) was performed at 6- to 8-wk intervals, accompanied by voxel-based 3-dimensional dosimetry (measured kidney dose) with SPECT/CT on each of days 0-3 and once during days 6-9. Pretherapeutic kidney function (estimated glomerular filtration rate, mercaptoacetyltriglycine clearance) was correlated to the kidney doses. Cumulative kidney doses at the end of treatment were compared with a dose estimated from the population-based mean kidney dose, individual first-cycle kidney dose, and mean kidney doses of cycles 1, 3, and 5 per administered activity. Results: In total, 176 PSMA RLT cycles were performed, with a median of 3 cycles per patient. The average kidney dose per administered activity of all 176 cycles was 0.67 ± 0.24 Gy/GBq (range, 0.21-1.60 Gy/GBq). Mercaptoacetyltriglycine clearance and estimated glomerular filtration rate were no reliable predictors of subsequent absorbed kidney dose and showed only small effect sizes (R 2 = 0.080 and 0.014 [P = 0.039 and 0.375], respectively). All simplified estimations of cumulative kidney dose correlated significantly (P < 0.001) with measured kidney doses: estimations based on the individual first-cycle dose were more accurate than the use of the population-based average kidney dose (R 2 = 0.853 vs. 0.560). Dose estimation was best when the doses of cycles 3 and 5 were included as well (R 2 = 0.960). Conclusion: Pretherapeutic renal function was not predictive of subsequent kidney dose during therapy. Extrapolation of individual data from dosimetry of the first cycle was highly predictive of the cumulative kidney dose at the end of treatment. This prediction was further improved by the integration of dose information from every other cycle. In any case, because of a high interindividual variance, an individual dosimetry is advisable.


Assuntos
Lutécio , Neoplasias de Próstata Resistentes à Castração , Humanos , Rim , Masculino , Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Radiometria , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
3.
Phys Med ; 85: 24-31, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33957577

RESUMO

PURPOSE: Patient-specific dosimetry in MRT relies on quantitative imaging, pharmacokinetic assessment and absorbed dose calculation. The DosiTest project was initiated to evaluate the uncertainties associated with each step of the clinical dosimetry workflow through a virtual multicentric clinical trial. This work presents the generation of simulated clinical SPECT datasets based on GATE Monte Carlo modelling with its corresponding experimental CT image, which can subsequently be processed by commercial image workstations. METHODS: This study considers a therapy cycle of 6.85 GBq 177Lu-labelled DOTATATE derived from an IAEA-Coordinated Research Project (E23005) on "Dosimetry in Radiopharmaceutical therapy for personalised patient treatment". Patient images were acquired on a GE Infinia-Hawkeye 4 gamma camera using a medium energy (ME) collimator. Simulated SPECT projections were generated based on experimental time points and validated against experimental SPECT projections using flattened profiles and gamma index. The simulated projections were then incorporated into the patient SPECT/CT DICOM envelopes for processing and their reconstruction within a commercial image workstation. RESULTS: Gamma index passing rate (2% - 1 pixel criteria) between 95 and 98% and average gamma between 0.28 and 0.35 among different time points revealed high similarity between simulated and experimental images. Image reconstruction of the simulated projections was successful on HERMES and Xeleris workstations, a major step forward for the initiation of a multicentric virtual clinical dosimetry trial based on simulated SPECT/CT images. CONCLUSIONS: Realistic 177Lu patient SPECT projections were generated in GATE. These modelled datasets will be circulated to different clinical departments to perform dosimetry in order to assess the uncertainties in the entire dosimetric chain.


Assuntos
Radiometria , Tomografia Computadorizada de Emissão de Fóton Único , Câmaras gama , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...