J Orthop Traumatol ; 24(1): 46, 2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37665518

RESUMO

BACKGROUND: There is no evidence in the current literature about the best treatment option in sacral fracture with or without neurological impairment. MATERIALS AND METHODS: The Italian Pelvic Trauma Association (A.I.P.) decided to organize a consensus to define the best treatment for traumatic and insufficiency fractures according to neurological impairment. RESULTS: Consensus has been reached for the following statements: When complete neurological examination cannot be performed, pelvic X-rays, CT scan, hip and pelvis MRI, lumbosacral MRI, and lower extremities evoked potentials are useful. Lower extremities EMG should not be used in an acute setting; a patient with cauda equina syndrome associated with a sacral fracture represents an absolute indication for sacral reduction and the correct timing for reduction is "as early as possible". An isolated and incomplete radicular neurological deficit of the lower limbs does not represent an indication for laminectomy after reduction in the case of a displaced sacral fracture in a high-energy trauma, while a worsening and progressive radicular neurological deficit represents an indication. In the case of a displaced sacral fracture and neurological deficit with imaging showing no evidence of nerve root compression, a laminectomy after reduction is not indicated. In a patient who was not initially investigated from a neurological point of view, if a clinical investigation conducted after 72 h identifies a neurological deficit in the presence of a displaced sacral fracture with nerve compression on MRI, a laminectomy after reduction may be indicated. In the case of an indication to perform a sacral decompression, a first attempt with closed reduction through external manoeuvres is not mandatory. Transcondylar traction does not represent a valid method for performing a closed decompression. Following a sacral decompression, a sacral fixation (e.g. sacroiliac screw, triangular osteosynthesis, lumbopelvic fixation) should be performed. An isolated and complete radicular neurological deficit of the lower limbs represents an indication for laminectomy after reduction in the case of a displaced sacral fracture in a low-energy trauma associated with imaging suggestive of root compression. An isolated and incomplete radicular neurological deficit of the lower limbs does not represent an absolute indication. A worsening and progressive radicular neurological deficit of the lower limbs represents an indication for laminectomy after reduction in the case of a displaced sacral fracture in a low-energy trauma associated with imaging suggestive of root compression. In the case of a displaced sacral fracture and neurological deficit in a low-energy trauma, sacral decompression followed by surgical fixation is indicated. CONCLUSIONS: This consensus collects expert opinion about this topic and may guide the surgeon in choosing the best treatment for these patients. LEVEL OF EVIDENCE: IV. TRIAL REGISTRATION: not applicable (consensus paper).


Assuntos
Descompressão Cirúrgica , Fixação de Fratura , Fraturas Ósseas , Sacro , Humanos , Consenso , Fraturas Ósseas/cirurgia , Tração , Sacro/lesões , Sacro/cirurgia
2.
J Orthop Surg Res ; 18(1): 278, 2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37020227

RESUMO

PURPOSE: The use of dual mobility cups in total hip arthroplasty has gained popularity in light of the fact it enables to reduce dislocation through increased jumping distance (JD) and impingement-free arc of movement. Modular Dual Mobility Cup (modular DMC) systems have been recently introduced to enable the use of dual mobility cups with standard metal-backed shells. The objective of this study was twofold: calculate the JD for each modular DMC system and conduct a systematic literature review to report clinical outcomes and reasons for failure of this construct. METHODS: The JD was calculated using the Sariali formula: JD = 2Rsin [(π/2 - Ψ - arcsin (offset/R))/2]. A qualitative systematic literature review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search for English and French articles between January 2000 and July 2020 was run on PubMed, EMBASE, Google Scholar, and Scopus with the primary objective of finding articles about modular DMC systems. RESULTS: We identified eight 8 different manufacturers of modular DMC systems and 327 publications on the subject. After screening for duplicates and eligibility, we identified 229 publications: 206 articles were excluded because they contained no reports on modular DMC systems, whereas other three were not included because they focused on biomechanical aspects. Among the 11 included articles, 2 were prospective case series, 9 were retrospective case series. True dislocation occurred in 25 cases (0.9%), and six of them were solved by closed reduction without necessity of revision, while all 5 intraprosthetic dislocations were operated. CONCLUSIONS: Modular DMCs are a valid method to deal with complex THA instability, with good clinical and patient-reported outcomes, low complication rates, and low revision rates at early follow-up. We would advise cautious optimism on the role of modular DMC implants, as it seems safer to use ceramic instead of metallic heads whenever possible to avoid the increase cobalt and chromium trace ion serum levels.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Falha de Prótese , Desenho de Prótese , Reoperação/efeitos adversos , Luxação do Quadril/cirurgia , Luxações Articulares/cirurgia
3.
Int Orthop ; 47(1): 99-106, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36449052

RESUMO

PURPOSE: The purpose of the study was to investigate the outcome of dual-mobility cup (DM) compared with a standard cup (SC) in primary total hip arthroplasty (THA) in the long-term follow-up based on a regional Italian joint registry (RIPO). METHODS: The Registry of Prosthetic Orthopaedic Implant (RIPO) was consulted, looking for all primary THAs implanted from 2000 to 2019. Three thousand seven hundred ten were dual-mobility cup (DM) total hip arthroplasties (THA) and 85.816 were standard cup (SC) THAs, on a total of 89.526 primary THA. Demographics, survival rates and causes of revision were evaluated and compared between the two groups. RESULTS: The use of DM progressively increased from 0.4% in 2000 to 7.5% in 2018 of all primary THAs. Revision rate was 3.5% (128 on 3710) for DMC and 4.7% (4061 on 85,816) for SC. DM presented lower dislocation rate if compared to SC with 22-28-mm femoral head diameter. However, DM showed a higher risk of revision for any causes than SC with 32-mm femoral head diameter in long-term follow-up. Nevertheless, no significant difference was measured in terms of demographics and surgical approach for dislocation rate. CONCLUSIONS: The DM cup represents a valid implant solution and has a lower dislocation rate than 22-28-mm SC. A slight increase in the use of DM implants over time was observed in the RIPO. However, a larger population and a longer follow-up are needed to further monitor the survival rate of new-generation DM implants.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Luxações Articulares , Ortopedia , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Desenho de Prótese , Reoperação/efeitos adversos , Luxação do Quadril/cirurgia , Luxações Articulares/cirurgia , Sistema de Registros , Estudos Retrospectivos , Seguimentos
4.
Artif Organs ; 46(5): 804-812, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34153137

RESUMO

Although total hip arthroplasty (THA) has shown successful results, instability remains a major complication. In recent years, dual mobility cups (DMC) have gained interest among clinicians thanks to its low rate of dislocation and good clinical results. The main aim of this work was to describe the accuracy of data on DMC from national and regional joint registries (JRs) and the available worldwide literature. We identified topics on DMC among JRs to propose a new harmonized and standardized section for DMC with the aim to understand its surveillance over the time. We extracted survival and implant data for a separate analysis. After performing a critical exclusion process, nine JRs were considered eligible and included for final synthesis; these were the results from the available worldwide data from JRs. In our study, eight analyzed JRs reported a slight increase in DMC use in the last decade. In all the JRs evaluated and the available articles, dislocation remains one of the main reasons for revision and re-revision in hip arthroplasties. DMC is considered to be a valid construct increasingly used worldwide in primary and revision THA with the primary aim of reducing dislocation rates. Annual reports from JRs collect heterogeneous and low-quality information about outcomes and surveillance of DMC, creating a burden for clinicians to extract comparable data from different JRs. Longer follow-up and a systematic registering of DMCs with international registry harmonization are needed to monitor DMC outcomes.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Luxações Articulares , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Luxação do Quadril/complicações , Luxação do Quadril/cirurgia , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Luxações Articulares/cirurgia , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Reoperação , Estudos Retrospectivos
5.
Acta Biomed ; 90(1-S): 98-103, 2019 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-30715006

RESUMO

BACKGROUND AND AIM OF THE WORK: Partial or total hip replacement is the method of choice for displaced femoral neck fractures (FNF) treatment. Dislocation is a major complication, accounting for about 3.8% of cases for hemiarthroplasty (HA) and 10% for total hip arthroplasty (THA). Dual-mobility (DM) socket in total hip arthroplasty showed a very low rate of dislocation in both primary and revision setting THA. Some literature reports show good results with low dislocation rates also in FNF treatment at short term follow-up. Aim of the study was to evaluate clinical and radiographic results of DM-THA in FNF treatment at mid-term follow up. METHODS: Study population counted 31 implants in 30 patients treated with DM-THA for FNF between January 2010 and December 2012. Dislocation rate was identified, and HHS and OHS were completed. Twenty-four patients underwent also radiographic evaluation to assess cup integration and sings of loosening. RESULTS: No episodes of hip dislocation nor intraprosthetic dislocation were found. Other postoperative complications were recorded in 9,67%. HHS and OHS showed a mean value of 81,22 and 37,37, respectively. There were no cases of clinical and radiographic signs of implant loosening. CONCLUSIONS: The present study confirms the good clinical results, low complications and very low dislocation rate with DM THA for FNF treatment.


Assuntos
Artroplastia de Quadril/instrumentação , Fraturas do Colo Femoral/cirurgia , Luxações Articulares/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Feminino , Seguimentos , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Estudos Retrospectivos , Resultado do Tratamento
6.
Clin Cases Miner Bone Metab ; 13(1): 57-60, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27252749

RESUMO

Atypical femoral fractures are often associated with prolonged bisphosphonate use. The American Society for Bone and Mineral Research (ASBMR) has set the diagnosis criteria for atypical subtrochanteric and diaphyseal femoral fractures by classifying them according to their major and minor criteria. Prolonged bisphosphonate use is correlated with AFF, but the pathogenetic mechanism that causes this kind of fracture has not been defined yet. We describe simultaneous bilaterally femoral fractures in a 76-year-old woman.