1.
Biosensors (Basel) ; 13(12)2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38131779

RESUMO

Sleep is a fundamental aspect of daily life, profoundly impacting mental and emotional well-being. Optimal sleep quality is vital for overall health and quality of life, yet many individuals struggle with sleep-related difficulties. In the past, polysomnography (PSG) has served as the gold standard for assessing sleep, but its bulky nature, cost, and the need for expertise has made it cumbersome for widespread use. By recognizing the need for a more accessible and user-friendly approach, wearable home monitoring systems have emerged. EEG technology plays a pivotal role in sleep monitoring, as it captures crucial brain activity data during sleep and serves as a primary indicator of sleep stages and disorders. This review provides an overview of the most recent advancements in wearable sleep monitoring leveraging EEG technology. We summarize the latest EEG devices and systems available in the scientific literature, highlighting their design, form factors, materials, and methods of sleep assessment. By exploring these developments, we aim to offer insights into cutting-edge technologies, shedding light on wearable EEG sensors for advanced at-home sleep monitoring and assessment. This comprehensive review contributes to a broader perspective on enhancing sleep quality and overall health using wearable EEG sensors.


Assuntos
Qualidade de Vida , Dispositivos Eletrônicos Vestíveis , Humanos , Polissonografia/métodos , Sono , Eletroencefalografia , Tecnologia
2.
Biosensors (Basel) ; 13(6)2023 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-37366980

RESUMO

Meticulous monitoring for cardiovascular systems is important for postoperative patients in postanesthesia or the intensive care unit. The continuous auscultation of heart and lung sounds can provide a valuable information for patient safety. Although numerous research projects have proposed the design of continuous cardiopulmonary monitoring devices, they primarily focused on the auscultation of heart and lung sounds and mostly served as screening tools. However, there is a lack of devices that could continuously display and monitor the derived cardiopulmonary parameters. This study presents a novel approach to address this need by proposing a bedside monitoring system that utilizes a lightweight and wearable patch sensor for continuous cardiovascular system monitoring. The heart and lung sounds were collected using a chest stethoscope and microphones, and a developed adaptive noise cancellation algorithm was implemented to remove the background noise corrupted with those sounds. Additionally, a short-distance ECG signal was acquired using electrodes and a high precision analog front end. A high-speed processing microcontroller was used to allow real-time data acquisition, processing, and display. A dedicated tablet-based software was developed to display the acquired signal waveforms and the processed cardiovascular parameters. A significant contribution of this work is the seamless integration of continuous auscultation and ECG signal acquisition, thereby enabling the real-time monitoring of cardiovascular parameters. The wearability and lightweight design of the system were achieved through the use of rigid-flex PCBs, which ensured patient comfort and ease of use. The system provides a high-quality signal acquisition and real-time monitoring of the cardiovascular parameters, thus proving its potential as a health monitoring tool.


Assuntos
Sistema Cardiovascular , Dispositivos Eletrônicos Vestíveis , Humanos , Sons Respiratórios , Monitorização Fisiológica , Eletrocardiografia , Processamento de Sinais Assistido por Computador
3.
Sensors (Basel) ; 21(22)2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34833775

RESUMO

In this study, a fully integrated electroencephalogram/functional near-infrared spectroscopy (EEG/fNIRS) brain monitoring system was designed to fulfill the demand for a miniaturized, light-weight, low-power-consumption, and low-cost brain monitoring system as a potential tool with which to screen for brain diseases. The system is based on the ADS1298IPAG Analog Front-End (AFE) and can simultaneously acquire two-channel EEG signals with a sampling rate of 250 SPS and six-channel fNIRS signals with a sampling rate of 8 SPS. AFE is controlled by Teensy 3.2 and powered by a lithium polymer battery connected to two protection circuits and regulators. The acquired EEG and fNIRS signals are monitored and stored using a Graphical User Interface (GUI). The system was evaluated by implementing several tests to verify its ability to simultaneously acquire EEG and fNIRS signals. The implemented system can acquire EEG and fNIRS signals with a CMRR of -115 dB, power consumption of 0.75 mW/ch, system weight of 70.5 g, probe weight of 3.1 g, and a total cost of USD 130. The results proved that this system can be qualified as a low-cost, light-weight, low-power-consumption, and fully integrated EEG/fNIRS brain monitoring system.


Assuntos
Eletroencefalografia , Espectroscopia de Luz Próxima ao Infravermelho , Encéfalo , Eletrocardiografia , Monitorização Fisiológica
4.
Sensors (Basel) ; 21(20)2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34695968

RESUMO

In surgeries where general anesthesia is required, the auscultation of heart and lung sounds is essential to provide information on the patient's cardiorespiratory system. Heart and lung sounds can be recorded using an esophageal stethoscope; however, there is huge background noise when this device is used in an operating room. In this study, a digital esophageal stethoscope system was designed. A 3D-printed case filled with Polydimethylsiloxane material was designed to hold two electret-type microphones. One of the microphones was placed inside the printed case to collect the heart and lung sound signals coming out from the patient through the esophageal catheter, the other was mounted on the surface of the case to collect the operating room sounds. A developed adaptive noise canceling algorithm was implemented to remove the operating room noise corrupted with the main heart and lung sound signals and the output signal was displayed on software application developed especially for this study. Using the designed case, the noise level of the signal was reduced to some extent, and by adding the adaptive filter, further noise reduction was achieved. The designed system is lightweight and can provide noise-free heart and lung sound signals.


Assuntos
Ruídos Cardíacos , Estetoscópios , Algoritmos , Auscultação , Humanos , Sons Respiratórios , Processamento de Sinais Assistido por Computador