Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Dent ; 2022: 8715777, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35572353

RESUMO

Materials and Methods: A cross-sectional information on demographics, symptomatic disease status, ABO blood group, and oral health-related quality of life (OHRQoL) was collected among 100 patients who were earlier tested positive for COVID-19 reverse transcription-quantitative polymerase chain reaction (RT-qPCR) and were now reporting to the College of Dentistry for routine treatment after recovery. Objective evaluation of olfactory and gustatory disturbances was elicited using the Connecticut Chemosensory Clinical Research Center (CCCRC) test and gustatory function testing. Furthermore, OHRQoL was assessed using Oral Health Impact Profile (OHIP-14). Results: More than half of the patients (62%) had some form of olfactory dysfunction/alteration, and 42% had poor CCCRC scores. About 14% reported ageusia, while 68% reported some form of taste alterations, and 55% reported poor OHRQoL. A statistically significant difference was reported between different ABO blood groups and subjective loss of smell (p < 0.05). The subjective loss of taste, CCCRC score, and dysgeusia were found to be independent of OHIP-14 (p > 0.05), but the taste intensity score was dependent on OHIP 14 (p < 0.05). Moreover, a majority (70.8% and 70.0%) with poor OHIP-14 scores had taste intensity scores of 3 and 4, respectively, while those with moderate (68.4% and 48.6%) OHIP-14 had scored 1 and 2, respectively. Conclusion: Olfactory and gustatory disturbances were found to be a long-term feature in post-COVID-19 patients. The blood group is a predisposing factor for persistent smell alterations in post-COVID-19 patients.

2.
Saudi J Biol Sci ; 28(8): 4683-4690, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34354455

RESUMO

BACKGROUND: Refractive error is an important preventable cause of visual impairment and blindness worldwide. In adult life, reduced vision can potentially affect the academic performance, choice of occupation and socio-economic status. This study aimed to assess the prevalence of refractive errors and related visual impairment among undergraduate male students in Prince Sattam bin Abdulaziz University in Al-Kharj, Saudi Arabia. METHODS: A descriptive cross-sectional study was employed in the current work. After obtaining an informed consent; each eligible student was asked to fill a self-constructed survey and have screened in the college premises for visual acuity and refractive error. Candidates detected with defective vision have been referred for further examination at well-equipped ophthalmology clinic in the University Hospital. RESULTS: A total of 420 undergraduate students, with age ranged from 18 to 30 years, have participated in the current study. About 25.0% of the participants have used spectacles at the time of examination. Positive family history of spectacles use was found in 71.4%. Our study showed that visual acuity in the better eye was low in 34.76% of the participants. Seventy-eight students (18.6%) of the total participants reported defective vision and have fulfilled refractometric examination. Of the examined students 83.3% were found to have refractive errors. Astigmatism, 52.6%, was the most frequently encountered refractive error among the participants; followed by myopia, 26.9%; and hypermetropia 2.6%. CONCLUSION: The current study confirms that refractive error is an important preventable cause of visual impairment. Significant portion of the examined participants were found to have refractive errors recommending further work to improve visual status in undergraduate students.

3.
J Family Med Prim Care ; 8(4): 1422-1426, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31143733

RESUMO

INTRODUCTION: Knowledge of obstetric danger signs among pregnant women is of paramount importance in improving maternal, and fetal health outcomes. This study aims to determine the knowledge of danger signs among pregnant women seeking antenatal care in a teaching hospital. MATERIALS AND METHODS: A cross-sectional study was carried out for two months among pregnant women who visited the antenatal clinic of a teaching hospital. A pre-tested and pre-designed proforma was used. Mean knowledge scores were computed and knowledge was classified into adequate and inadequate. RESULTS: A total of 170 pregnant women fulfilling the inclusion criteria were included. Mean age of the study participants was found to be 26.40 ± 4.14 years. Nearly 67.10% were aware of bleeding per vagina being a danger sign, 50.0% stated excessive vomiting as a danger sign, 23.50% knew that blurring of vision was a danger, while a mere 20.0% reported that convulsions were a danger sign. Overall, adequate knowledge (total knowledge score of 5 and above) was observed in 54.70% of the participants. CONCLUSION: Majority of the study participants had adequate knowledge of danger signs in pregnancy. However, when knowledge about specific individual danger signs were further assessed, a high proportion had very poor knowledge. The mean knowledge scores were found to be low.

4.
Confl Health ; 11: 11, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28572840

RESUMO

BACKGROUND: Refugees and host nationals who accessed antiretroviral therapy (ART) in a remote refugee camp in Kakuma, Kenya (2011-2013) were compared on outcome measures that included viral suppression and adherence to ART. METHODS: This study used a repeated cross-sectional design (Round One and Round Two). All adults (≥18 years) receiving care from the refugee camp clinic and taking antiretroviral therapy (ART) for ≥30 days were invited to participate. Adherence was measured by self-report and monthly pharmacy refills. Whole blood was measured on dried blood spots. HIV-1 RNA was quantified and treatment failures were submitted for drug resistance testing. A remedial intervention was implemented in response to baseline testing. The primary outcome was viral load <5000 copies/mL. The two study rounds took place in 2011-2013. RESULTS: Among eligible adults, 86% (73/85) of refugees and 84% (86/102) of Kenyan host nationals participated in the Round One survey; 60% (44/73) and 58% (50/86) of Round One participants were recruited for Round Two follow-up viral load testing. In Round One, refugees were older than host nationals (median age 36 years, interquartile range, IQR 31, 41 vs 32 years, IQR 27, 38); the groups had similar time on ART (median 147 weeks, IQR 38, 64 vs 139 weeks, IQR 39, 225). There was weak evidence for a difference between proportions of refugees and host nationals who were virologically suppressed (<5000 copies/mL) after 25 weeks on ART (58% vs 43%, p = 0.10) and no difference in the proportions suppressed at Round Two (74% vs 70%, p = 0.66). Mean adherence within each group in Round One was similar. Refugee status was not associated with viral suppression in multivariable analysis (adjusted odds ratio: 1.69, 95% CI 0.79, 3.57; p = 0.17). Among those not suppressed at either timepoint, 69% (9/13) exhibited resistance mutations. CONCLUSIONS: Virologic outcomes among refugees and host nationals were similar but unacceptably low. Slight improvements were observed after a remedial intervention. Virologic monitoring was important for identifying an underperforming ART program in a remote facility that serves refugees alongside host nationals. This work highlights the importance of careful laboratory monitoring of vulnerable populations accessing ART in remote settings.

5.
J Indian Prosthodont Soc ; 11(3): 165-71, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22942576

RESUMO

The aim was to evaluate the design parameters of dental implants shape, diameter and length on stress distribution by finite element analysis (FEA).The objectives of the study was to compare the influence of stress distribution in the implants of screw-vent tapered and parallel design by varying the implant diameter with a standard implant length. Six dental implant models have been simulated three-dimensionally. The influence of diameter and length on stress distribution was evaluated by Group I: for screw-vent tapered design (Zimmer Dental Implant Carlsbad, CA, USA) (1) Dental implant model with diameter 3.7 mm and length 13 mm. (2) Dental implant model with diameter 4.1 mm and length 13 mm. (3) Dental implant model with diameter 4.7 mm and length 13 mm. Group II: for parallel design (Zimmer Dental Implant Carlsbad, CA, USA) (4) Dental implant model with diameter 3.7 mm and length 13 mm. (5) Dental implant model with diameter 4.1 mm and length 13 mm. (6) Dental implant model with diameter 4.7 mm and length 13 mm. The 3-D model of the implant was created in the pro-e wildfire 4.0 software by giving various commands. This model was imported to the ANSYS software through IGES (initial graphic exchange specification) file for further analysis. All six models were loaded with a force of 17.1, 114.6 and 23.4 N in a lingual, an axial and disto-mesial direction respectively, simulating average masticatory force in a natural oblique direction, to analyze the stress distribution on these implants. The increase in implant diameter in Group I and Group II from 3.7 to 4.1 mm and from 4.1 to 4.7 mm with constant 13 mm length for screw-vent tapered and parallel design implant resulted in a reduction in maximum value of Von Mises stress in the bone surrounding the implant was statistically significant at 5% level done by student "t" test. The overall maximum value of Von Mises stress was decreased in parallel design implant diameter of 4.7 mm with constant length of 13 mm when compared to screw-vent tapered design implant samples. The results of the FEA computation depend on many individual factors including material properties, boundary conditions interface definition and also on the overall approach to the model. The results depicted that the tapered shape implant design exhibited higher stress levels in bone than the parallel shaped implant design which seemed to be distributing stresses more evenly. The application of a 3-D model simulation with the non-symmetric loading by the masticatory force on a dental implant resulted in a more satisfactory modeling of "clinical reality" than that achieved with 2-D models used in other studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...