Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1427: 142-60, 2016 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-26687165

RESUMO

A sensitive, accurate and reliable multi-class GC-MS/MS assay protocol for quantification and confirmation of 200 common agricultural pesticides in honey was developed and validated according to EU guidelines. A modified extraction procedure, based on QuEChERS method (quick, easy, cheap, effective, rugged and safe) was employed. Mass spectrophotometric conditions were individually optimized for each analyte to achieve maximum sensitivity and selectivity in MRM mode. The use of at least two reactions for each compound allowed simultaneous identification and quantification in a single run. The pesticides under investigation were separated in less than 31 min using the ultra-inert capillary column (DB-35MS). For all analytes, neat standard calibration curves in conjunction with correction for matrix effect were successfully employed. The detection limits of the assay ranged from 1.00 to 3.00 ng mL(-1) for the studied pesticides. The developed assay was linear over concentration range of 10.00-500.00 ng mL(-1), with correlation coefficient of more than 0.996. At the LOQ, 81% of the studied pesticides were efficiently recovered in the range of 70.00-120.00%, with CV% less than 15.00% while 99.3% compounds had mean percentage recovery of 60.00-140.00%, with CV% less than 21.00% (N=18, over three different days). The proposed assay was successfully applied for the analysis of the studied pesticide residues in one PT sample and 64 commercial honey samples collected over 1 year from different districts around Egypt. Results revealed that only one honey sample out of the 64 analyzed samples was contaminated with tau-Fluvalinate (10.00 µg kg(-1)). This wide scope assay protocol is applicable for monitoring pesticide residues in honey by national regulatory authorities and accredited labs; that should help ensure safety of such widely used product.


Assuntos
Mel/análise , Resíduos de Praguicidas/análise , Calibragem , Cromatografia Gasosa-Espectrometria de Massas/métodos , Limite de Detecção , Espectrometria de Massas em Tandem/métodos
2.
Int J Anal Chem ; 2015: 352610, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25873966

RESUMO

A gas chromatography equipped with mass spectrometer (GCMS) method was developed and validated for determination of 16 polycyclic aromatic hydrocarbons (PAHs) in fish using modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for extraction and solid phase extraction for sample cleanup to remove most of the coextract combined with GCMS for determination of low concentration of selected group of PAHs in homogenized fish samples. PAHs were separated on a GCMS with HP-5ms Ultra Inert GC Column (30 m, 0.25 mm, and 0.25 µm). Mean recovery ranged from 56 to 115%. The extraction efficiency was consistent over the entire range where indeno(1,2,3-cd)pyrene and benzo(g,h,i)perylene showed recovery (65, 69%), respectively, at 2 µg/kg. No significant dispersion of results was observed for the other remaining PAHs and recovery did not differ substantially, and at the lowest and the highest concentrations mean recovery and RSD% showed that most of PAHs were between 70% and 120% with RSD less than 10%. The measurement uncertainty is expressed as expanded uncertainty and in terms of relative standard deviation (at 95% confidence level) is ±12%. This method is suitable for laboratories engaged daily in routine analysis of a large number of samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...