Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
J Basic Clin Physiol Pharmacol ; 34(6): 761-765, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37678295

RESUMO

OBJECTIVES: One of the major risk factors for cardiovascular disease is obesity, particularly abdominal and visceral obesity. Another concern for it is inflammation. Both risk factors are interrelated as obesity is a state of subacute low-grade systemic inflammation. As neck circumference and waist-hip ratio are potential indicators of obesity, we wanted to compare the level of total leukocyte count in subjects with normal and high neck circumference and waist-hip ratio. We also wanted to observe whether there is any correlation between neck circumference and waist-hip ratio with total leukocyte count. METHODS: We selected 62 subjects (30 males, and 32 females) for the study. Both males and females were categorized into groups of normal and high neck circumference and waist-hip ratios. The total leukocyte count was compared among the groups and we correlated neck circumference and waist-hip ratios with total leukocyte count. Statistical analysis was done with SPSS version 23.0. RESULTS: We observed a statistically significant higher value of total leukocyte count in males with a high waist-hip ratio. But there was not a significant increase in TLC in males with high neck circumference. In females, the values were insignificant. On Pearson correlation, there was a negative correlation between neck circumference, waist-hip ratio, and total leukocyte count in both genders which is not significant. CONCLUSIONS: These findings suggest that waist-hip ratio rather than neck circumference might be a proxy measure of a marker of inflammation in males.


Assuntos
Inflamação , Obesidade , Humanos , Masculino , Feminino , Adolescente , Relação Cintura-Quadril , Índice de Massa Corporal , Obesidade/complicações , Fatores de Risco , Contagem de Leucócitos , Inflamação/complicações
2.
Water Sci Technol ; 79(5): 842-849, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31025962

RESUMO

Selenium, a ubiquitous non-metal in nature, is potentially toxic to natural ecosystems due to its bioaccumulation potential. Due to increased monitoring and enforcement of selenium regulations, the need to be able to measure and treat selenium efficiently has taken on an increased importance. The principal aqueous forms of inorganic selenium are selenite (Se(IV)) and selenate (Se(VI)). Selenate, due to its high mobility and lack of affinity to conventional adsorbents, is typically much more difficult to treat and remove. To address both measurement and removal, an analytical method is reported for quantification of selenium in wastewater (WW) using UV-Vis spectrophotometer followed by removal studies using advanced oxidation processes (AOPs). Malachite green and azure blue were selected for colorimetric analysis using UV-Vis. Malachite green indicator showed the best results for analysis. The reported UV-Vis method was applied to establish the effect of AOPs on selenium removal. It was noted that all of the AOP treated samples showed removal of selenium and it was established that the UV-Vis method has a lower limit of detection at 2 mg/L. Further, through this study, it was found that the chemical cavitation yield and selenium removal efficiency peaked at low frequency ultrasound of 40 kHz.


Assuntos
Selênio/análise , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/química , Poluentes Químicos da Água/análise , Oxirredução , Ácido Selênico , Ácido Selenioso , Compostos de Selênio
3.
Nanoscale ; 10(29): 14321-14330, 2018 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-30020299

RESUMO

We show that the terahertz photoconductivity of monolayer graphene following 800 nm femtosecond optical pump excitation can be tuned by different levels of hydrogenation (graphane) and provide a quantitative understanding of the unique spectral dependence of photoconductivity. The real part of terahertz photoconductivity (ΔσRe(ω)), which is negative in doped pristine graphene, becomes positive after hydrogenation. Frequency and electronic temperature Te dependent conductivity σ(ω, Te) is calculated using the Boltzmann transport equation taking into account the energy dependence of different scattering rates of the hot carriers. It is shown that the carrier scattering rate dominated by disorder-induced short-range scattering, though sufficient for pristine graphene, is not able to explain the observed complex Δσ(ω) for graphane. Our results are explained by considering the system to be heterogeneous after hydrogenation where conductivity is a weighted sum of conductivities of two parts: one dominated by Coulomb scattering coming from trapped charge impurities in the underlying substrate and the other dominated by short-range scattering coming from disorder, surface defects, dislocations and ripples in graphene flakes. A finite band gap opening due to hydrogenation is shown to be important in determining Δσ(ω).

4.
ACS Nano ; 12(2): 1785-1792, 2018 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-29309138

RESUMO

Photoinduced terahertz conductivity Δσ(ω) of Bernal stacked bilayer graphene (BLG) with different dopings is measured by time-resolved optical pump terahertz probe spectroscopy. The real part of photoconductivity Δσ(ω) (ΔσRe(ω)) is positive throughout the spectral range 0.5-2.5 THz in low-doped BLG. This is in sharp contrast to Δσ(ω) for high-doped bilayer graphene where ΔσRe(ω) is negative at low frequency and positive on the high frequency side. We use Boltzmann transport theory to understand quantitatively the frequency dependence of Δσ(ω), demanding the energy dependence of different scattering rates such as short-range impurity scattering, Coulomb scattering, carrier-acoustic phonon scattering, and substrate surface optical phonon scattering. We find that the short-range disorder scattering dominates over other processes. The calculated photoconductivity captures very well the experimental conductivity spectra as a function of lattice temperature varying from 300 to 4 K, without any empirical fitting procedures adopted so far in the literature. This helps us to understand the intraband conductivity of photoexcited hot carriers in 2D materials.

5.
World J Clin Cases ; 3(10): 864-71, 2015 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-26488021

RESUMO

Laparoscopic surgery (LS), also termed minimal access surgery, has brought a paradigm shift in the approach to modern surgical care. Early postoperative recovery, less pain, improved aesthesis and early return to work have led to its popularity both amongst surgeons and patients. Its application has progressed from cholecystectomies and appendectomies to various other fields including gastrointestinal surgery, urology, gynecology and oncosurgery. However, LS has its own package of complications. Port site infection (PSI), although infrequent, is one of the bothersome complications which undermine the benefits of minimal invasive surgery. Not only does it add to the morbidity of the patient but also spoils the reputation of the surgeon. Despite the advances in the field of antimicrobial agents, sterilization techniques, surgical techniques, operating room ventilation, PSIs still prevail. The emergence of rapid growing atypical mycobacteria with multidrug resistance, which are the causative organism in most of the cases, has further compounded the problem. PSIs are preventable if appropriate measures are taken preoperatively, intraoperatively and postoperatively. PSIs can often be treated non-surgically, with early identification and appropriate management. Macrolides, quinolones and aminoglycosides antibiotics do show promising activity against the atypical mycobacteria. This review article highlights the clinical burden, presentations and management of PSIs in LS as shared by various authors in the literature. We have given emphasis to atypical mycobacteria, which are emerging as a common etiological agent for PSIs in LS. Although the existing literature lacks consensus regarding PSI management, the complication can be best avoided by strictly abiding by the commandments of sterilization techniques of the laparoscopic instruments with appropriate sterilizing agent.

6.
Nanoscale ; 7(38): 15806-13, 2015 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-26355471

RESUMO

We report the photoresponse of stacked graphene layers towards infrared radiation. Graphene is stacked in two configurations, namely, crossed and parallel layers. Raman analysis demonstrated a strong interaction among the stacked graphene layers. Graphene in the crossed configuration exhibited the presence of both negative and positive conductivities; however, other configurations of graphene exhibited positive conductivity only. The presence of negative photoconductivity is proposed to be due to oxygen or oxygen-related functional group absorbents that are trapped in between two monolayers of graphene and act as scattering centers for free carriers. An interesting trend is reported in differential conductivity when stacked layers are compared with multilayers and parallel-stacked graphene layers.

7.
ACS Appl Mater Interfaces ; 6(19): 16763-8, 2014 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-25208466

RESUMO

We report the photoresponse of a hydrogenated graphene (H-graphene)-based infrared (IR) photodetector that is 4 times higher than that of pristine graphene. An enhanced photoresponse in H-graphene is attributed to the longer photoinduced carrier lifetime and hence a higher internal quantum efficiency of the device. Moreover, a variation in the angle of incidence of IR radiation demonstrated a nonlinear photoresponse of the detector, which can be attributed to the photon drag effect. However, a linear dependence of the photoresponse is revealed with different incident powers for a given angle of IR incidence. This study presents H-graphene as a tunable photodetector for advanced photoelectronic devices with higher responsivity. In addition, in situ tunability of the graphene bandgap enables achieving a cost-effective technique for developing photodetectors without involving any external treatments.

8.
Nanotechnology ; 25(33): 335710, 2014 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-25073488

RESUMO

The photoresponse of the graphene photodetector elucidated strong dependence on several optical parameters, such as the angle of incidence and the incident power of infrared exposure at room temperature. The sinusoidal dependence of the photoresponse on incidence angle, which had not been realized before, has now been revealed. The combined effect of the photo excited charge carrier and the photon drag effect explain this nonlinear optical absorption in graphene at lower incident power. The nonlinear dependence of the charge carrier generation on the incident power revealed that this process contributed to the nonlinear photoresponse. However, a deviation is observed at a higher incident power due to the induction of thermal effects in the graphene lattice. This work demonstrates the tunability of the graphene photodetector under a systematic variation that involves both parameters.

9.
ACS Nano ; 5(3): 1724-30, 2011 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-21344873

RESUMO

We report the healing of electrically broken multiwalled carbon nanotubes (MWNTs) using very low energy electrons (3-10 keV) in scanning electron microscopy (SEM). Current-induced breakdown caused by Joule heating has been achieved by applying suitably high voltages. The broken tubes were examined and exposed to electrons of 3-10 keV in situ in SEM with careful maneuvering of the electron beam at the broken site, which results in the mechanical joining of the tube. Electrical recovery of the same tube has been confirmed by performing the current-voltage measurements after joining. This easy approach is directly applicable for the repairing of carbon nanotubes incorporated in ready devices, such as in on-chip horizontal interconnects or on-tip probing applications, such as in scanning tunneling microscopy.


Assuntos
Cristalização/métodos , Microscopia Eletrônica de Varredura/métodos , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Nanotecnologia/métodos , Elétrons , Teste de Materiais , Conformação Molecular/efeitos da radiação , Nanoestruturas/efeitos da radiação , Tamanho da Partícula , Doses de Radiação
10.
ACS Nano ; 3(9): 2617-22, 2009 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-19719150

RESUMO

Nanostructures based on multiwalled carbon nanotubes (MWNTs) are fabricated using plasma of the mixture of hydrogen and nitrogen gases. The plasma-sharpened tips of nanotubes contain only a few tubes at the apex of the structure and lead to the dramatic enhancement in the emission current density by a factor >10(6) with the onset field as low as 0.16 V/microm. We propose that the nature of the tunneling barrier changes significantly for a nanosize tip at very high local electric field and may lead to the saturation in the emission current density.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...