Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 14: 127-132, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32021077

RESUMO

PURPOSE: The purpose of this study is to compare anatomical and visual outcomes after using silicone oil (SO) or C3F8 gas as tamponades after pars plana vitrectomy (PPV) for retinal detachment (RD) associated with giant retinal tears (GRTs). METHODS: A retrospective chart review was conducted for cases that underwent PPV for GRT-associated RD. We excluded eyes that had prior vitreoretinal surgery, a history of ocular trauma or worse than grade B proliferative vitreoretinopathy (PVR). Baseline demographic and ocular characteristics, surgical details and postoperative anatomical and visual outcomes were recorded and statistically analyzed. RESULTS: We included 88 eyes; 48 eyes had C3F8 gas and 40 eyes had SO as a tamponading agent. Mean age was 39 years. All eyes underwent 23G PPV with no adjuvant scleral buckling and phacovitrectomy was performed for all phakic eyes. Final retinal reattachment was achieved in 86 eyes (97.7%). One eye from each group had recurrent RD. Postoperative vision was significantly better in the gas group (p= 0.008). Prolonged increase of IOP developed in 6 eyes in the SO group and 5 eyes in the gas group. Prolonged uveitis developed in 4 eyes in the gas group and 6 eyes in the oil group (P= 0.04). Epiretinal membranes (ERM) developed in 10 eyes in the gas group and 9 eyes in the oil group. We found no significant difference between both groups regarding postoperative glaucoma or ERM formation. CONCLUSION: Both agents achieved similar favorable anatomical outcomes in a series of eyes with fresh GRT-associated RD and low-grade PVR, with better visual outcome and less frequent uveitis associated with the use of gas tamponade.

2.
J Ophthalmol ; 2016: 4060467, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27672446

RESUMO

Purpose. To evaluate the anterior segment, the anatomical position of the implantable collamer lenses (ICL), and its relationship to adjacent ocular structures using Ultrasound Biomicroscopy (UBM). Methods. In a prospective study, 142 myopic eyes of 93 patients implanted with Visian ICL were subjected to UBM examination between March 2010 and January 2015. The relative position of ICL to the adjacent structure and the overall iris configuration were evaluated. The machine calibers were used to measure the minimum central distance between the ICL and anterior lens capsule (vault) and the vertical central distance between the corneal endothelium and the ICL (E-ICL). Results. The mean ICL vault was 376 ± 105 µm. The mean E-ICL was 2826 ± 331 µm. Contact between ICL and the posterior epithelium of the iris was present in all eyes. The overall iris configuration was flat in 89 eyes. Central anterior convexity was present in 41 eyes and mild peripheral iris bombe in 12 eyes. The haptics could be imaged in the ciliary sulcus in 112 eyes and at least one haptic resting on the lens periphery and zonules in 30 eyes. Conclusion. UBM can provide valuable anatomical information that allows detailed postoperative in vivo assessment of ICL.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...