Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Coron Artery Dis ; 33(2): 128-136, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34010184

RESUMO

The great saphenous vein (GSV) graft remains a frequently used conduit for coronary artery bypass graft (CABG) surgery. The optimal technique for GSV harvesting has been the subject of on-going controversy. We therefore sought to conduct a systematic review and meta-analysis of all available GSV harvesting techniques in CABG. A systematic search of 12 electronic databases was performed to identify all randomized controlled trials (RCTs) of any GSV harvesting technique, including conventional vein harvesting (CVH), no-touch, standard bridging technique (SBT) and endoscopic vein harvesting (EVH) techniques. We investigated safety and long-term efficacy outcomes. All outcomes were analyzed using the frequentist network meta-analysis. A total of 6480 patients from 34 RCTs were included. For safety outcomes, EVH reduced 91% and 77% risk of wound infection compared to no-touch and CVH, respectively. EVH and SBT also significantly reduced the risk of sensibility disorder and postoperative pain. The techniques were not significantly different regarding long-term efficacy outcomes, including mortality, myocardial infarction and graft patency. For GSV harvesting for CABG, EVH techniques are the most favorable, but in case of using an open technique, no-touch is more recommended than CVH. More effective and safer procedures should be investigated for GSV harvesting in CABG.


Assuntos
Ponte de Artéria Coronária/métodos , Veia Safena/fisiopatologia , Grau de Desobstrução Vascular/fisiologia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Veia Safena/fisiologia
2.
J Cardiovasc Transl Res ; 11(6): 483-494, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30315504

RESUMO

Saphenous vein (SV) is a common graft being used in coronary artery bypass grafting (CABG). Conventional (CON), intermediate (I), and no-touch (NT) are the most common harvesting techniques of SV for CABG. The aim of this study is to systematically review the NT versus CON and I techniques in harvesting SV for CABG. Twelve databases were searched for randomized controlled trials comparing the CON, I, and NT techniques in harvesting SV for CABG. Twelve reports of six RCTs were included. Our meta-analysis showed that with NT technique, patency rate was significantly higher when compared to I technique up to 18-month follow-up duration. In contrast, this significant difference was not maintained in terms of minor complications of leg wounds with both techniques. The NT has significantly higher patency rate compared to I vein harvesting technique. However, more RCTs are warranted to confirm these results.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Veia Safena/transplante , Coleta de Tecidos e Órgãos/métodos , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Fatores de Risco , Veia Safena/fisiopatologia , Fatores de Tempo , Coleta de Tecidos e Órgãos/efeitos adversos , Coleta de Tecidos e Órgãos/mortalidade , Resultado do Tratamento , Grau de Desobstrução Vascular
3.
Int J Cardiol ; 244: 67-76, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28647440

RESUMO

BACKGROUND: Our study aimed to compare three different percutaneous coronary intervention (PCI) approaches: culprit-only (COR) and complete (CR) revascularization - categorizing into immediate (ICR) or staged (SCR). METHODS: We searched 13 databases for randomized controlled trials. Articles were included if they compared at least two strategies. To have more studies in each analysis, an adjusted analysis was performed using person-years to incorporate follow-up durations and obtain pooled rate ratios (RR), with their corresponding 95% confidence interval. RESULTS: Thirteen trials were included with a population of 2830 patients. COR significantly increased major adverse cardiac event (MACE) (adjusted RR 1.67, 95% CI: 1.27-2.19) and repeat revascularization (2.12, 1.67-2.69), which was driven by repeat PCI, without any difference in all-cause mortality and myocardial infarction (MI) compared to CR. When categorizing CR into SCR and ICR, the trend repeated with COR increased MACE (1.99, 1.53-2.6 for ICR), cardiovascular mortality (2.06, 1.07-3.96 for ICR), MI for ICR (1.72, 1.04-2.86), repeat revascularization and repeat PCI for both ICR and SCR. Non-cardiovascular mortality, stroke, nephropathy, re-hospitalization, stent thrombosis and bleeding were similar among all approaches. CONCLUSIONS: In MVD-STEMI patients, CR is better than COR in terms of MACE, cardiovascular mortality, repeat revascularization with no difference in safety outcomes. There was a trend towards to a reduction of cardiovascular mortality and MI in ICR compared to SCR when each matched with COR; even though there is no statistically significant difference between ICR and SCR when compared together.


Assuntos
Doença da Artéria Coronariana/terapia , Revascularização Miocárdica/normas , Intervenção Coronária Percutânea/normas , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Humanos , Revascularização Miocárdica/métodos , Intervenção Coronária Percutânea/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...