1.
Turk J Ophthalmol ; 47(2): 85-88, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28405482

RESUMO

OBJECTIVES: To investigate the relationship between serum carbonic anhydrase I-II (CA-I and II) autoantibody levels and diabetic retinopathy (DRP) in cases with type 1 diabetes. MATERIALS AND METHODS: A total of 37 type-1 diabetic patients, 17 with DRP (group 1) and 20 without (group 2), and 38 healthy control subjects (group 3) were included. CA-I and CA-II autoantibody levels were measured in serum samples obtained from each of the three groups and compared statistically. Additionally, the correlation between CA-I and CA-II autoantibody levels and the presence of diabetic macular edema was examined. RESULTS: Mean measured CA-I autoantibody levels were 0.145±0.072, 0.117±0.047, and 0.138±0.061 ABSU in group 1, group 2, and group 3, respectively (p=0.327). The average CA-II autoantibody levels achieved in the same groups were 0.253±0.174, 0.155±0.137, and 0.131±0.085 ABSU, respectively (p=0.005). No significant difference was obtained between the subgroups of group 1, with macular edema (n=8) and without (n=9), in terms of both CA-I and CA-II autoantibody levels (p=0.501, p=0.178, respectively). CONCLUSION: A significant correlation was observed between the development of DRP and serum CA-II autoantibody levels in type 1 diabetic cases. However, there was no correlation between the autoantibody levels and the presence of diabetic macular edema in cases with DRP.

3.
J Ophthalmol ; 2014: 739652, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25136453

RESUMO

Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ). Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC). Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2) and reproducibility (ICC, 0.916-0.999) were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2) and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all). Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.

4.
Ocul Immunol Inflamm ; 22(6): 434-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24988331

RESUMO

UNLABELLED: Abstract Purpose: To investigate posterior segment (PS) findings in the eye in patients with ankylosing spondylitis (AS). METHODS: Eighty-four patients with AS and 63 healthy controls were enrolled. PS evaluations were performed using optical coherence tomography (OCT). Foveal thickness, peripapillary retinal nerve fiber layer thickness, macular volume, ganglion cell complex, and choroidal thickness (CT) values were compared between the groups. RESULTS: Mean CT was higher in patients with AS (326.5 ± 71.5 µm) than in the healthy controls (286.2 ± 59.5 µm) (p = 0.001). There was no significant difference between patients with AS and the healthy control group in terms of other OCT parameters. There was also no significant correlation between CT, AS activity index, and disease duration. CONCLUSIONS: This is the first study to evaluate effects of AS on CT. CT was high in patients with AS compared to healthy controls.


Assuntos
Corioide/patologia , Espondilite Anquilosante/patologia , Tomografia de Coerência Óptica/métodos , Adulto , Estudos Transversais , Feminino , Humanos , Hipertrofia/etiologia , Hipertrofia/patologia , Masculino , Espondilite Anquilosante/complicações
5.
Int J Ophthalmol ; 6(4): 537-41, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23991393

RESUMO

AIM: To evaluate the possible effects of phacoemulsification cataract surgery on ocular hemodynamics. METHODS: In this prospective study, intraocular pressure (IOP), pulsatile ocular blood flow (POBF), and ocular pulse amplitude (OPA) were measured pre-operatively (baseline) and at 1 week and 3 weeks postoperation in 52 eyes of 26 patients (mean age 63.15±10.25 years) scheduled for unilateral phacoemulsification cataract surgery with intraocular lens implantation. In all of the eyes, a blood flow analyzer (Paradigm DICON; Paradigm Medical Industries Inc.; USA) was used to obtain measurements of IOP, POBF, and OPA. The data obtained from operated eyes were compared statistically to untreated fellow phakic eyes of the patients. RESULTS: For operated eyes, the mean baseline IOP, POBF, and OPA values were 15.9±4.64mmHg, 17.41±4.84µL/s, and 2.91±1.12mmHg, respectively. The IOP, POBF, and OPA values were 17.19±4.34mmHg, 17.56±6.46µL/s, and 3.12±1.1mmHg, respectively, in the nonoperated control eyes. Statistically significant differences from baseline measurements were not observed 1 week and 3 weeks postoperation for the operated or nonoperated eyes. There were also no statistically significant differences in any measurements between the operated and nonoperated eyes in all the examination periods (P>0.05 for all). CONCLUSION: Uncomplicated phacoemulsification surgery does not affect ocular hemodynamics in normotensive eyes with cataracts.