1.
Nanoscale ; 16(26): 12559-12566, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38888625

RESUMO

DNA-stabilized silver nanoclusters (DNA-AgNCs) are biocompatible emitters formed by silver atoms and cations encapsulated in DNA oligomers. Here, we present an analytical approach to calculate the molar absorption coefficient (ε) of these systems, which consists of combining UV-Vis spectroscopy, electrospray ionization-mass spectrometry (ESI-MS), and inductively coupled plasma-optical emission spectrometry (ICP-OES). ESI-MS enables the determination of the number of silvers bound to the DNA strands, whereas ICP-OES allows measurement of the total amount of silver in solution. The data is used to calculate the concentration of DNA-AgNCs and together with UV-Vis absorbance, allows for the calculation of ε. We compare the obtained ε with the experimental values previously determined through fluorescence correlation spectroscopy (FCS) and theoretical estimates based on the ε of the DNA itself. Finally, the experimental radiative decay rates (kf) and ε values are evaluated and compared to those typically found for organic fluorophores, highlighting the molecular-like nature of the DNA-AgNC emission.


Assuntos
DNA , Nanopartículas Metálicas , Prata , Prata/química , DNA/química , Nanopartículas Metálicas/química , Espectrofotometria Ultravioleta , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Fluorescência
2.
Angew Chem Int Ed Engl ; 62(39): e202309760, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37578902

RESUMO

DNA-stabilized silver nanoclusters (DNA-AgNCs) are easily tunable emitters with intriguing photophysical properties. Here, a DNA-AgNC with dual emission in the red and near-infrared (NIR) regions is presented. Mass spectrometry data showed that two DNA strands stabilize 18 silver atoms with a nanocluster charge of 12+. Besides determining the composition and charge of DNA2 [Ag18 ]12+ , steady-state and time-resolved methods were applied to characterize the picosecond red fluorescence and the relatively intense microsecond-lived NIR luminescence. During this process, the luminescence-to-fluorescence ratio was found to be excitation-intensity-dependent. This peculiar feature is very rare for molecular emitters and allows the use of DNA2 [Ag18 ]12+ as a nanoscale excitation intensity probe. For this purpose, calibration curves were constructed using three different approaches based either on steady-state or time-resolved emission measurements. The results showed that processes like thermally activated delayed fluorescence (TADF) or photon upconversion through triplet-triplet annihilation (TTA) could be excluded for DNA2 [Ag18 ]12+ . We, therefore, speculate that the ratiometric excitation intensity response could be the result of optically activated delayed fluorescence.


Assuntos
Nanoestruturas , Prata , Prata/química , Nanoestruturas/química , DNA/química , Espectrometria de Fluorescência , Fótons
3.
Front Chem ; 10: 868532, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35692684

RESUMO

The expanding and dynamic market of new psychoactive substances (NPSs) poses challenges for laboratories worldwide. The retrospective data analysis (RDA) of previously analyzed samples for new targets can be used to investigate analytes missed in the first data analysis. However, RDA has historically been unsuitable for routine evaluation because reprocessing and reevaluating large numbers of forensic samples are highly work- and time-consuming. In this project, we developed an efficient and scalable retrospective data analysis workflow that can easily be tailored and optimized for groups of NPSs. The objectives of the study were to establish a retrospective data analysis workflow for benzodiazepines in whole blood samples and apply it on previously analyzed driving-under-the-influence-of-drugs (DUID) cases. The RDA workflow was based on a training set of hits in ultrahigh-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (UHPLC-QTOF-MS) data files, corresponding to common benzodiazepines that also had been analyzed with a complementary UHPLC-tandem mass spectrometry (MS/MS) method. Quantitative results in the training set were used as the true condition to evaluate whether a hit in the UHPLC-QTOF-MS data file was true or false positive. The training set was used to evaluate and set filters. The RDA was used to extract information from 47 DBZDs in 13,514 UHPLC-QTOF-MS data files from DUID cases analyzed from 2014 to 2020, with filters on the retention time window, count level, and mass error. Sixteen designer and uncommon benzodiazepines (DBZDs) were detected, where 47 identifications had been confirmed by using complementary methods when the case was open (confirmed positive finding), and 43 targets were not reported when the case was open (tentative positive finding). The most common tentative and confirmed findings were etizolam (n = 26), phenazepam (n = 13), lorazepam (n = 9), and flualprazolam (n = 8). This method efficiently found DBZDs in previously acquired UHPLC-QTOF-MS data files, with only nine false-positive hits. When the standard of an emerging DBZD becomes available, all previously acquired DUID data files can be screened in less than 1 min. Being able to perform a fast and accurate retrospective data analysis across previously acquired data files is a major technological advancement in monitoring NPS abuse.

4.
Drug Test Anal ; 14(9): 1645-1651, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35687099

RESUMO

Synthetic cannabinoids (SCs) remain the largest class of new psychoactive substances (NPS), and while the number of NPS that are reported to the European Monitoring Centre for Drugs and Drug Addiction (EMCDDA) for the first time each year declines, the number of newly reported SCs still exceeds other NPS classes. This decline can be seen as a result of legislative changes by different jurisdictions which have sometimes transitioned to a more generalized approach when controlling substances by defining common structural scaffolds rather than explicit structures. While the consequences of such legislative changes have been expected over the years, the introduction of so-called "class-wide" bans puts further pressure on clandestine laboratories to synthesize compounds which are out of the scope of the legislation, and thus, these compounds are initially harder to detect and/or identify in the absence of analytical data. Recently, a SC with an indole-3-acetamide core-linker scaffold, AD-18 (i.e., ADB-FUBIATA or ADB-FUBIACA), was reported for the first time in China in 2021. Here, an additional cannabinoid with the indole-3-acetamide scaffold, N-cyclohexyl-2-(1-pentyl-1H-indol-3-yl)acetamide (CH-PIACA), is reported which was identified for the first time in a seized material in Denmark. Structural characterization was performed using gas chromatography-mass spectrometry (GC-MS), liquid chromatography-high-resolution mass spectrometry (LC-HRMS), and nuclear magnetic resonance (NMR) spectroscopy.


Assuntos
Canabinoides , Drogas Ilícitas , Transtornos Relacionados ao Uso de Substâncias , Canabinoides/análise , Cromatografia Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Drogas Ilícitas/análise , Espectrometria de Massas/métodos
5.
Drug Test Anal ; 14(4): 747-756, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34984831

RESUMO

Due to the large number of basic therapeutic and illicit drugs, systematic toxicological analysis has widely been performed with liquid chromatography coupled to mass spectrometry using positive electrospray ionization. However, there exist a smaller number of drugs, typically acidic drugs, which require the use of negative electrospray ionization either via a separate analysis or polarity switching. Here, targets relating to salicylic acid and ibuprofen in positive electrospray ionization were determined through a metabolomics-driven retrospective investigation of forensic casework. Samples were previously screened using liquid chromatography coupled with high-resolution mass spectrometry with quantification of target analytes performed using liquid chromatography with tandem mass spectrometry. Of the 1,717 whole-blood samples submitted between 2014 and 2019, 48 were positive for salicylic acid (1.1-1,400 mg/kg) and 78 for ibuprofen (1-46 mg/kg). Based on the retrospective analysis, 19 and 90 targets were identified for salicylic acid and ibuprofen, respectively. For targets of salicylic acid, the protonated adduct of salicyluric acid ([M + H]+ , m/z 196.0605) was present in 89.6% (n = 32) of the salicylic acid positive cases, while the [M + HCOOH + CH3 CN + Ca - H]+ adduct (m/z 264.0179) of salicylic acid was present in all positive samples with concentrations above 66 mg/kg salicylic acid. Similarly, the [M + 2Na - H]+ adduct (m/z 251.1018) of ibuprofen was present in 98.7% (n = 77) of positive cases and was present in all samples with concentrations above 3 mg/kg ibuprofen.


Assuntos
Ibuprofeno , Espectrometria de Massas por Ionização por Electrospray , Metabolômica , Estudos Retrospectivos , Ácido Salicílico , Espectrometria de Massas por Ionização por Electrospray/métodos
6.
Drug Test Anal ; 14(3): 462-473, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34265168

RESUMO

Illicit drug profiling performed by forensic laboratories assists law enforcement agencies through providing information about chemical and/or physical characteristics of seized specimens. In this article, a model was developed for the comparison of seized cocaine based on retrospective analysis of data generated from ultrahigh performance liquid chromatography with time-of-flight mass spectrometry (UHPLC-TOF-MS) comprehensive drug screening. A nontargeted approach to discover target compounds was employed, which generated 53 potential markers using data from cocaine positive samples. Twelve marker compounds were selected for the development of the final profiling model. The selection included a mixture of commonly used cocaine profiling targets and other cocaine-related compounds. Combinations of pretreatments and comparison metrics were assessed using receiver operating characteristic curves to determine the combination with the best discrimination between linked and unlinked populations. Using data from 382 linked and 34,519 unlinked distances, a classification model was developed using a combination of the standardization and normalization transformations with Canberra distance, resulting in a linked cut-off with a 0.5% false positive rate. The present study demonstrates the applicability of retrospectively developing a cocaine profiling model using data generated from UHPLC-TOF-MS nontargeted drug screening without pre-existing information about cocaine impurities. The developed workflow was not specific to cocaine and thus could potentially be applied to any seized drug in which there are both sufficient data and impurities present.


Assuntos
Cocaína , Drogas Ilícitas , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Cocaína/análise , Drogas Ilícitas/análise , Espectrometria de Massas , Estudos Retrospectivos
7.
Anal Chim Acta ; 1184: 339035, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34625246

RESUMO

Database-driven suspect screening has proven to be a useful tool to detect new psychoactive substances (NPS) outside the scope of targeted screening; however, the lack of retention times specific to a liquid chromatography (LC) system can result in a large number of false positives. A singular stream-lined, quantitative structure-retention relationship (QSRR)-based retention time prediction model integrating multiple LC systems with different elution conditions is presented using retention time data (n = 1281) from the online crowd-sourced database, HighResNPS. Modelling was performed using an artificial neural network (ANN), specifically a multi-layer perceptron (MLP), using four molecular descriptors and one-hot encoding of categorical labels. Evaluation of test set predictions (n = 193) yielded coefficient of determination (R2) and mean absolute error (MAE) values of 0.942 and 0.583 min, respectively. The model successfully differentiated between LC systems, predicting 54%, 81% and 97% of the test set within ±0.5, ±1 and ±2 min, respectively. Additionally, retention times for an analyte not previously observed by the model were predicted within ±1 min for each LC system. The developed model can be used to predict retention times for all analytes on HighResNPS for each participating laboratory's LC system to further support suspect screening.


Assuntos
Redes Neurais de Computação , Cromatografia Líquida , Bases de Dados Factuais
9.
J Anal Toxicol ; 43(7): 520-527, 2019 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-31095696

RESUMO

The number of new psychoactive substances (NPS) is constantly increasing. However, although the number might be large, most NPS have a low prevalence of use, so keeping screening libraries updated with the relevant analytical targets becomes a challenge. One way to ensure sufficient screening coverage is to use shared high resolution-mass spectrometry (HR-MS) databases, such as HighResNPS.com: a free, online, spreadsheet-format, crowd-sourced HR-MS database for NPS screening. The aims of this study were (i) to present the database to the scientific community and (ii) to verify that the HighResNPS database can be utilized in suspect screening workflows for LC-HR-MS instruments and software from four different instrument vendors. A sample was spiked with 10 NPS, and participating laboratories then analyzed the sample with their respective HR-MS vendor platforms and the HighResNPS database. The HighResNPS data were obtained via a spreadsheet converted to fit the import specifications of the different vendor platforms. Suspect screening was performed using LC-HR-MS vendor platforms from Thermo Fisher, Waters, Bruker and Agilent. All 10 NPS were identified in at least three workflows used for the four different vendor platforms. Multiple users have submitted data to HighResNPS for the same NPS, which resulted in multiple true-positive identifications for these NPS. Suspect screening with LC-HR-MS can be based on diagnostic fragment ions reported by users of different vendor platforms and can support NPS identification in biological samples and/or seizure analyses when no reference standard is available in-house. The present work clearly demonstrates that HighResNPS data is compatible with instruments and screening software from at least four different vendor platforms. The database can thus serve as a useful add-on in LC-HR-MS screening workflows.


Assuntos
Crowdsourcing , Bases de Dados Factuais , Drogas Ilícitas/análise , Espectrometria de Massas/métodos , Psicotrópicos/análise , Detecção do Abuso de Substâncias/métodos , Humanos , Fluxo de Trabalho
10.
Drug Test Anal ; 11(8): 1258-1263, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30993867

RESUMO

Comprehensive drug-screening performed by liquid chromatography-high resolution mass spectrometry (LC-HRMS) enables identification of hundreds to thousands of drug compounds in a single analysis. Forensic drug screening is generally performed with positive electrospray ionization (ESI+ ), targeting basic drugs; however, a few toxicologically important drugs such as barbiturates, may require analysis by negative ESI. In this work, screening targets for barbiturates were determined using our LC-HRMS screening with ESI+ . For several years, our forensic whole blood samples have been analyzed using the LC-HRMS-ESI+ screening in parallel with a multi-target LC-MS/MS-ESI- method. From 2014 to 2018, 23 samples were positive for phenobarbital (0.5-81 mg/kg). Retrospective data analysis of 4816 blood samples (15 positive) revealed several potential screening targets for phenobarbital. The targets were tentatively identified by exact mass and isotopic pattern as uncommon adducts of phenobarbital and as a decomposition product of phenobarbital N-glucoside (C17 H24 N2 O7 ). Analysis of a test set containing eight positive (0.5-65 mg/kg phenobarbital) and 31 negative samples supported the use of the observed target m/z 323.0614 at 5.14 minutes, corresponding to the [M + HCOONa+Na]+ adduct of phenobarbital. The [M + HCOONa+Na]+ adduct was confirmed as a screening target for common barbiturates, by analysis of barbiturate reference standards in ESI+ /ESI- . The [M + HCOONa+Na]+ adduct allowed retrospective analysis with 91% sensitivity (n = 23) and 100% specificity (n = 4855) for phenobarbital in our existing LC-HRMS-ESI+ screening. The two negative results were the two whole-blood samples with the lowest phenobarbital concentration (<1.8 mg/kg). Thus, a specialized screening is not necessary and use of this adduct likely enables screening for other barbiturates.


Assuntos
Barbitúricos/sangue , Hipnóticos e Sedativos/sangue , Fenobarbital/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Cromatografia Líquida de Alta Pressão/métodos , Medicina Legal/métodos , Humanos , Limite de Detecção , Espectrometria de Massas em Tandem/métodos
11.
Drug Test Anal ; 11(5): 730-738, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30426701

RESUMO

Liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) is an important analytical tool in the systematic toxicological analysis performed in forensic toxicology. However, some important compounds, such as the antiepileptic drug valproate (valproic acid; VPA), cannot be directly detected with positive electrospray ionization (ESI+ ) due to poor ionization. Here we demonstrate an omics-based retrospective analysis for the identification of indirect screening targets for VPA in whole blood with LC-ESI+ -HRMS. Analysis was performed utilizing data acquired across four years from LC-ESI+ -HRMS, with VPA results from a quantitative LC-MS/MS method. The combined data with VPA results were split into an exploration set (n = 68; 28% positive) and a test set (n = 37; 32% positive). Eight indirect targets for VPA were identified in the exploration set. The evaluation of these targets was confirmed with retrospective target analysis of the test set. Using a combination of two out of the eight indirect targets, we attained a sensitivity of 92% (n = 12; VPA concentration range: 4.4-29.7 mg/kg) and 100% specificity (n = 25) for VPA with LC-ESI+ -HRMS. VPA screening targets were identified with retrospective data analysis and could be appended to the existing screening procedure. A sensitive and specific screening with LC-ESI+ -HRMS was achieved with targets corresponding to the sodium adducts of C7 H14 O3 and C8 H14 O3 . Three chromatographic resolved isomer peaks were observed for the latter, and the consistently most intense peak was tentatively identified as 3-hydroxy-4-en-VPA.


Assuntos
Anticonvulsivantes/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Ácido Valproico/sangue , Cromatografia Líquida/métodos , Biologia Computacional/métodos , Humanos , Limite de Detecção
12.
Artigo em Inglês | MEDLINE | ID: mdl-29549742

RESUMO

The main analytical targets of synthetic cannabinoids are often metabolites. With the high number of new psychoactive substances entering the market, suitable workflows are needed for analytical target identification in biological samples. The aims of this study were to identify the main metabolites of the synthetic cannabinoids, AMB-CHMICA and 5C-AKB48, using an in silico-assisted workflow with analytical data acquired using ultra-high-performance liquid chromatography-(ion mobility spectroscopy)-high resolution-mass spectrometry in data-independent acquisition mode (UHPLC-(IMS)-HR-MSE). The metabolites were identified after incubation with rat and pooled human hepatocytes using UHPLC-HR-MSE, followed by UHPLC-IMS-HR-MSE. Metabolites of AMB-CHMICA and 5C-AKB48 were predicted with Meteor (Lhasa Ltd) and imported to the UNIFI software (Waters). The predicted metabolites were assigned to analytical components supported by the UNIFI in silico fragmentation tool. The main metabolic pathway of AMB-CHMICA was O-demethylation and hydroxylation of the methylhexyl moiety. For 5C-AKB48, the main metabolic pathways were hydroxylation(s) of the adamantyl moiety and oxidative dechlorination with subsequent oxidation to the ω-COOH. The matrix components in the metabolite spectra were reduced with IMS, which improved the accuracy of the spectral interpretation; however, this left fewer fragment ions for assigning sites of metabolism. Meteor was able to predict the majority of the metabolites, with the most notable exception being the oxidative dechlorination and, consequently, all metabolites that underwent that transformation pathway. Oxidative dechlorination of ω-chloroalkanes in humans has not been previously reported in the literature. The postulated metabolites can be used for screening of biological samples, with four-dimensional identification based on retention time, collision cross section, precursor ion, and fragment ions.


Assuntos
Canabinoides/metabolismo , Cromatografia Líquida de Alta Pressão/métodos , Hepatócitos/metabolismo , Drogas Ilícitas/metabolismo , Adamantano/análise , Adamantano/química , Adamantano/metabolismo , Animais , Canabinoides/análise , Canabinoides/química , Humanos , Drogas Ilícitas/análise , Drogas Ilícitas/química , Indóis/análise , Indóis/química , Indóis/metabolismo , Espectrometria de Massas/métodos , Ratos
13.
J Chromatogr A ; 1542: 82-88, 2018 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-29472071

RESUMO

Exact mass, retention time (RT), and collision cross section (CCS) are used as identification parameters in liquid chromatography coupled to ion mobility high resolution accurate mass spectrometry (LC-IM-HRMS). Targeted screening analyses are now more flexible and can be expanded for suspect and non-targeted screening. These allow for tentative identification of new compounds, and in-silico predicted reference values are used for improving confidence and filtering false-positive identifications. In this work, predictions of both RT and CCS values are performed with machine learning using artificial neural networks (ANNs). Prediction was based on molecular descriptors, 827 RTs, and 357 CCS values from pharmaceuticals, drugs of abuse, and their metabolites. ANN models for the prediction of RT or CCS separately were examined, and the potential to predict both from a single model was investigated for the first time. The optimized combined RT-CCS model was a four-layered multi-layer perceptron ANN, and the 95th prediction error percentiles were within 2 min RT error and 5% relative CCS error for the external validation set (n = 36) and the full RT-CCS dataset (n = 357). 88.6% (n = 733) of predicted RTs were within 2 min error for the full dataset. Overall, when using 2 min RT error and 5% relative CCS error, 91.9% (n = 328) of compounds were retained, while 99.4% (n = 355) were retained when using at least one of these thresholds. This combined prediction approach can therefore be useful for rapid suspect/non-targeted screening involving HRMS, and will support current workflows.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia de Fase Reversa , Espectrometria de Massas , Peso Molecular , Redes Neurais de Computação
14.
Drug Test Anal ; 9(7): 1052-1061, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27750404

RESUMO

High-resolution mass spectrometry (HRMS) is widely used for the drug screening of biological samples in clinical and forensic laboratories. With the continuous addition of new psychoactive substances (NPS), keeping such methods updated is challenging. HRMS allows for combined targeted and non-targeted screening. First, peaks are identified by software algorithms, and identifications are based on reference standard data. Attempts are made to identify the remaining unknown peaks with in silico and literature data. However, several thousand peaks remain where most are unidentifiable or uninteresting in drug screening. The aims of the study were to apply a combined targeted and non-targeted screening approach to authentic driving-under-the-influence-of-drugs (DUID) samples (n = 44) and further validate the approach using whole-blood samples spiked with 11 low-dose synthetic benzodiazepine analogues (SBAs). Analytical data were acquired using ultra-high-performance liquid chromatography coupled with a time-of-flight mass spectrometer (UHPLC-TOF-MS) with data-independent acquisition (DIA). We present a combined targeted and non-targeted screening, where peak deconvolution and filtering reduced the number of peaks to inspect by three orders of magnitude, down to four peaks per DUID sample. The screening allowed for tentative identification of metabolites and drugs not included in the initial screening; 3 drugs and 14 metabolites were tentatively identified in the authentic DUID samples. Running targeted-screening true-positive identifications through the filters retained 73% of identifications. In the non-targeted screening, nine of the spiked SBAs were identified in the concentration range of 0.005-0.1 mg/kg, of which three were tentatively identified at concentrations below those reported in the literature. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Benzodiazepinas/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Psicotrópicos/sangue , Detecção do Abuso de Substâncias/métodos , Benzodiazepinas/análise , Benzodiazepinas/metabolismo , Dirigir sob a Influência , Humanos , Limite de Detecção , Psicotrópicos/análise , Psicotrópicos/metabolismo , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS