1.
Hip Int ; 28(3): 234-239, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-30165761

RESUMO

AIMS: To determine which of 3 methods of cup insertion most accurately achieved a target apparent operative inclination (AOI) of 35° ± 2.5°: (1) Freehand; (2) Modified Mechanical Alignment Guide (MAG); or (3) Digital Inclinometer assisted. METHODS: Using a cementless cup via a posterior approach in lateral decubitus 270 participants were recruited, with 90 randomised to each method. The primary outcome was the unsigned deviation from target AOI. The digital inclinometer was used to measure AOI in all cases, though the surgeon remained blinded to the reading intraoperatively for both the Freehand and MAG methods. RESULTS: Mean deviation from target AOI for the Freehand, Modified 35° MAG and Digital Inclinometer techniques was 2.9°, 1.8° and 1.3° respectively. When comparing mean deviation from target AOI, statistically significant differences between the Freehand / Inclinometer groups ( p < 0.001), the Freehand / Modified 35° MAG groups ( p < 0.001) and the Digital Inclinometer / Modified 35° MAG groups ( p < 0.023) were evident. The Digital Inclinometer technique enabled the surgeon to achieve a target AOI of 35° ± 2.5° in 88% of cases, compared to 71% of Modified 35° MAG cases and only 51% of Freehand cases. DISCUSSION: The Digital Inclinometer and the Modified 35° MAG techniques were both more accurate than the Freehand technique, with the Digital Inclinometer technique proving most accurate overall. Radiographic inclination (RI) is also influenced by operative anteversion; however, the greatest source of error with respect to RI occurs when the pelvic sagittal plane is not horizontal at the time of acetabular component insertion. Clinical Trial Protocol number: NCT01831401.


Assuntos
Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Idoso , Feminino , Prótese de Quadril , Humanos , Masculino , Posicionamento do Paciente , Pelve
2.
Hip Int ; 28(3): 240-245, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-30165765

RESUMO

INTRODUCTION: The study aims were to identify the incidence of pelvic adduction during total hip arthroplasty (THA) in lateral decubitus and to determine, when aiming for 35° of apparent operative inclination (AOI), which of 3 operating table positions most accurately obtained a target radiographic inclination (RI) of 42°: (1) horizontal; (2) 7° head-down; (3) patient-specific position based on correction of pelvic adduction. METHODS: With patients seated on a levelled theatre table, a ruler incorporating a spirit level was used to draw transverse pelvic lines (TPLs) on the skin overlying the pelvis and sacrum. Subsequently, when positioned in lateral decubitus these lines provided a measure of pelvic adduction. 270 participants were recruited, with 90 randomised to each group for operating table position. In all cases target AOI was 35°, aiming to achieve a target RI of 42°. The primary outcome measure was absolute (unsigned) deviation from the target RI of 42°. RESULTS: 266/270 patients demonstrated pelvic adduction (overall mean 4.4°, range 0- 9.2°). No patients demonstrated pelvic abduction. There were significant differences in RI between each of the 3 groups. The horizontal table group displayed the highest mean RI. The patient specific table position group achieved the smallest absolute deviation from target RI of 42°. DISCUSSION: In lateral decubitus, unrecognised pelvic adduction is common and is an important contributor to unexpectedly high RI. The use of preoperative TPLs helps identify pelvic adduction and its subsequent correction reduces variability in RI. Clinical Trial Protocol number: NCT01831401.


Assuntos
Artroplastia de Quadril/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Idoso , Feminino , Humanos , Masculino , Posicionamento do Paciente , Pelve , Estudos Prospectivos , Radiografia , Amplitude de Movimento Articular
3.
J Bone Joint Surg Am ; 96(6): 488-93, 2014 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-24647505

RESUMO

BACKGROUND: During total hip arthroplasty, use of a modular femoral neck on a stemmed implant allows optimization of neck anteversion, length, and offset, resulting in more accurate balance. We performed a retrospective analysis of a consecutive cohort of patients who had undergone total hip arthroplasty with a modular-neck hip system with ceramic-on-ceramic bearings. METHODS: We reviewed the results in fifteen patients who had received an ABG II dual modular hip system (Stryker Orthopaedics, Mahwah, New Jersey) from May 2007 to August 2008. Anteroposterior radiographs of the pelvis were reviewed and scored with regard to medial calcar erosion. Magnetic resonance imaging (MRI) was performed to assess for adverse local tissue reaction around the hip joint. Calcar resorption was correlated with subsequent MRI findings. Retrieval analysis was performed on the implants removed at revision. RESULTS: The mean duration of follow-up for all patients was 42.3 months (range, thirty-three to sixty months). Cobalt-ion levels were elevated in all patients; chromium levels were within the normal range. Medial femoral calcar erosion was noted in seven of the fifteen cases. All patients with grade-2 or 3 calcar erosion on radiographs had positive MRI findings consistent with adverse local tissue reaction. At the time of writing, seven patients had undergone revision arthroplasty. Intraoperatively, tissue staining with tissue and bone necrosis and pseudotumor formation were observed in all revision cases. Histological analysis confirmed the presence of metal-on-metal synovitis, with changes similar to those seen with metal-on-metal bearings. CONCLUSIONS: The ABG II dual modular hip system is associated with a high rate of early failure secondary to fretting and corrosion at the femoral neck-stem taper. The component has subsequently been recalled and is no longer in use. Surgeons using modular hip systems with a titanium stem and cobalt-chromium neck should be vigilant about annual follow-up with radiographs, and use of MRIs as indicated.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Falha de Prótese , Idoso , Cromo/sangue , Cobalto/sangue , Corrosão , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Estudos Retrospectivos
4.
J Arthroplasty ; 28(6): 1000-4, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23523213

RESUMO

We present a technique of single posterior longitudinal slot femorotomy. This technique allows the expansion of the metaphyseal-diaphyseal region of the proximal femur facilitating extraction of proximally coated uncemented femoral components while leaving the metaphysis and diaphysis intact. Since 1996 we have performed this technique in 18 revision total hip arthroplasties in 15 patients who had x-ray appearance of bony in-growth/on-growth and where found to have solidly ingrown stems at revision surgery. All were revised to a metaphyseally fitting uncemented stem. At mean follow-up of 122.4 months, there were significant improvements in both pain and function. All revised stems achieved stable boney fixation. There were no complications due to this technique. No patient developed a limp or thigh pain postoperatively. There have been no re-revisions of the stem. With appropriate patient selection, this is a simple, reliable, and extensile technique is useful to assist in the extraction of uncemented proximally coated femoral components whether hydroxyapatite-coated or not.


Assuntos
Artroplastia de Quadril , Remoção de Dispositivo/métodos , Fêmur/cirurgia , Prótese do Joelho , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS