Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 2370, 2023 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-36759533

RESUMO

The study was aimed to evaluate the performance of a newly developed spectroscopy-based non-invasive and noncontact device (SAMIRA) for the simultaneous measurement of hemoglobin, bilirubin and oxygen saturation as an alternative to the invasive biochemical method of blood sampling. The accuracy of the device was assessed in 4318 neonates having incidences of either anemia, jaundice, or hypoxia. Transcutaneous bilirubin, hemoglobin and blood saturation values were obtained by the newly developed instrument which was corroborated with the biochemical blood tests by expert clinicians. The instrument is trained using Artificial Neural Network Analysis to increase the acceptability of the data. The artificial intelligence incorporated within the instrument determines the disease condition of the neonate. The Pearson's correlation coefficient, r was found to be 0.987 for hemoglobin estimation and 0.988 for bilirubin and blood gas saturation respectively. The bias and the limits of agreement for the measurement of all the three parameters were within the clinically acceptance limit.


Assuntos
Bilirrubina , Hemoglobinas , Saturação de Oxigênio , Oxigênio , Sistemas Automatizados de Assistência Junto ao Leito , Análise Espectral , Humanos , Recém-Nascido , Inteligência Artificial , Bilirrubina/sangue , Hemoglobinas/análise , Oxigênio/sangue , Análise Espectral/instrumentação , Análise Espectral/métodos , Imagem Óptica/instrumentação , Imagem Óptica/métodos
2.
Biosens Bioelectron ; 218: 114764, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36206669

RESUMO

Urinary bladder cancer (UBC) is one of the most common cancers and has notoriously high risk of recurrence and mortality across the globe. Current clinical initial diagnostic approaches are either invasive or lacks sensitivity. In this study, an attempt has been made to invent a cost-effective, novel, portable diagnostic device based on the environmental sensitive fluorophores namely Nile Red (NR), Eosin Y (EY) and Rose Bengal (RB). They act as sensing agents for detecting volatile organic compounds (VOC) exclusively present in the urine sample of UBC patients and differentiate the UBC samples from the healthy control group. Upon exposure with a particular group of VOCs, a significant amount of increment in fluorescence intensities of NR, EY and RB were detected and recorded in our indigenously developed "NABIL" device. To check the performance of NABIL, the data collected from the device was compared with the conventional techniques by arranging a clinical trial with 21 healthy controls and 52 UBC patients. With the assistance of our analysis technique based on LabVIEW platform, very high sensitivity and accuracy from healthy controls have been achieved. For UBC patients, it shows impressive diagnostic results. In addition, depending on the sample processing mechanism, NABIL device can also reveal the grade of UBC and prognosis under treatment. Overall, this study contributes a novel, non-invasive, easy-to-use, inexpensive, real-time, accurate method for selectively UBC diagnosis, which can be useful for personalized care/diagnosis and postoperative surveillance, resulting in saving more lives.


Assuntos
Técnicas Biossensoriais , Neoplasias da Bexiga Urinária , Compostos Orgânicos Voláteis , Humanos , Biomarcadores , Biomarcadores Tumorais/urina , Amarelo de Eosina-(YS) , Rosa Bengala , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/urina
3.
Rev Sci Instrum ; 93(5): 054101, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35649790

RESUMO

We developed an integrated device composed of a single-probe Electroencephalogram (EEG) and Charge Coupled Device (CCD) based motion sensors for objective measurement of Attention-deficit Hyperactivity Disorder (ADHD). While the measurement of attention-deficit hyperactivity disorder (MAHD) relies on the EEG signal for the assessment of attention during a given structured task, the CCD sensor depicts the movement pattern of the subjects engaged in a continuous performance task. A statistical analysis of attention and movement patterns was performed, and the accuracy of completed tasks was analyzed using indigenously developed software. The device with the embedded software is intended to improve certainty with criterion E. We used the EEG signal from a single-channel dry sensor placed on the frontal lobe of the head of the subjects (3-5 year old pre-schoolers). During the performance of the task power for delta and beta, EEG waves from the subjects are found to be correlated with relaxation and attention/cognitive load conditions. While the relaxation condition of the subject hints at hyperactivity, a more direct CCD-based motion sensor is used to track the physical movement of the subject engaged in a continuous performance task. We used our indigenously developed software for statistical analysis to derive a scale for the objective assessment of ADHD. We also compared our scale with clinical ADHD evaluations and found a significant correlation between the objective assessment of the ADHD subjects and the clinician's conventional evaluation. MAHD, the integrated device, is supposed to be an auxiliary tool to improve the accuracy of ADHD diagnosis by supporting greater criterion E certainty.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico , Transtorno do Deficit de Atenção com Hiperatividade/psicologia , Pré-Escolar , Eletroencefalografia , Humanos
4.
Phys Chem Chem Phys ; 24(10): 6176-6184, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35229087

RESUMO

The potentiality of Förster resonance energy transfer (FRET) for studying molecular interactions inside biological tissues with improved spatial (Angström) and temporal (picosecond) resolution is well established. On the other hand, the efficacy of diffuse reflectance spectroscopy (DRS) that uses optical radiation in order to determine physiological parameters including haemoglobin, and oxygen saturation is well known. Here we have made an attempt to combine diffuse reflectance spectroscopy (DRS) with picosecond-resolved FRET in order to show improvement in the exploration of molecular contacts in biological tissue models. We define the technique as ultrafast time-resolved diffuse reflectance spectroscopy (UTRDRS). The illuminated photon of the fluorophore from the surface of the tissue-mimicking layers carries the hidden information of the molecular contact. In order to investigate the validation of the Kubelka-Munk (KM) formulism for the developed UTRDRS technique in tissue phantoms, we have studied the propagation of incandescent and picosecond-laser light through several layers of cellulose membranes. While picosecond-resolved FRET in the diffuse reflected light confirms the hidden nano-contact (4.6 nm) of two different dye layers (8-anilino-1-naphthalenesulfonic acid and Nile blue), high-resolution optical microscopy on the cross-section of the layers reveals the proximity and contacts of the layers with limited spatial resolution (∼300 nm). We have also investigated two biologically relevant molecules, namely carboxyfluorescein and haemoglobin, in tissue phantom layers in order to show the efficacy of the UTRDRS technique. Overall, our studies based on UTRDRS in tissue mimicking layers may have potential applications in non-invasive biomedical diagnosis for patients suffering from skin diseases.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Luz , Transferência Ressonante de Energia de Fluorescência/métodos , Corantes Fluorescentes , Hemoglobinas , Humanos , Análise Espectral
5.
Trans Indian Natl Acad Eng ; 6(2): 355-364, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35837575

RESUMO

Regular monitoring of electrolyte balance is essential for patients suffering from chronic kidney disease (CKD), particularly those undergoing dialysis. In the context of the recent COVID-19 pandemic, more severe forms of infection are observed in elderly individuals and patients having co-morbidities like CKD. The repeated blood tests for the monitoring of electrolyte balance predispose them not only to COVID-19 but also other to hospital-acquired infections (HAI). Therefore, a non-invasive method for easy detection of essential electrolyte (K+ and Na+) levels is urgently needed. In this study, we developed an optical emission spectroscopy-based non-invasive device for simultaneous monitoring of salivary Na+ and K+ levels in a fast and reliable way. The device consisted of a closed spark chamber, micro-spectrometer, high voltage spark generator, electronic circuits, optical fiber, and an indigenously developed software based on the LabVIEW platform. The optical emission originating from the biological sample (i.e., saliva) due to recombination of ions energized by impingement of electrons returning from high voltage spark provides necessary information about the concentration of electrolytes. A small-scale clinical trial on 30 healthy human subjects shows the potential of the indigenously developed device in determining salivary Na + and K+ concentration. The low-cost, portable, point-of-care device requires only 2 mL of sample, and can simultaneously measure 1.0-190.0 mM Na+, and 1.0-270.9 mM K+ . To our understanding, the present work will find its relevance in combating COVID-19 morbidities, along with regular CKD patient-care.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...