Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38733024

RESUMO

The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants' bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland-Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment.


Assuntos
Smartphone , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Reprodutibilidade dos Testes , Acidentes por Quedas/prevenção & controle
2.
BMC Infect Dis ; 24(1): 130, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267905

RESUMO

BACKGROUND: Leprosy is a chronic infectious disease caused by Mycobacterium leprae, predominantly affecting the peripheral nerves, resulting in sensory and motor deficits in the feet. Foot ulcers and imbalances are frequent manifestations in leprosy, often correlating with diminished sensitivity. While clinical scales and monofilament esthesiometers are conventionally utilized to evaluate foot sensitivity and balance in these patients, their discriminatory power is limited and their effectiveness is greatly dependent on the examiner's proficiency. In contrast, baropodometry and posturography offer a more comprehensive evaluation, aiming to preempt potential damage events. This study aimed was to assess the correlation between baropodometry and force plate measurements in leprosy patients and control participants, to improve the prevention and treatment of foot ulcers and complications associated with leprosy. METHODOLOGY: This cross-sectional study was conducted during 2022 and enrolled 39 participants (22 patients with multibacillary leprosy and 17 non-leprosy controls). Demographic data were collected, and a monofilament esthesiometer was used to assess sensory deficits. In addition, physical examinations and balance and plantar pressure tests were conducted. The Student's t-test was used to compare mean and maximum plantar pressures between groups. For most COP variables, a Mann-Whitney Wilcoxon test was used, except for AP amplitude which was analyzed with the Student's t-test due to its normal distribution. The relationship between foot pressure and balance control was assessed using Spearman's correlation, focusing on areas with significant pressure differences between groups. PRINCIPAL FINDINGS: Leprosy patients showed increased pressure in forefoot areas (T1, M1, T2-T5, and M2) and decreased pressure in hindfoot regions (MH and LH) compared to controls. These patients also displayed higher AP and ML amplitudes, suggesting poorer COP control. Correlation analyses between the two groups revealed that foot plantar pressures significantly impact balance control. Specifically, increased T1 region pressures correlated with greater sway in balance tasks, while decreased MH region pressures were linked to reduced COP control. CONCLUSIONS/SIGNIFICANCE: The findings suggest a joint disturbance of plantar pressure distribution and static balance control in leprosy patients. These alterations may increase the risk of tissue injuries, including calluses and deformities, as well as falls.


Assuntos
Pé Diabético , Hanseníase Multibacilar , Humanos , Estudos Transversais , , Extremidade Inferior
3.
PLOS Digit Health ; 2(8): e0000304, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37585430

RESUMO

The Finger Tapping Test (FTT) is a classical neuropsychological test that assesses motor functioning, and recently it has been employed using smartphones. For classical protocols, it has been observed that sex and handedness influence the performance during the test. By assessing the influence of sex and handedness on the test, it is possible to adjust the performance measurements to ensure the validity of test results and avoid sex- and handedness-related bias. The present study aimed to evaluate the influence of sex and handedness on smartphone-based FTT performance. We developed an Android application for the FTT and recruited 40 males and 40 females to carry out three spatial designs on it (protocols I, II, and III). Participants' performance was measured using the global, temporal, and spatial parameters of the FTT. We observed that for the performance in protocol I, handedness had a significant influence on global and temporal variables, while the interaction between handedness and sex had a greater influence on spatial variables. For protocols II and III, we observed that handedness had a significant influence on global, temporal, and spatial variables compared to the other factors. We concluded that the smartphone-based test is partly influenced by handedness and sex, and in clinical implications, these factors should be considered during the evaluation of the smartphone-based FTT.

4.
Front Neurosci ; 17: 1130867, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37404467

RESUMO

The scientific need for standardized, high-quality facial stimuli has driven the creation of several face image databases in recent years. These stimuli are particularly important in facial asymmetry research. However, previous studies have reported facial anthropometric differences across a variety of ethnicities. This highlights the need to investigate whether these differences can also impact the use of face image databases, particularly in facial asymmetry research. In this study, we investigated facial asymmetry-based morphometric differences between the multi-ethnic Chicago Face Database (CFD) and the LACOP Face Database, which is composed of Brazilian subjects. We found reliable differences in facial asymmetry between the two databases, which were related to ethnic groups. Specifically, differences in eye and mouth asymmetry seem to drive these differences. The asymmetry-based morphometric differences among databases and ethnicities found in this study reinforce the necessity of creating multi-ethnic face databases.

5.
Sci Rep ; 12(1): 16808, 2022 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-36207392

RESUMO

Tremors are common disorders characterized by an involuntary and relatively rhythmic oscillation that can occur in any part of the body and may be physiological or associated with some pathological condition. It is known that the mass loading can change the power spectral distribution of the tremor. Nowadays, many instruments have been used in the evaluation of tremors with bult-in inertial sensors, such as smartphones and wearables, which can significantly differ in the device mass. The aim of this study was to compare the quantification of hand tremor using Fourier spectral techniques obtained from readings of accelerometers built-in a lightweight handheld device and a commercial smartphone in healthy young subjects. We recruited 28 healthy right-handed subjects with ages ranging from 18 to 40 years. We tested hand tremors at rest and postural conditions using lightweight wearable device (5.7 g) and smartphone (169 g). Comparing both devices at resting tremor, we found with smartphone the power distribution of peak ranging 5 and 12 Hz in both hands. With wearable, the result was similar but less evident. When comparing both devices in postural tremor, there were significant differences in both frequency ranges in peak frequency and peak amplitude in both hands. Our main findings show that in resting condition the hand tremor spectrum had a higher peak amplitude in the 5-12 Hz range when the tremor was recorded with smartphones, and in postural condition there was a significantly (p < 0.05) higher peak power spectrum and peak frequency in the dominant hand tremors recorded with smartphones compared to those obtained with lightweight wearable device. Devices having different masses can alter the features of the hand tremor spectrum and their mutual comparisons can be prejudiced.


Assuntos
Tremor , Dispositivos Eletrônicos Vestíveis , Adolescente , Adulto , Mãos , Humanos , Smartphone , Tremor/complicações , Tremor/diagnóstico , Extremidade Superior , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...