Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(18)2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37765805

RESUMO

In this paper, an inductive wireless link for motion recognition is investigated. In order to validate the feasibility of a wearable implementation, the use of three different materials is analyzed: a thin copper wire, a conductive yarn, and a conductive non-woven fabric. Results from the application of the developed devices on an arm are reported and discussed. It is demonstrated that the proposed textile inductive resonant wireless links are well suited for developing a compact wearable system for joint flexion recognition.

2.
Sensors (Basel) ; 23(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36992061

RESUMO

In this paper, wristband electrodes for hand-to-hand bioimpedance measurements are investigated. The proposed electrodes consist of a stretchable conductive knitted fabric. Different implementations have been developed and compared with Ag/AgCl commercial electrodes. Hand-to-hand measurements at 50 kHz on forty healthy subjects have been carried out and the Passing-Bablok regression method has been exploited to compare the proposed textile electrodes with commercial ones. It is demonstrated that the proposed designs guarantee reliable measurements and easy and comfortable use, thus representing an excellent solution for the development of a wearable bioimpedance measurement system.


Assuntos
Têxteis , Extremidade Superior , Humanos , Eletrodos , Condutividade Elétrica , Mãos
3.
Sensors (Basel) ; 22(17)2022 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-36080855

RESUMO

The aim of this work is to propose two different and integrated sensors for the structural health monitoring of concrete beams. In particular, a diffused sensing element and a split ring resonator network are presented. The first sensor is able to detect the variations in the dielectric properties of the concrete along the whole beam length, for a diffuse monitoring both during the important concrete curing phase and also for the entire life cycle of the concrete beams. The resonators instead work punctually, in their surroundings, allowing an accurate evaluation of the permittivity both during the drying phase and after. This allows the continuous monitoring of any presence of water both inside the concrete beam and at points that can be critical, in the case of beams in dams, bridges or in any case subject to a strong presence of water which could lead to deterioration, or worse, cause serious accidents. Moreover, the punctual sensors are able to detect the presence of cracks in the structure and to localize them.


Assuntos
Água
4.
Sensors (Basel) ; 20(10)2020 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-32429375

RESUMO

One of the major goals of Health 4.0 is to offer personalized care to patients, also through real-time, remote monitoring of their biomedical parameters. In this regard, wearable monitoring systems are crucial to deliver continuous appropriate care. For some biomedical parameters, there are a number of well established systems that offer adequate solutions for real-time, continuous patient monitoring. On the other hand, monitoring skin hydration still remains a challenging task. The continuous monitoring of this physiological parameter is extremely important in several contexts, for example for athletes, sick people, workers in hostile environments or for the elderly. State-of-the-art systems, however, exhibit some limitations, especially related with the possibility of continuous, real-time monitoring. Starting from these considerations, in this work, the feasibility of an innovative time-domain reflectometry (TDR)-based wearable, skin hydration sensing system for real-time, continuous monitoring of skin hydration level was investigated. The applicability of the proposed system was demonstrated, first, through experimental tests on reference substances, then, directly on human skin. The obtained results demonstrate the TDR technique and the proposed system holds unexplored potential for the aforementioned purposes.


Assuntos
Pele , Dispositivos Eletrônicos Vestíveis , Idoso , Estudos de Viabilidade , Humanos , Monitorização Fisiológica , Água/análise
5.
Sensors (Basel) ; 20(2)2020 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-31940878

RESUMO

In this work, two fully-textile wearable devices, to be used as chipless identification tags in identification and tracking applications are presented. For the fabrication of the fully-textile tags, a layer of fleece was used as a substrate, while an adhesive non-woven conductive fabric was employed for the conductive parts. To allow radio-frequency identification of these chipless tags, two alternative techniques were used. One relies on associating a binary code with the resonance frequency of resonant devices: the presence/absence of the resonance peaks in the transmission scattering parameter, | S 21 | , of a set of resonators is used to encode a string of bits. The second technique for accomplishing radio-frequency identification of the chipless tags resorts to a frequency-shift coding technique, which is implemented by modifying the configuration of a hairpin resonator. The obtained numerical and experimental results confirm the suitability of the proposed strategies for obtaining entirely-textile, wearable chipless tags for identification and tracking purposes, which can be particularly useful, especially in the industrial sector. In this field, in fact, the proposed solutions would guarantee a seamless integration with clothes and would facilitate the user's interaction with the IoT infrastructure. In this regard, one of the envisaged application scenarios related to the tracking of hides in the leather industry is also presented.

6.
Sensors (Basel) ; 19(3)2019 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30691032

RESUMO

In this paper, a frequency-signature Radio-Frequency Identification (RFID) chipless tag for wearable applications is presented. The results achieved for a fully-textile solution guaranteeing a seamless integration in clothes are reported and discussed. The proposed tag consists of two planar monopole antennas and a 50 Ω microstrip line loaded with multiple resonators. In order to achieve a compact size, the resonators are slotted on the ground plane of the microstrip line. As for the antennas, the same geometry was exploited for both the TX and the RX tag antenna. In particular, it consists of a proximity fed planar monopole on a ground plane. The selected geometry guarantees easy integration with the multi-resonator structure. Numerical and experimental data referring to a 2-bit implementation are presented and discussed. For fabricating all the prototypes, a layer of pile was used as a substrate, while an adhesive non-woven conductive fabric was exploited for the fabrication of the conductive parts. Experimental tests demonstrate that although the performance of the final device strongly depends on the properties of the used materials and on the imperfections of the fabrication process, the proposed frequency-signature RFID chipless tag is suitable for wearable applications, such as anti-counterfeiting systems and laundry labels.

7.
ACS Appl Mater Interfaces ; 5(8): 2908-14, 2013 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-23537058

RESUMO

We show that assembled domains of magnetic iron-oxide nanoparticles (IONPs) are effective at increasing the dielectric permittivity of polydimethylsiloxane (PDMS) nanocomposites in the GHz frequency range. The assembly has been achieved by means of magnetophoretic transport and its efficacy, as well as the electromagnetic properties of the nanocomposite, has been found to depend on IONPs diameter. Remarkably, the dielectric permittivity increase has been obtained by keeping dielectric and magnetic losses very low, making us envision the suitability of nanocomposites based on aligned IONPs as substrates for radiofrequency applications.


Assuntos
Compostos Férricos/química , Nanopartículas/química , Nanotecnologia/instrumentação , Polímeros/química , Nanocompostos/química , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...