Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Anal Toxicol ; 31(3): 125-31, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17579958

RESUMO

A qualitative liquid chromatography-tandem mass spectrometry method for the analysis of 22 sporting federation-banned anabolic agents (or their metabolite markers) and anti-estrogens in urine that are refractory to analysis by gas chromatography-mass spectrometry is presented. In addition, a quantitative method built around World Anti-Doping Agency (WADA) guidelines for the confirmatory analysis of 19-norandrosterone, the primary metabolite of nandrolone with a WADA-specified minimum required performance limit of 1 ng/mL, is included. Hydrolysis of glucuronide conjugates, liquid-liquid extraction, no clean-up derivatization with Girard's Reagent P, and analysis by quadrupole-time-of-flight mass spectrometry provide sensitivity and selectivity well beyond that required by the WADA.


Assuntos
Anabolizantes/urina , Cromatografia Líquida de Alta Pressão , Dopagem Esportivo , Estranos/urina , Moduladores de Receptor Estrogênico/urina , Espectrometria de Massas por Ionização por Electrospray , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem , Guias como Assunto , Humanos , Agências Internacionais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Anal Toxicol ; 30(1): 50-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16620532

RESUMO

This study compared the ability of two on-site testing devices, Instant-View Test Card and OnTrak TesTcup Pro 5, to discriminate negative from positive urine samples for cannabinoids, cocaine metabolite, opiates, amphetamines, and benzodiazepines. The on-site devices were evaluated in a precision study with fortified urine samples and in a clinical study with samples submitted for forensic urine drug testing. For precision, seven stocks were prepared per device. Each stock had all five analytes added in a random fashion at 0, 25, 50, 75, 125, 150, or 175% of cutoff. Ten aliquots per stock were assigned random numbers and analyzed by two individuals. The respective accuracies (defined as "% below cutoff samples that were negative + % above cutoff samples that were positive") for Instant-View Test Card and TesTcup were 74.3 and 87.1 for amphetamines; 82.1 and 90.7 for benzoylecgonine; 88.6 and 90.7 for benzodiazepines; 83.6 and 94.3 for morphine; 82.1 and 87.9 for cannabinoids; and 82.1 and 90.1% overall. In contrast to the on-site testing devices, instrumental testing with OnLine reagents had perfect precision. For the clinical study, submitted samples that had reached their disposal date were rescreened for the five drug groups. Fifty that had absorbance changes near the negative control for all five drug groups were selected as "negatives"; 240 samples with positive or multi-positive results (some between the 75% control and cutoff) and confirmed by GC-MS were chosen as "positives" (at least 45 per drug group). The non-positive drug groups in these samples added 150 additional presumptively negatives per drug group. Samples were assigned random numbers, and two individuals tested each sample. The respective accuracies in respect to GC-MS results for Instant-View Test Card and TesTcup were 95.8 and 91.7 for amphetamines; 100 and 100 for benzoylecgonine; 96.7 and 96.5 for benzodiazepines; 98.8 and 99.2 for opiates; 94.4 and 95.0 for cannabinoids; and 97.1 and 96.5% overall. The clinical study revealed that the Instant-View Test Card had low cross-reactivity (i.e., false negatives) for samples with amphetamine only and oxycodone. TesTcup had low cross-reactivity for samples with amphetamine only and hydrocodone and/or hydromorphone; it also had more cross-reactivity towards (i.e., false positives) sympathomimetic amines. In summary, the Instant-View Test Card was less precise than the TesTcup at or near the cutoff; with clinical samples, however, the percent accuracies of the two devices were similar.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Drogas Ilícitas/urina , Imunoensaio , Sistemas On-Line , Detecção do Abuso de Substâncias/métodos , Urinálise/métodos , Medicina Legal/métodos , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias/instrumentação , Urinálise/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...