Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Chem ; 10: 976635, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36092655

RESUMO

Flerovium (Fl, element 114) is the heaviest element chemically studied so far. To date, its interaction with gold was investigated in two gas-solid chromatography experiments, which reported two different types of interaction, however, each based on the level of a few registered atoms only. Whereas noble-gas-like properties were suggested from the first experiment, the second one pointed at a volatile-metal-like character. Here, we present further experimental data on adsorption studies of Fl on silicon oxide and gold surfaces, accounting for the inhomogeneous nature of the surface, as it was used in the experiment and analyzed as part of the reported studies. We confirm that Fl is highly volatile and the least reactive member of group 14. Our experimental observations suggest that Fl exhibits lower reactivity towards Au than the volatile metal Hg, but higher reactivity than the noble gas Rn.

2.
Appl Radiat Isot ; 143: 163-175, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30447627

RESUMO

Nuclear fusion experiments performed at the National Ignition Facility produce radioactive debris, arising in reactions of fast neutrons with the target assembly. We have found that postshot debris collections are fractionated, such that isotope ratios in an individual debris sample may not be representative of the radionuclide inventory produced by the experiment. We discuss the potential sources of this fractionation and apply isotope-correlation techniques to calculate unfractionated isotope ratios that are used in measurements of nuclear reaction cross sections.

3.
Rev Sci Instrum ; 89(10): 10I133, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399665

RESUMO

A large area solid radiochemistry collector was deployed at the National Ignition Facility (NIF) with a collection efficiency for post-shot, solid target debris of approximately 1% of the total 4π solid angle. The collector consisted of a 20-cm diameter vanadium foil surrounded by an aluminum side-enclosure and was fielded 50 cm from the NIF target. The collector was used on two NIF neutron yield shots, both of which had a monolayer of 238U embedded in the capsule ablator 10 µm from the inner surface. Fission and activation products produced in the 238U were collected, and subsequent analyses via gamma spectroscopy indicated that the distribution of fission products was not uniform, with peak and valley fission products preferentially collected on the vanadium and low- and high-mass fission products primarily located on the aluminum side-enclosure. The results from these shots will be used to design future nuclear data experiments at NIF.

4.
Rev Sci Instrum ; 87(11): 11D813, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910632

RESUMO

The solid debris collection capability at the National Ignition Facility has been expanded to include a third line-of-sight assembly. The solid radiochemistry nuclear diagnostic measurement of the ratio of gold isotopes is dependent on the efficient collection of neutron-activated hohlraum debris by passive metal disks. The collection of target debris at this new location is more reliable in comparison to the historic locations, and it appears to be independent of collector surface ablation.

5.
Appl Radiat Isot ; 107: 199-202, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26524406

RESUMO

A high-purity carrier-free (7)Be was efficiently isolated following proton bombardment of a lithium hydroxide-aluminum target. The separation of beryllium from lithium and aluminum was achieved through a hydrochloric acid elution system utilizing cation exchange chromatography. The beryllium recovery, +99%, was assessed through gamma spectroscopy while the chemical purity was established by mass spectrometry. The decontamination factors of beryllium from lithium and aluminum were determined to be 6900 and 300, respectively.

6.
Rev Sci Instrum ; 86(7): 076105, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26233419

RESUMO

A new radiochemical method for determining deuterium-tritium (DT) fuel and plastic ablator (CH) areal densities (ρR) in high-convergence, cryogenic inertial confinement fusion implosions at the National Ignition Facility is described. It is based on measuring the (198)Au/(196)Au activation ratio using the collected post-shot debris of the Au hohlraum. The Au ratio combined with the independently measured neutron down scatter ratio uniquely determines the areal densities ρR(DT) and ρR(CH) during burn in the context of a simple 1-dimensional capsule model. The results show larger than expected ρR(CH) values, hinting at the presence of cold fuel-ablator mix.

7.
J Evol Biol ; 28(2): 503-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25522811

RESUMO

Parental care benefits offspring through maternal effects influencing their development, growth and survival. However, although parental care in general is likely the result of adaptive evolution, it does not follow that specific differences in the maternal effects that arise from care are also adaptive. Here, we used an interspecific cross-fostering design in the burying beetle species Nicrophorus orbicollis and N. vespilloides, both of which have elaborate parental care involving direct feeding of regurgitated food to offspring, to test whether maternal effects are optimized within a species and therefore adaptive. Using a full-factorial design, we first demonstrated that N. orbicollis care for offspring longer regardless of recipient species. We then examined offspring development and mass in offspring reared by hetero- or conspecific parents. As expected, there were species-specific direct effects independent of the maternal effects, as N. orbicollis larvae were larger and took longer to develop than N. vespilloides regardless of caregiver. We also found significant differences in maternal effects: N. vespilloides maternal care caused more rapid development of offspring of either species. Contrary to expectations if maternal effects were species-specific, there were no significant interactions between caretaker and recipient species for either development time or mass, suggesting that these maternal effects are general rather than optimized within species. We suggest that rather than coadaptation between parents and offspring performance, the species differences in maternal effects may be correlated with direct effects, and that their evolution is driven by selection on those direct effects.


Assuntos
Adaptação Fisiológica/genética , Besouros/fisiologia , Comportamento Materno/fisiologia , Animais , Besouros/genética , Feminino , Masculino , Especificidade da Espécie
8.
Rev Sci Instrum ; 85(6): 063508, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24985820

RESUMO

We describe a radiochemical measurement of the ratio of isotope concentrations produced in a gold hohlraum surrounding an Inertial Confinement Fusion capsule at the National Ignition Facility (NIF). We relate the ratio of the concentrations of (n,γ) and (n,2n) products in the gold hohlraum matrix to the down-scatter of neutrons in the compressed fuel and, consequently, to the fuel's areal density. The observed ratio of the concentrations of (198m+g)Au and (196g)Au is a performance signature of ablator areal density and the fuel assembly confinement time. We identify the measurement of nuclear cross sections of astrophysical importance as a potential application of the neutrons generated at the NIF.

9.
Phys Rev Lett ; 109(16): 162501, 2012 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-23215070

RESUMO

Two years after the discovery of element 117, we undertook a second campaign using the (249)Bk+(48)Ca reaction for further investigations of the production and decay properties of the isotopes of element 117 on a larger number of events. The experiments were started in the end of April 2012 and are still under way. This Letter presents the results obtained in 1200 hours of an experimental run with the beam dose of (48)Ca of about 1.5×10(19) particles. The (249)Bk target was irradiated at two energies of (48)Ca that correspond to the maximum probability of the reaction channels with evaporation of three and four neutrons from the excited (297)117. In this experiment, two decay chains of (294)117 (3n) and five decay chains of (293)117 (4n) were detected. In the course of the long-term work, (249)Cf-the product of decay of (249)Bk (330 d)-is being accumulated in the target. Consequently, in the present experiment, we also detected a single decay of the known isotope (294)118 that was produced during 2002-2005 in the reaction (249)Cf((48)Ca,3n)(294)118. The obtained results are compared with the data from previous experiments. The experiments are carried out in the Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, using the heavy-ion cyclotron U400.

10.
Rev Sci Instrum ; 83(10): 10D904, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126908

RESUMO

Radiochemical analysis of post-ignition debris inside the National Ignition Facility (NIF) target chamber can help determine various diagnostic parameters associated with the implosion efficiency of the fusion capsule. This technique is limited by the ability to distinguish ablator material from other debris and by the collection efficiency of the capsule debris after implosion. Prior to designing an on-line collection system, the chemical nature and distribution of the debris inside the chamber must be determined. The focus of our current work has been on evaluating capture of activated Au hohlraum debris on passive foils (5 cm diameter, 50 cm from target center) post-shot. Preliminary data suggest that debris distribution is locally heterogeneous along the equatorial and polar line-of-sights.

11.
Rev Sci Instrum ; 83(10): 10D917, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126919

RESUMO

The Radiochemical Analysis of Gaseous Samples (RAGS) diagnostic apparatus was recently installed at the National Ignition Facility (NIF). Following a NIF shot, RAGS is used to pump the gas load from the NIF chamber for purification and isolation of the noble gases. After collection, the activated gaseous species are counted via gamma spectroscopy for measurement of the capsule areal density and fuel-ablator mix. Collection efficiency was determined by injecting a known amount of (135)Xe into the NIF chamber, which was then collected with RAGS. Commissioning was performed with an exploding pusher capsule filled with isotopically enriched (124)Xe and (126)Xe added to the DT gas fill. Activated xenon species were recovered post-shot and counted via gamma spectroscopy. Results from the collection and commissioning tests are presented. The performance of RAGS allows us to establish a noble gas collection method for measurement of noble gas species produced via neutron and charged particle reactions in a NIF capsule.

12.
Phys Rev Lett ; 108(2): 022502, 2012 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-22324675

RESUMO

Results of a new series of experiments on the study of production cross sections and decay properties of the isotopes of element 115 in the reaction (243)Am+(48)Ca are presented. Twenty-one new decay chains originating from (288)115 were established as the product of the 3n-evaporation channel by measuring the excitation function at three excitation energies of the compound nucleus (291)115. The decay properties of all newly observed nuclei are in full agreement with those we measured in 2003. At the lowest excitation energy E*=33 MeV, for the first time we registered the product of the 2n-evaporation channel, (289)115, which was also observed previously in the reaction (249)Bk+(48)Ca as the daughter nucleus of the decay of (293)117. The maximum cross section for the production of (288)115 is found to be 8.5 pb at E*≈36 MeV.

13.
Phys Rev Lett ; 104(14): 142502, 2010 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-20481935

RESUMO

The discovery of a new chemical element with atomic number Z=117 is reported. The isotopes (293)117 and (294)117 were produced in fusion reactions between (48)Ca and (249)Bk. Decay chains involving 11 new nuclei were identified by means of the Dubna gas-filled recoil separator. The measured decay properties show a strong rise of stability for heavier isotopes with Z > or = 111, validating the concept of the long sought island of enhanced stability for superheavy nuclei.

14.
Rev Sci Instrum ; 79(10): 10E503, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044489

RESUMO

Understanding mix in inertial confinement fusion (ICF) experiments at the National Ignition Facility requires the diagnosis of charged-particle reactions within an imploded target. Radiochemical diagnostics of these reactions are currently under study by scientists at Los Alamos and Lawrence Livermore National Laboratories. Measurement of these reactions requires assay of activated debris and tracer gases from the target. Presented below is an overview of the prompt radiochemistry diagnostic development efforts, including a discussion of the reactions of interest as well as the progress being made to collect and count activated material.

15.
Phys Rev Lett ; 98(14): 142501, 2007 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-17501268

RESUMO

The energy splitting of the 229Th ground-state doublet is measured to be 7.6+/-0.5 eV, significantly greater than earlier measurements. Gamma rays produced following the alpha decay of 233U (105 muCi) were counted in the NASA/electron beam ion trap x-ray microcalorimeter spectrometer with an experimental energy resolution of 26 eV (FWHM). A difference technique was applied to the gamma-ray decay of the 71.82 keV level that populates both members of the doublet. A positive correction amounting to 0.6 eV was made for the unobserved interband decay of the 29.19 keV state (29.19-->0 keV).

16.
CLAO J ; 23(3): 161-7, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9240826

RESUMO

PURPOSE: Irregular corneal astigmatism has been reported in association with annular tinted hydrogel contact lenses. We report the abnormal videokeratographic findings of five patients wearing annular tinted contact lenses, who presented with bilateral blurred vision and revealed a loss of best corrected visual acuity. METHODS/RESULTS: The corneal topographic analysis revealed a previously unreported distinct ring-shaped pattern of irregular astigmatism. The topographic circular band of irregular astigmatism was further characterized by concentric areas of relative steepening, flattening, and steepening with a diameter of approximately 4 mm. This pattern suggests that forces acting at the junctional zone between the tinted area and the clear pupillary area are inducing structural abnormalities of the corneal surface. At the time of presentation, the mean surface regularity index (SRI) was 2.06 (range: 0.61-5.88). The topography and best-corrected visual acuity returned to normal within days of discontinuing annular tinted lens use, and the mean SRI decreased to 0.44 (range: 0.21-1.16). Digital imaging of lenses obtained from our patients and of identical control lenses was performed. A masked analysis suggested that the study lenses contain greater amounts of pigment compared to the control lenses. CONCLUSIONS: We present ten characteristic signs and symptoms of this condition, which we have named "the annular tinted contact lens syndrome." Corneal topographic analysis is a powerful tool for detecting specific reversible irregularities of the corneal surface associated with the use of annular tinted contact lenses.


Assuntos
Astigmatismo/etiologia , Lentes de Contato Hidrofílicas/efeitos adversos , Córnea/patologia , Processamento de Imagem Assistida por Computador/métodos , Adolescente , Adulto , Astigmatismo/diagnóstico , Feminino , Filtração , Humanos , Oftalmologia/instrumentação , Síndrome , Acuidade Visual
17.
CLAO J ; 23(2): 103-12, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9108975

RESUMO

PURPOSE: We characterized the clinical performance of the 1-Day Acuvue contact lens by direct comparison with four frequently prescribed daily wear lenses. METHODS: Forty-eight patients participated in four prospective, randomized masked clinical trials using the 1-Day Acuvue in one eye and the Medalist, Surevue, Acuvue (regular), and Biomedics 55 lenses in the other eye. Each trial lasted 2 weeks. Thirteen symptom variables and overall lens preference were evaluated using a patient preference questionnaire and a symptom-ranking questionnaire. Overnight corneal swell studies were also performed. RESULTS: In the non-allergic (58.4%) subgroup, the overall lens preference variable revealed a significant preference for the Medalist (P = .004), Surevue (P < .001), and Biomedics 55 (P < .001) lenses. In contrast, in the allergic (41.6%) subgroup, the overall lens preferences for the Medalist, Surevue, and Biomedics 55 lenses were completely absent. Multivariate regression analysis in the non-allergic subgroup revealed that lens comfort (.58, P < .001), lens handling upon insertion (.41, P < .001), and quality of vision (.35, P < .001) were significant variables contributing to patient responses regarding overall lens preference. However, in the allergic subgroup, only the lens comfort (.92, P < .001) variable is significant and appears to dominate the decision making. The overnight corneal swell evaluation revealed no significant differences between the 1-Day Acuvue and the Medalist lens. Patients wearing regular Acuvue had significantly less corneal swelling upon awakening (P = .005) and at 60 minutes after awakening (P = .003). CONCLUSIONS: The Medalist, Surevue, and Biomedics 55 lenses outperformed the 1-Day Acuvue lens in the non-allergic subgroup. In the allergic subgroup, there was no statistically significant difference between the 1-Day Acuvue lens and all other lenses tested.


Assuntos
Lentes de Contato/efeitos adversos , Edema da Córnea/etiologia , Adulto , Edema da Córnea/patologia , Equipamentos Descartáveis , Feminino , Humanos , Masculino , Estudos Prospectivos , Análise de Regressão , Inquéritos e Questionários
18.
CLAO J ; 23(1): 43-8, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9001771

RESUMO

PURPOSE: To compare the clinical performance of the Optima soft toric contact lens versus the CSI soft toric contact lens. METHODS: Twenty-one patients (five affected by allergies) were followed at 2-week intervals for 4 months in a prospective, randomized, double-masked study comparing the Optima soft toric contact lens to the CSI soft toric contact lens. RESULTS: The patients preference evaluation revealed a statistically significant preference for the CIS toric lens in 14 of 16 variables including overall lens preference (P = 0.0001). The two remaining variables, lens awareness (P = 0.07) and foreign body sensation (P = 0.06), showed a trend toward a preference for the CSI toric lens. The less sensitive symptom ranking questionnaire revealed a significance for, or a trend toward, a significant difference in three of 10 variables, all in favor of the CSI toric lens. The mean degrees of axis rotation were 3.5* for the CSI lens and 7.6* for the Optima lens (P = 0.0001). Factor analysis identified a clustering of variables around specific ranked factors. Factors related to 1) allergy status (.93); 2) visual function (.87); 3) ocular surface (.82); and 4) refractive characteristics (.71) were most significant in determining the overall clinical performance of these toric lenses. Allergic patients significantly preferred the CSI toric lens for 15 of 16 variables, whereas non-allergic patients preferred the CSI lens for seven of 16 variables. CONCLUSIONS: The patient preference, symptom ranking, and axis rotation analysis of this study revealed a superior performance by the CSI toric contact lens when compared to the Optima toric contact lens. Allergic patients revealed an even stronger and statistically significant preference for the CSI lens when compared to non-allergic patients.


Assuntos
Lentes de Contato Hidrofílicas , Erros de Refração/terapia , Adolescente , Adulto , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Erros de Refração/fisiopatologia , Análise de Regressão , Inquéritos e Questionários , Resultado do Tratamento , Acuidade Visual
19.
CLAO J ; 20(3): 159-66, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7955295

RESUMO

Sixty-three daily wear contact lens patients (42 non-allergic [66.7%] and 21 allergic [33.3%]) were randomized into three groups (CSI vs. Surevue; Focus vs. CSI; Focus vs. Surevue) and evaluated every two weeks for six months with regard to patient preferences and ranked symptom responses for 14 variables, including overall contact lens preference. Allergic patients (43.9 +/- 94.3 ng/mL) revealed significantly higher (P = .011) tear IgE levels versus non-allergic patients (15.6 +/- 25.8 ng/mL). Non-allergic patients preferred CSI over Surevue for 12 of 14 variables including overall lens preference (P < .001); CSI over Focus for 6 of 14 variables, including overall lens preference (P < .009); and Focus over Surevue for 13 of 14 variables, including overall lens preference (P < .001). In contrast, allergic patients preferred Focus over CSI for 8 of 14 variables; CSI over Surevue for 4 of 14 variables, including overall lens preference (P < .001); Focus over Surevue for 4 of 14 variables, including overall lens preference (P < .001). Surevue and Focus lenses were replaced at 4 and 8 week intervals, respectively. No significant differences in the ranked symptom responses were observed for Surevue at 4 weeks versus 2 weeks, or for Focus at 8 weeks versus 4 weeks. A regression of time versus symptom responses for non-allergic patients wearing the CSI lens revealed decreasing symptoms over time, while the allergic patients showed no significant difference.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Lentes de Contato Hidrofílicas/efeitos adversos , Oftalmopatias/etiologia , Hipersensibilidade/complicações , Adolescente , Adulto , Criança , Método Duplo-Cego , Oftalmopatias/imunologia , Oftalmopatias/fisiopatologia , Feminino , Humanos , Imunoglobulina E/análise , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Lágrimas/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...