Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Pulm Med ; 14: 24, 2014 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-24564844

RESUMO

BACKGROUND: Little is known about iron deficiency (ID) and anemia in Chronic Obstructive Pulmonary Disease (COPD). The purposes of this study were: (i) To study the prevalence and treatment of anemia and ID in patients hospitalized with an exacerbation of COPD. (ii) to study the hematological responses and degree of dyspnea before and after correction of anemia with subcutaneous Erythropoiesis Stimulating Agents (ESAs) and intravenous (IV) iron therapy, in ambulatory anemic patients with both COPD and chronic kidney disease. METHODS: (i) We examined the hospital records of all patients with an acute exacerbation of COPD (AECOPD) to assess the investigation, prevalence, and treatment of anemia and ID. (ii) We treated 12 anemic COPD outpatients with the combination of ESAs and IV-iron, given once weekly for 5 weeks. One week later we measured the hematological response and the severity of dyspnea by Visual Analogue Scale (VAS). RESULTS: (i) Anemia and iron deficiency in hospitalized COPD patients: Of 107 consecutive patients hospitalized with an AECOPD, 47 (43.9%) were found to be anemic on admission. Two (3.3%) of the 60 non-anemic patients and 18 (38.3%) of the 47 anemic patients had serum iron, percent transferrin saturation (%Tsat) and serum ferritin measured. All 18 (100%) anemic patients had ID, yet none had oral or IV iron subscribed before or during hospitalization, or at discharge. (ii) Intervention outpatient study: ID was found in 11 (91.7%) of the 12 anemic ambulatory patients. Hemoglobin (Hb), Hematocrit (Hct) and the VAS scale scores increased significantly with the ESAs and IV-iron treatment. There was a highly significant correlation between the ∆Hb and ∆VAS; rs = 0.71 p = 0.009 and between the ∆Hct and ∆VAS; rs = 0.8 p = 0.0014. CONCLUSIONS: ID is common in COPD patients but is rarely looked for or treated. Yet correction of the ID in COPD patients with ESAs and IV iron can improve the anemia, the ID, and may improve the dyspnea.


Assuntos
Anemia/tratamento farmacológico , Anemia/epidemiologia , Deficiências Nutricionais/tratamento farmacológico , Deficiências Nutricionais/epidemiologia , Hematínicos/uso terapêutico , Deficiências de Ferro , Ferro/administração & dosagem , Doença Pulmonar Obstrutiva Crônica/complicações , Idoso , Anemia/etiologia , Deficiências Nutricionais/etiologia , Feminino , Humanos , Injeções Intravenosas , Masculino , Prevalência , Estudos Retrospectivos
2.
Respiration ; 77(2): 173-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19052446

RESUMO

BACKGROUND: Vibration response imaging (VRI) is a new technology that provides a radiation-free dynamic lung image from the vibrations produced by airflow. The vibration energy from the respiratory cycle can be quantified for any lung region. This is obtained by integrating the energy profiles from 42 acoustic sensors placed on the patient's back. OBJECTIVE: The aim of this study was to evaluate whether a physician trained in interpreting acoustic images can accurately distinguish between normal and abnormal breath sound distribution in patients with pneumothoraces compared to healthy controls. METHODS: In total, 14 patients with spontaneous or iatrogenic pneumothoraces and 15 healthy volunteers were enrolled in the study. VRI recordings and physical examination were obtained in all cases. Chest radiographs (CXRs) were reviewed in patients with pneumothoraces. Dynamic images recorded during one complete respiratory cycle were analyzed for each subject. RESULTS: The VRI images of patients with pneumothoraces demonstrated a reduction in the vibration response on the affected side which correlated with the CXR. Sensitivity was 100%, specificity was 87% and positive predictive value and negative predictive value were 86 and 100%, respectively. CONCLUSIONS: This study demonstrates that VRI can be safely used to assess patients with pneumothoraces. Moreover, the analysis of breath sound distribution images obtained noninvasively can distinguish between patients with a normal chest examination from those with pneumothoraces.


Assuntos
Auscultação/instrumentação , Pneumotórax/diagnóstico , Sons Respiratórios , Adulto , Idoso , Estudos de Casos e Controles , Diagnóstico por Imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Espectrografia do Som , Vibração
3.
Respir Care ; 52(12): 1753-60, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18028567

RESUMO

OBJECTIVE: To determine whether breath sound distribution maps can differentiate between patients with pneumonia or pleural effusion versus healthy controls. METHODS: We recorded breath sounds from 20 patients conventionally diagnosed as having pleural effusion, 20 patients conventionally diagnosed as having pneumonia, and 60 healthy controls, of whom 20 served as a learning sample. All subjects were examined with a computer-based multi-sensor breath sound mapping device that records, analyzes, and displays a dynamic map of breath sound distribution. The physicians who interpreted the breath sound images were first trained in identifying common characteristics of the images from the learning sample of normals. Then the images from the 40 patients and the 40 controls were interpreted as either normal or abnormal. RESULTS: In the normal images, the left and right lung images developed synchronously and had similar size, shape, and intensity. The sensitivity and specificity of blinded differentiation between normal and abnormal images when the physician interpreter did not know the patient's workup were 82.5% and 80%, respectively. The sensitivity and specificity of blinded detection of normal and abnormal images when the interpreter did know the patient' workup were 90% and 88%, respectively. CONCLUSIONS: Computerized dynamic imaging of breath sounds is a sensitive and specific tool for distinguishing pneumonia or pleural effusion from normal lungs. The role of computerized breath sound analysis for diagnosis and monitoring of lung diseases needs further evaluation.


Assuntos
Auscultação/métodos , Derrame Pleural , Pneumonia , Sons Respiratórios , Idoso , Feminino , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Derrame Pleural/fisiopatologia , Pneumonia/fisiopatologia
4.
Inflammation ; 30(1-2): 44-51, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17372840

RESUMO

We compared exhaled breath condensate (EBC) and induced sputum (IS) for assessing inflammation in pulmonary diseases in patients with obstructive lung disease (n = 20), persistent cough >6 months (n = 20), interstitial lung disease (n = 25) and controls (n = 10). EBC was collected by suspending a Teflon perfluoroalkoxy tube installed in an ice-filled container and connected to a polypropylene test tube. IS was recovered after 20' inhalation of 3% saline with an ultrasonic nebulizer, and 300 cells were differentially counted in cytospin Giemsa-stained slides. H(2)0(2) was measured by a method based on oxidation of phenolsulfonphthalein (phenol red) mediated by horseradish peroxidases and H(2)0(2). Pulmonary function tests were performed by conventional methods. H(2)0(2) levels in EBC and % eosinophils in IS were significantly different between groups. A positive and significant correlation was found between % eosinophils in IS and the levels of H(2)0(2) in EBC for each group and for all patients combined.


Assuntos
Asma/diagnóstico , Testes Respiratórios/métodos , Tosse/diagnóstico , Eosinófilos , Peróxido de Hidrogênio/análise , Doenças Pulmonares Intersticiais/diagnóstico , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Escarro/citologia , Adulto , Idoso , Asma/sangue , Asma/fisiopatologia , Biomarcadores/análise , Tosse/sangue , Tosse/fisiopatologia , Expiração , Feminino , Humanos , Contagem de Leucócitos , Doenças Pulmonares Intersticiais/sangue , Doenças Pulmonares Intersticiais/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doença Pulmonar Obstrutiva Crônica/sangue , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Testes de Função Respiratória , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...