1.
Med Dosim ; 44(2): 136-143, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29752157

RESUMO

This study aimed to validate a novel commercially available software for correcting spatial distortion in cranial magnetic resonance (MR) images. This software has been used to assess the dosimetric impact of MR distortion in stereotactic radiosurgery (SRS) treatments of vestibular schwannomas (VSs). Five MR datasets were intentionally distorted. Each distorted MR dataset was corrected using the Cranial Distortion software, obtaining a new corrected MR dataset (MRcorr). The accuracy of the correction was quantified by calculating the target registration error (TRE) for 6 anatomical landmarks identified in the co-registered MRcorr and planning computed tomography (pCT) images. Nine VS cases were included to investigate the impact of the MR distortion in SRS plans. Each SRS plan was calculated on the pCT (1 × 1 × 1 mm3 voxel) with the target and organs at risk (OARs) delineated using the planning MR dataset. This MR dataset was then corrected (MRcorr) using the Cranial Distortion software. Geometrical agreement between the original target and the corresponding corrected target was assessed using several metrics: MacDonald criteria, mean distance to agreement (MDA), and Dice similarity coefficient (DSC). Target coverage (D99%) and maximum doses (D2%) to ipsilateral cochlea and brainstem resulting on the MRcorr dataset were compared with the original values. TRE values (0.6 mm ± 0.3 mm) and differences found in Macdonald criteria (0.3 mm ± 0.4 mm and 0.3 mm ± 0.3 mm) and MDA (0.8 mm ± 0.2 mm) were mostly within the voxel size dimension of the pCT scan (1 × 1 × 1 mm3). High similarity (DSC > 0.7) between the original and corrected targets was found. Small dose differences for the original and corrected structures were found: 0.1 Gy ± 0.1 Gy for target D99%, 0.2 Gy ± 0.3 Gy for cochlea D2%, and 0.1 Gy ± 0.1 Gy for brainstem D2%. Our study shows that Distortion Correction software can be a helpful tool to detect and adequately correct brain MR distortions. However, a negligible dosimetric impact of MR distortion has been detected in our clinical practice.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiocirurgia , Software , Humanos , Órgãos em Risco , Imagens de Fantasmas , Radiometria , Reprodutibilidade dos Testes
2.
Phys Med ; 39: 1-8, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28711183

RESUMO

PURPOSE: To investigate the feasibility of a fast protocol for radiochromic film dosimetry to verify intensity-modulated radiotherapy (IMRT) plans. METHOD AND MATERIALS: EBT3 film dosimetry was conducted in this study using the triple-channel method implemented in the cloud computing application (Radiochromic.com). We described a fast protocol for radiochromic film dosimetry to obtain measurement results within 1h. Ten IMRT plans were delivered to evaluate the feasibility of the fast protocol. The dose distribution of the verification film was derived at 15, 30, 45min using the fast protocol and also at 24h after completing the irradiation. The four dose maps obtained per plan were compared using global and local gamma index (5%/3mm) with the calculated one by the treatment planning system. Gamma passing rates obtained for 15, 30 and 45min post-exposure were compared with those obtained after 24h. RESULTS: Small differences respect to the 24h protocol were found in the gamma passing rates obtained for films digitized at 15min (global: 99.6%±0.9% vs. 99.7%±0.5%; local: 96.3%±3.4% vs. 96.3%±3.8%), at 30min (global: 99.5%±0.9% vs. 99.7%±0.5%; local: 96.5%±3.2% vs. 96.3±3.8%) and at 45min (global: 99.2%±1.5% vs. 99.7%±0.5%; local: 96.1%±3.8% vs. 96.3±3.8%). CONCLUSIONS: The fast protocol permits dosimetric results within 1h when IMRT plans are verified, with similar results as those reported by the standard 24h protocol.


Assuntos
Computação em Nuvem , Dosimetria Fotográfica/métodos , Radioterapia de Intensidade Modulada , Calibragem , Humanos , Radiometria
3.
Rep Pract Oncol Radiother ; 21(6): 500-507, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27698590

RESUMO

AIM: To investigate the viability of placing the treatment isocenter at the patient midline for breast cancer radiotherapy in order to avoid the risk of collisions during image-guided setup and treatment delivery. BACKGROUND: The use of kilovoltage orthogonal setup images has spread in last years in breast radiotherapy. There is a potential risk of an imaging system-patient collision when the isocenter is laterally placed. MATERIALS AND METHODS: Twenty IMRT plans designed by placing the isocenter within the breast volume ("plan_ref"), were retrospectively replanned by shifting the isocenter at the patient's midline ("plan_off-breast"). An integrated simultaneous boost (SIB) technique was used. Multiple metrics for the planning target volumes (PTVs) and organs at risk (OARs) were compared for both approaches using a paired t test. RESULTS: Comparing plan_ref vs. plan_off-breast, no significant differences in PTV coverage (V95%) were found (96.5% vs. 96.2%; p = 0.361 to PTVbreast; 97.0% vs. 97.0%; p = 0.977 to PTVtumor_bed). With regard to OARs, no substantial differences were observed in any analyzed metric: V5Gy (30.3% vs. 31.4%; p = 0.486), V20Gy (10.3% vs. 10.3%; p = 0.903) and mean dose (7.1 Gy vs. 7.1 Gy; p = 0.924) to the ipsilateral lung; V5Gy (11.2% vs. 10.0%; p = 0.459), V30Gy (0.7% vs. 0.6%; p = 0.251) and mean dose (2.3 Gy vs. 2.2 Gy; p = 0.400) to the heart; and average dose to the contralateral breast (0.4 Gy vs. 0.5 Gy; p = 0.107). CONCLUSIONS: The off-breast isocenter solution resulted in dosimetrically comparable plans as the reference technique, avoiding the collision risk during the treatment session.

4.
J Cancer Res Ther ; 12(2): 852-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27461663

RESUMO

AIMS: To dosimetrically compare the fixed gantry intensity modulated radiosurgery (IMRS) with dynamic conformal arc radiosurgery (DCARS) for cranial lesions. This study investigates whether IMRS can be an adequate dosimetric alternative to DCARS for cranial stereotactic radiosurgery (SRS). SUBJECTS AND METHODS: Forty-five SRS procedures for solitary brain metastasis (range: 0.44-29.18 cm 3) performed at our institution were selected for this study. Two plans were generated per patient: One IMRS plan using a multileaf collimation (MLC) of 5 mm, and one DCARS plan designed with a 3 mm micro-MLC. Dosimetric comparison metrics include the target coverage (Cov), conformity index (CI), homogeneity index (HI), gradient index (GI), and volume of the normal brain tissue receiving ≥12 Gy (V12). In addition, maximum doses to organs at risk (OAR) (brainstem, optic apparatus and cochlea) were compared for both techniques. RESULTS: Compared to DCARS, IMRS improved mean CI (IMRS: 0.81 vs. DCARS: 0.63, P < 0.001), with no significant difference in target Cov (IMRS: 0.99 vs. DCARS: 0.99, P > 0.05), HI (IMRS: 1.22 vs. DCARS: 1.24, P > 0.05), GI (IMRS: 5.44 vs. DACRS: 5.44, P > 0.05). A weak significant difference in V12 (IMRS: 4.6 cm 3 vs. 5.2 cm 3, P = 0.033) was obtained. Subgroup analysis per target volume (small: <1 cm 3, intermediate: ≤1 cm 3 and <5 cm 3 and large: ≥5 cm 3) only revealed the statistically difference for CI metric (P < 0.001). No significant differences were found for maximum dose to the OAR. CONCLUSIONS: We have shown that IMRS provides the dosimetric advantages compared with DCARS. Based on the dosimetric findings in this study, fixed gantry IMRS technique can be adopted as a standard procedure for cranial SRS when micro-MLC technology is not available on the linear accelerator.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiometria , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/diagnóstico , Humanos , Radiocirurgia/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/normas , Carga Tumoral
5.
Med Dosim ; 41(3): 199-204, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26994824

RESUMO

The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square field and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient׳s direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1mm in LR direction, and 0.7mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1mm in our CBCT-guided SRS approach.


Assuntos
Neoplasias Encefálicas/radioterapia , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias Encefálicas/patologia , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/efeitos adversos , Radioterapia Guiada por Imagem/efeitos adversos , Carga Tumoral
6.
Med Dosim ; 40(4): 279-84, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25824421

RESUMO

To evaluate the dosimetric effect of placing the isocenter away from the planning target volume (PTV) on intensity-modulated radiosurgery (IMRS) plans to treat brain lesions. A total of 15 patients who received cranial IMRS at our institution were randomly selected. Each patient was treated with an IMRS plan designed with the isocenter located at the target center (plan A). A second off-target isocenter plan (plan B) was generated for each case. In all the plans,100% of the prescription dose covered 99% of the target volume. The plans A and B were compared for the target dosage (conformity index [CI] and homogeneity index) and organs-at-risk (OAR) dose sparing. Peripheral dose falloff was compared by using the metrics volume of normal brain receiving more than 12-Gy dose (V12) and CI at the level of the 50% of the prescription dose (CI 50%). The values found for each metric (plan B vs plan A) were (mean ± standard deviation [SD]) as follows-CI: 1.28 ± 0.15 vs 1.28 ± 0.15, p = 0.978; homogeneity index (HI): 1.29 ± 0.14 vs 1.34 ± 0.17, p = 0.079; maximum dose to the brainstem: 2.95 ± 2.11 vs 2.89 ± 1.88Gy, p = 0.813; maximum dose to the optical pathway: 2.65 ± 4.18 vs 2.44 ± 4.03Gy, p = 0.195; and maximum dose to the eye lens: 0.33 ± 0.73 vs 0.33 ± 0.53Gy, p = 0.970. The values of the peripheral dose falloff were (plan B vs plan A) as follows-V12: 5.98 ± 4.95 vs 6.06 ± 4.92cm(3), p = 0.622, and CI 50%: 6.08 ± 2.77 vs 6.28 ± 3.01, p = 0.119. The off-target isocenter solution resulted in dosimetrically comparable plans as the center-target isocenter technique, by avoiding the risk of gantry-couch collision during the cone beam computed tomography (CBCT) acquisition.


Assuntos
Encéfalo/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador , Estudos de Viabilidade , Humanos
7.
J Appl Clin Med Phys ; 15(2): 4665, 2014 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-24710455

RESUMO

In the present study, we describe a method based on the analysis of the dynamic MLC log files (DynaLog) generated by the controller of a Varian linear accelerator in order to perform patient-specific IMRT QA. The DynaLog files of a Varian Millennium MLC, recorded during an IMRT treatment, can be processed using a MATLAB-based code in order to generate the actual fluence for each beam and so recalculate the actual patient dose distribution using the Eclipse treatment planning system. The accuracy of the DynaLog-based dose reconstruction procedure was assessed by introducing ten intended errors to perturb the fluence of the beams of a reference plan such that ten subsequent erroneous plans were generated. In-phantom measurements with an ionization chamber (ion chamber) and planar dose measurements using an EPID system were performed to investigate the correlation between the measured dose changes and the expected ones detected by the reconstructed plans for the ten intended erroneous cases. Moreover, the method was applied to 20 cases of clinical plans for different locations (prostate, lung, breast, and head and neck). A dose-volume histogram (DVH) metric was used to evaluate the impact of the delivery errors in terms of dose to the patient. The ionometric measurements revealed a significant positive correlation (R² = 0.9993) between the variations of the dose induced in the erroneous plans with respect to the reference plan and the corresponding changes indicated by the DynaLog-based reconstructed plans. The EPID measurements showed that the accuracy of the DynaLog-based method to reconstruct the beam fluence was comparable with the dosimetric resolution of the portal dosimetry used in this work (3%/3 mm). The DynaLog-based reconstruction method described in this study is a suitable tool to perform a patient-specific IMRT QA. This method allows us to perform patient-specific IMRT QA by evaluating the result based on the DVH metric of the planning CT image (patient DVH-based IMRT QA).


Assuntos
Neoplasias/radioterapia , Controle de Qualidade , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Anisotropia , Feminino , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Aceleradores de Partículas , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Doses de Radiação , Radiometria , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Software
8.
Med Dosim ; 39(2): 129-33, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24342166

RESUMO

The aim of this study is to assess the accuracy of a convolution-based algorithm (anisotropic analytical algorithm [AAA]) implemented in the Eclipse planning system for intensity-modulated radiosurgery (IMRS) planning of small cranial targets by using a 5-mm leaf-width multileaf collimator (MLC). Overall, 24 patient-based IMRS plans for cranial lesions of variable size (0.3 to 15.1cc) were planned (Eclipse, AAA, version 10.0.28) using fixed field-based IMRS produced by a Varian linear accelerator equipped with a 120 MLC (5-mm width on central leaves). Plan accuracy was evaluated according to phantom-based measurements performed with radiochromic film (EBT2, ISP, Wayne, NJ). Film 2D dose distributions were performed with the FilmQA Pro software (version 2011, Ashland, OH) by using the triple-channel dosimetry method. Comparison between computed and measured 2D dose distributions was performed using the gamma method (3%/1mm). Performance of the MLC was checked by inspection of the DynaLog files created by the linear accelerator during the delivery of each dynamic field. The absolute difference between the calculated and measured isocenter doses for all the IMRS plans was 2.5% ± 2.1%. The gamma evaluation method resulted in high average passing rates of 98.9% ± 1.4% (red channel) and 98.9% ± 1.5% (blue and green channels). DynaLog file analysis revealed a maximum root mean square error of 0.46mm. According to our results, we conclude that the Eclipse/AAA algorithm provides accurate cranial IMRS dose distributions that may be accurately delivered by a Varian linac equipped with a Millennium 120 MLC.


Assuntos
Encefalopatias/cirurgia , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Humanos
9.
Med Dosim ; 38(3): 291-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23540494

RESUMO

To introduce an approach for online adaptive replanning (i.e., dose-guided radiosurgery) in frameless stereotactic radiosurgery, when a 6-dimensional (6D) robotic couch is not available in the linear accelerator (linac). Cranial radiosurgical treatments are planned in our department using intensity-modulated technique. Patients are immobilized using thermoplastic mask. A cone-beam computed tomography (CBCT) scan is acquired after the initial laser-based patient setup (CBCTsetup). The online adaptive replanning procedure we propose consists of a 6D registration-based mapping of the reference plan onto actual CBCTsetup, followed by a reoptimization of the beam fluences ("6D plan") to achieve similar dosage as originally was intended, while the patient is lying in the linac couch and the original beam arrangement is kept. The goodness of the online adaptive method proposed was retrospectively analyzed for 16 patients with 35 targets treated with CBCT-based frameless intensity modulated technique. Simulation of reference plan onto actual CBCTsetup, according to the 4 degrees of freedom, supported by linac couch was also generated for each case (4D plan). Target coverage (D99%) and conformity index values of 6D and 4D plans were compared with the corresponding values of the reference plans. Although the 4D-based approach does not always assure the target coverage (D99% between 72% and 103%), the proposed online adaptive method gave a perfect coverage in all cases analyzed as well as a similar conformity index value as was planned. Dose-guided radiosurgery approach is effective to assure the dose coverage and conformity of an intracranial target volume, avoiding resetting the patient inside the mask in a "trial and error" way so as to remove the pitch and roll errors when a robotic table is not available.


Assuntos
Neoplasias Encefálicas/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada de Feixe Cônico , Estudos de Viabilidade , Humanos , Sistemas On-Line , Dosagem Radioterapêutica , Estudos Retrospectivos