1.
Int J Pharm ; 344(1-2): 150-3, 2007 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-17669608

RESUMO

Local fungal infections with Candida, Fusarium, Curvularia and Aspergillus can lead to serious ulceration of the cornea and must be treated rapidly. The current treatment consists of 0.15% (w/v) amphotericin B eye drops prepared from Fungizone, containing deoxycholate, irritant for the cornea, which reduces patient compliance. Eye drops based on liposomal amphotericin B (AmBisome would be a convenient alternative; however, according to the manufacturer's instructions, AmBisome can only be kept refrigerated for 1 week after reconstitution. A longer shelf-life at ambient temperature would be preferable for a preparation made in a hospital pharmacy and delivered to patients. Thus, the possibility of storing an ophthalmic preparation of 0.5% (w/v) liposomal amphotericin B after reconstitution was investigated. After 6 months at room temperature or at +2-8 degrees C, the hydrodynamic diameter measured by quasi-elastic light scattering remained constant at 108 +/- 30 nm with a polydispersity index lower than 0.15. Amphotericin B content, checked by a validated HPLC method, was maintained between 94 and 107%. Amphotericin B and soy phosphatidylcholine proportions remained constant, indicating that the liposomes remained intact and retained the drug. These results show the feasibility of an ophthalmic preparation based on liposomal amphotericin B developed in hospital pharmacies.


Assuntos
Anfotericina B/química , Antifúngicos/química , Administração Tópica , Anfotericina B/administração & dosagem , Antifúngicos/administração & dosagem , Cromatografia Líquida de Alta Pressão , Úlcera da Córnea/tratamento farmacológico , Composição de Medicamentos , Estabilidade de Medicamentos , Armazenamento de Medicamentos , Infecções Oculares Fúngicas/tratamento farmacológico , Humanos , Luz , Soluções Oftálmicas , Espalhamento de Radiação , Temperatura
2.
Transplant Proc ; 36(5): 1317-20, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15251322

RESUMO

Cyclosporine (CyA) has a narrow therapeutic index. Determination of CyA concentrations correlate with rejection or adverse effects like nephropathy. Cyclosporine is assayed based on either chromatographic or many different immunoenzymologic techniques. The investigators evaluated a new heterogeneous immunoassay of CyA on RxL Dimension. The pretreatment step is automatically performed in the apparatus. Linearity, intra- and interday precision, limit of quantification, dilutions, and stability of the equipment were compared with the EMIT method for patient determinations. The heterogeneous immunoassay showed a good linearity between 0 and 500 ng/mL, and intra- and inter-day precision with a coefficient of variation below 9.2%. The investigators observed reproducible and accurate dilutions of high concentrations (500 to 2000 ng/mL). The correlation with the EMIT technique was valid: ACMIA = 0.964 EMIT + 0.156 (r = .96) for different types of transplant (n = 116). Finally, this new system improves the determination of CyA concentrations.


Assuntos
Transplante de Medula Óssea/imunologia , Ciclosporina/sangue , Transplante de Coração/imunologia , Transplante de Rim/imunologia , Transplante de Fígado/imunologia , Monitoramento de Medicamentos/métodos , Técnica de Imunoensaio Enzimático de Multiplicação , Humanos , Imunoensaio/métodos , Imunossupressores/sangue , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Ann Biol Clin (Paris) ; 61(6): 713-8, 2003.
Artigo em Francês | MEDLINE | ID: mdl-14711615

RESUMO

We propose an evaluation of a new heterogeneous immunoassay of cyclosporin on RXL HM Dimension (Dade Behring) for therapeutic cyclosporin monitoring in whole-blood patients transplant. The pretreatment step is performed automatically into the apparatus while it is a manual step with EMIT. Linearity, intra- and inter-day precision, limit of quantification, precision and accuracy of dilution steps and stability into the equipment were studied. We realized the comparison between ACMIA and EMIT methods on whole-blood patients transplant recipients. Heterogeneous immunoassay showed a good linearity between 0 and 500 ng/mL, intra- and inter-day precision with coefficient of variation inferior to 7.2%. We observed reproducible and accurate dilutions of high concentrations (500 to 2,000 ng/mL). The correlation with EMIT technique was correct for different type of transplant (n=55).


Assuntos
Ciclosporina/sangue , Imunoensaio , Humanos , Imunoensaio/métodos
4.
Anal Chem ; 73(13): 3083-8, 2001 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-11467557

RESUMO

The utility of packed-column supercritical, subcritical, and enhanced fluidity liquid chromatographies (pcSFC) for high-throughput applications has increased during the past few years. In contrast to traditional reversed-phase liquid chromatography, the addition of a volatile component to the mobile phase, such as CO2, produces a lower mobile-phase viscosity. This allows the use of higher flow rates which can translate into faster analysis times. In addition, the resulting mobile phase is considerably more volatile than the aqueous-based mobile phases that are typically used with LC-MS, allowing the entire effluent to be directed into the MS interface. High-throughput bioanalytical quantitation using pcSFC-MS/MS for pharmacokinetics applications is demonstrated in this report using dextromethorphan as a model compound. Plasma samples were prepared by automated liquid/liquid extraction in the 96-well format prior to pcSFC-MS/MS analysis. Three days of validation data are provided along with study sample data from a patient dosed with commercially available Vicks 44. Using pcSFC and MS/MS, dextromethorphan was quantified in 96-well plates at a rate of approximately 10 min/plate with average intraday accuracy of 9% or better. Daily relative standard deviations (RSDs) were less than 10% for the 2.21 and 14.8 ng/mL quality control (QC) samples, while the RSDs were less than 15% at the 0.554 ng/mL QC level.


Assuntos
Antitussígenos/sangue , Cromatografia Líquida/métodos , Dextrometorfano/sangue , Espectrometria de Massas/métodos , Antitussígenos/farmacocinética , Dextrometorfano/farmacocinética , Humanos , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Bioorg Med Chem Lett ; 11(9): 1149-52, 2001 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-11354364

RESUMO

An effort to identify novel inhibitors of peptidoglycan synthesis with antibacterial activity resulted in the discovery of a series of biaryl urea-based antibacterial agents through isolation of a by-product from a mixture-based combinatorial library of semi-carbazones and subsequent parallel synthesis efforts. The compounds were shown to possess broad spectrum antibacterial activity against gram-positive drug resistant pathogens, and showed apparent specificity for disruption of the bacterial cell wall biosynthesis pathway.


Assuntos
Antibacterianos/síntese química , Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Hidrazinas/síntese química , Hidrazinas/farmacologia , Ureia/análogos & derivados , Ureia/química , Ureia/farmacologia , Bactérias/crescimento & desenvolvimento , Bactérias/ultraestrutura , Parede Celular/efeitos dos fármacos , Fenômenos Químicos , Físico-Química , Cromatografia Líquida de Alta Pressão , Técnicas de Química Combinatória , Espectrometria de Massas , Testes de Sensibilidade Microbiana
6.
Anal Chem ; 73(2): 247-52, 2001 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-11199973

RESUMO

Improvements to the design and operation of a Gilson 215 multiprobe liquid-handling system have resulted in a significant increase in the throughput for flow injection molecular weight characterization of combinatorial chemistry libraries. The rapid injection sequence, and subsequent increased sample throughput, is effected by directing the entire mobile-phase flow through each of the injection loops sequentially while isolating or "dead-ending" the remaining nonactive loops. This mode of operation was accomplished by incorporating column-switching valves prior to and following the set of eight parallel injectors. Analysis rates are achieved without sacrificing the integrity of the flow injection peak profile as baseline resolution is maintained for all samples. Using this system, the total analysis time for a 96-well microtiter plate has been reduced to approximately 5 min.

7.
Curr Opin Drug Discov Devel ; 4(6): 729-35, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11899612

RESUMO

The evolution of high-throughput drug discovery is readily apparent as the pharmaceutical industry continues to stress the rapid progression of new chemical entities and biological agents through drug discovery and development pipelines. Mass spectrometry and high performance liquid chromatography-mass spectrometry have played an instrumental role in the support and advancement of all facets of high-throughput drug discovery. The introduction of new instrumentation has extended the breadth of mass spectrometric-based capabilities from the characterization of high-throughput organic synthesis products to early adsorption, distribution, metabolism and excretion profiling. Additionally, advances in the capacity and throughput of mass spectrometry systems have concurrently led to the introduction of data management tools to address automated data reduction, archival and mining, as well as analytical data integration to chemical and biological databases.


Assuntos
Espectrometria de Massas , Preparações Farmacêuticas/análise , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas/instrumentação , Peptídeos/química , Proteínas/química , Software
8.
J Am Soc Mass Spectrom ; 7(2): 150-6, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24203235

RESUMO

A nano electrospray (NanoES)/ion trap combination was developed to take advantage of the long spraying time of the NanoES source (Wilm, M. S., Mann, M. Int. J. Mass Spectrom. Ion Processes 1994, 136, 167-180) for extensive experiments on the ion trap. The low flow rate associated with the NanoES allows for optimization of experimental conditions and data acquisition for more than 30 min with 1 µL of solution. Thus, even time-consuming experiments, such as multiple fragmentation steps or the sequencing of many components in a mixture, can be performed with very small volumes of sample. Stored waveform inverse Fourier transformation (SWIFT) signals were used during the injection period to accumulate ions of low intensity and to improve the dynamic range of the quadrupole ion trap. To sequence peptides, a combination of nozzle-skimmer fragmentation, SWIFT accumulation of a single fragment to high intensity, and a second fragmentation step was employed to obtain complete sequence information. Unseparated peptide mixtures were infused and weak portions of the spectrum were enhanced by using the SWIFT method, followed by fragmentation of various accumulated peptide ions.

9.
J Biol Chem ; 269(34): 21473-9, 1994 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-8063781

RESUMO

A series of novel hemes with modifications of the isoprenyl side chain has been detected in archaea. Heme A(S) was isolated from cytochrome oxidases of the thermoacidophilic archaeon, Sulfolobus acidocaldarius. Heme A(S) has the same spectroscopic features as heme A but has a hydroxyethylgeranylgeranyl side chain instead of the hydroxyethylfarnesyl group. This variant is also present in other archaeal oxidases as well as in the cytochrome oxidases of a thermophilic eubacterium. Other archaea (Thermoplasma, Pyrobaculum) were also shown to have cytochrome oxidases. From these organisms, three novel prenylated heme variants (called OT, OP1, and OP2) were isolated. They are structurally related to heme O; OP2 has a hydroxyethylgeranylgeranyl instead of the hydroxyethylfarnesyl side chain. In OP1 and OT, the hydroxyethylprenyl group is altered to ethenylprenyl by elimination of a water molecule. Most probably, the novel hemes are cofactors binding to the binuclear reaction centers of archaeal cytochrome oxidases.


Assuntos
Archaea/química , Complexo IV da Cadeia de Transporte de Elétrons/química , Heme/análogos & derivados , Terpenos/química , Archaea/enzimologia , Bactérias/química , Cromatografia Líquida de Alta Pressão , Diterpenos/química , Farneseno Álcool/análogos & derivados , Heme/química , Espectrometria de Massas , Membranas/química , Espectrofotometria , Sulfolobus acidocaldarius/química , Sulfolobus acidocaldarius/enzimologia , Thermoplasma/química , Thermoplasma/enzimologia
10.
Dev Biol ; 163(2): 440-6, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7911112

RESUMO

Animal development depends on cell communication by signals. We have investigated the role of signals and of signal transduction in the development of the marine hydroid Hydractinia echinata. The larvae undergo metamorphosis in response to a chemical signal provided by environmental bacteria. Metamorphosis can be induced by a variety of different compounds interfering with biochemical signal transduction pathways. Sectioned posterior parts cannot be induced by most compounds known to induce whole larvae to metamorphose. We identified a novel peptide, pGlu-Gln-Pro-Gly-Leu-TrpNH2 ("metamorphosin A"), which induces isolated posterior parts to undergo metamorphosis and hence reactivates pattern formation, cell proliferation, cell differentiation, and morphogenesis. We suggest this peptide to be part of an internal signaling system involved in control of metamorphosis.


Assuntos
Cnidários/crescimento & desenvolvimento , Oligopeptídeos/fisiologia , Peptídeos/fisiologia , Sequência de Aminoácidos , Animais , Larva , Metamorfose Biológica , Dados de Sequência Molecular , Morfogênese , Ácido Pirrolidonocarboxílico/análogos & derivados , Transdução de Sinais
11.
Rapid Commun Mass Spectrom ; 7(8): 738-43, 1993 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8374164

RESUMO

[M + H + 16]+ ions were observed in the electrospray ionization mass spectra of several synthetic and naturally occurring peptides. Initial results have shown that the appearance of the modification is dependent on the field strength at the electrospray needle and the flow rate of the solution passing through the capillary. Mass spectrometric experiments on peptides showing the + 16 Da modification attributed the change to the selective oxidation of either a methionyl, tryptophanyl, or tyrosyl residue present in the peptide. These results were further confirmed by tandem mass spectrometry experiments on peptides with a methionyl residue at either the N- or C-terminus, or within the peptide chain. This effect can occur under normal operating conditions and therefore care must be taken in the analysis of samples containing these oxidizable residues. Conversely, the selectivity of the oxidative process may be used to enhance the information obtained from the mass spectrometric analysis. For example, we show results for the analysis of a tryptic digest of the protein myoglobin where the occurrence of the [M + H + 16]+ ion is used, along with the molecular weight data, to correctly identify the trypic fragment.


Assuntos
Peptídeos/análise , Sequência de Aminoácidos , Espectrometria de Massas , Dados de Sequência Molecular , Oxirredução , Peptídeos/química