Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 38(1): 89-100, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37863862

RESUMO

PURPOSE: This systematic review of randomized-controlled trials (RCTs) with meta-analyses aimed to compare the effects on intraoperative arterial oxygen tension to inspired oxygen fraction ratio (PaO2/FiO2), exerted by positive end-expiratory pressure (PEEP) individualized trough electrical impedance tomography (EIT) or esophageal pressure (Pes) assessment (intervention) vs. PEEP not tailored on EIT or Pes (control), in patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach. METHODS: PUBMED®, EMBASE®, and Cochrane Controlled Clinical trials register were searched for observational studies and RCTs from inception to the end of August 2022. Inclusion criteria were: RCTs comparing PEEP titrated on EIT/Pes assessment vs. PEEP not individualized on EIT/Pes and reporting intraoperative PaO2/FiO2. Two authors independently extracted data from the enrolled investigations. Data are reported as mean difference and 95% confidence interval (CI). RESULTS: Six RCTs were included for a total of 240 patients undergoing general anesthesia for surgery, of whom 117 subjects in the intervention group and 123 subjects in the control group. The intraoperative mean PaO2/FiO2 was 69.6 (95%CI 32.-106.4 ) mmHg higher in the intervention group as compared with the control group with 81.4% between-study heterogeneity (p < 0.01). However, at meta-regression, the between-study heterogeneity diminished to 44.96% when data were moderated for body mass index (estimate 3.45, 95%CI 0.78-6.11, p = 0.011). CONCLUSIONS: In patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach, PEEP personalized by EIT or Pes allowed the achievement of a better intraoperative oxygenation compared to PEEP not individualized through EIT or Pes. PROSPERO REGISTRATION NUMBER: CRD 42021218306, 30/01/2023.


Assuntos
Respiração com Pressão Positiva , Tomografia Computadorizada por Raios X , Humanos , Impedância Elétrica , Ensaios Clínicos Controlados Aleatórios como Assunto , Respiração com Pressão Positiva/métodos , Oxigênio
2.
Ultrasound J ; 15(1): 3, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36693978

RESUMO

BACKGROUND: This single-center preliminary prospective observational study used bedside ultrasound to assess the lung aeration modifications induced by recruitment maneuver and pronation in intubated patients with acute respiratory disease syndrome (ARDS) related to coronavirus 2019 disease (COVID-19). All adult intubated COVID-19 patients suitable for pronation were screened. After enrollment, patients underwent 1 h in a volume-controlled mode in supine position (baseline) followed by a 35-cmH2O-recruitment maneuver of 2 min (recruitment). Final step involved volume-controlled mode in prone position set as at baseline (pronation). At the end of the first two steps and 1 h after pronation, a lung ultrasound was performed, and global and regional lung ultrasound score (LUS) were analyzed. Data sets are presented as a median and 25th-75th percentile. RESULTS: From January to May 2022, 20 patients were included and analyzed. Global LUS reduced from 26.5 (23.5-30.0) at baseline to 21.5 (18.0-23.3) and 23.0 (21.0-26.3) at recruitment (p < 0.001) and pronation (p = 0.004). In the anterior lung regions, the regional LUS were 1.8 (1.1-2.0) following recruitment and 2.0 (1.6-2.2) in the supine (p = 0.008) and 2.0 (1.8-2.3) in prone position (p = 0.023). Regional LUS diminished from 2.3 (2.0-2.5) in supine to 2.0 (1.8-2.0) with recruitment in the lateral lung zones (p = 0.036). Finally, in the posterior lung units, regional LUS improved from 2.5 (2.3-2.8) in supine to 2.3 (1.8-2.5) through recruitment (p = 0.003) and 1.8 (1.3-2.2) with pronation (p < 0.0001). CONCLUSIONS: In our investigation, recruitment maneuver and prone positioning demonstrated an enhancement in lung aeration when compared to supine position, as assessed by bedside lung ultrasound. TRIAL REGISTRATION: www. CLINICALTRIALS: gov , Number NCT05209477, prospectively registered and released on 01/26/2022.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...