Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 29(20): 32404-32411, 2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34615312

RESUMO

We developed an optically synchronized highly stable frequency-doubled Nd:YAG laser with sub-nanosecond pulse duration. The 1064 nm seed pulses generated by soliton self-frequency shift in a photonic crystal fiber from Ti:sapphire oscillator pulses were stabilized by controlling input pulse polarization. The seed pulses were amplified to 200 mJ by diode-pumped amplifiers with a high stability of only <0.2% (rms). With an external LBO doubler, the system generated 330 ps green pulse energy of 130 mJ at 532 nm with a conversion efficiency of 65%. The pulse duration was further extended to 490 ps by adjusting Nd:YAG crystal temperature. To the best of our knowledge, these results present a longer pulse duration with higher stability than previous Nd:YAG lasers with sub-nanosecond optical synchronization.

2.
Rev Sci Instrum ; 92(3): 033306, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820038

RESUMO

This paper reports on the absolute response of a Fuji BAS-TR image plate to relatively low-energy protons (<0.2 MeV) and carbon ions (<1 MeV) accelerated by a 10-TW-class compact high-intensity laser system. A Thomson parabola spectrometer was used to discriminate between different ion species while dispersing the ions according to their kinetic energy. Ion parabolic traces were recorded using an image plate detector overlaid with a slotted CR-39 solid-state detector. The obtained response function for the protons was reasonably extrapolated from previously reported higher-ion-energy response functions. Conversely, the obtained response function for carbon ions was one order of magnitude higher than the value extrapolated from previously reported higher-ion-energy response functions. In a previous study, it was determined that if the stopping range of carbon ions is comparable to or smaller than the grain size of the phosphor, then some ions will provide all their energy to the binder resin rather than the phosphor. As a result, it is believed that the imaging plate response will be reduced. Our results show good agreement with the empirical formula of Lelasseux et al., which does not consider photo-stimulated luminescence (PSL) reduction due to the urethane resin. It was shown that the PSL reduction due to the deactivation of the urethane resin is smaller than that previously predicted.

3.
Rev Sci Instrum ; 91(5): 053305, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32486709

RESUMO

This article reports the development of a compact Thomson parabola spectrometer for laser-accelerated ions that can measure angular distribution with a high energy resolution and has a variable measurable energy range. The angular-resolved energy spectra for different ion species can be measured in a single shot, and the sampling angle can be selected from outside the vacuum region. The electric and magnetic fields are applied to the ion dispersion by using a permanent magnetic circuit and annulus sector-shaped electrodes with a wedge configuration. The compact magnetic circuit consists of permanent magnets, fixed yokes, and movable yokes. The magnetic flux is intentionally leaked to the movable yokes, allowing the magnetic field to be adjusted from 53 mT to 259 mT. The annulus sector-shaped electrodes with a wedge configuration provide better trace separation for high-energy ions, retain the lower-energy part of the ion signal, and subject ions passing through all pinholes to an equivalent Lorentz force. The magnetic and electric fields are designed for measuring protons and carbon ions with an energy range of 0.1-5 MeV. The spectrometer allows for the adjustment of the observable energy range afterward according to the parameters of the accelerated ion.

4.
Opt Lett ; 43(11): 2595-2598, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29856438

RESUMO

We report the generation of 63 J of broadband pulse energies at 0.1 Hz from the J-KAREN-P laser, which is based on an OPCPA/Ti:sapphire hybrid architecture. Pulse compression down to 30 fs indicates a peak power of over 1 PW. High temporal contrast of 1012 prior to the main pulse has been demonstrated with 10 J output energy. High intensities of 1022 W/cm2 on target by focusing a 0.3 PW laser with an f/1.3 off-axis parabolic mirror have been achieved. Fundamental processes of laser matter interaction at over 1022 W/cm2 intensities belong to a new branch of science that will be the principal research task of our infrastructure.

5.
Opt Express ; 25(17): 20486-20501, 2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-29041729

RESUMO

J-KAREN-P is a high-power laser facility aiming at the highest beam quality and irradiance for performing state-of-the art experiments at the frontier of modern science. Here we approached the physical limits of the beam quality: diffraction limit of the focal spot and bandwidth limit of the pulse shape, removing the chromatic aberration, angular chirp, wavefront and spectral phase distortions. We performed accurate measurements of the spot and peak fluence after an f/1.3 off-axis parabolic mirror under the full amplification at the power of 0.3 PW attenuated with ten high-quality wedges, resulting in the irradiance of ~1022 W/cm2 and the Strehl ratio of ~0.5.

6.
Rev Sci Instrum ; 87(6): 063307, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27370447

RESUMO

We propose a simple and effective synchronization technique between a reference electrical oscillator and a mode-locked laser for a narrowband picosecond Laser-Compton scattering γ-ray source by using a commercial-based 1-chip frequency synthesizer, which is widely used in radio communication. The mode-locked laser has been successfully synchronized in time with a jitter of 180 fs RMS for 10 Hz-100 kHz bandwidth. A good stability of 640 µHz at 80 MHz repetition rate for 10 h operation has also been confirmed. We discuss in detail the design and performance of this technique (in terms of timing jitter, stability, and validity).

7.
Phys Rev E ; 94(6-1): 063205, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28085322

RESUMO

Interaction of relativistically intense axisymmetrically polarized (radially or azimuthally polarized) laser pulses (RIAPLP) with underdense plasma is shown experimentally and theoretically to be essentially different from the interaction of conventional Gaussian pulses. The difference is clearly observed in distinct spectra of the side-scattered laser light for the RIAPLP and Gaussian pulses, as well as in the appearance of a spatially localized strong side emission of second harmonic of the laser pulse in the case of RIAPLP. According to our analysis based on three-dimensional particle-in-cell simulations, this is a result of instability in the propagation of RIAPLP in uniform underdense plasma.

8.
Opt Express ; 23(11): 15057-64, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26072862

RESUMO

We have developed a 1 kHz repetition picosecond laser system dedicated for intense terahertz (THz) pulse generation. The system comprises a chirped pulse amplification laser equipped with a Yb:YAG thin-disk amplifier. At room temperature, the Yb:YAG thin-disk regenerative amplifier provides pulses having energy of over 10 mJ and spectral bandwidth of 1.2 nm. The pulse duration achieved after passage through a diffraction grating pair compressor was 1.3 ps. By employing this picosecond laser as a pump source, THz pulses having a peak frequency of 0.3 THz and 4 µJ of energy were generated by means of optical rectification in an Mg-doped LiNbO3 crystal.

9.
Opt Express ; 22(6): 6613-9, 2014 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-24664010

RESUMO

Nowadays, generation of energy-tunable, monochromatic γ-rays is needed to establish a nondestructive assay method of nuclear fuel materials. The γ-rays are generated by collision of laser photons stored in a cavity and relativistic electrons. We propose a configuration of an enhancement cavity capable of performing polarization control fabricated by a combination of a four-mirror ring cavity with a small spot inside a cavity and a three-mirror of reflective optics as an image inverter for polarization-selectable γ-rays. The image inverter introduces a phase shift of specific polarization which can be used to generate an error signal to lock an optical cavity at a resonance condition.

10.
Opt Lett ; 37(16): 3363-5, 2012 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23381258

RESUMO

We demonstrate the temporal contrast enhancement in a petawatt-class Ti:sapphire chirped-pulse amplification (CPA) laser system. An extra saturable absorber, introduced downstream after a low-gain optical parametric chirped-pulse amplification (OPCPA) preamplifier, has improved the temporal contrast in the system to 1.4×10(12) on the subnanosecond time scale at 70 TW power level. We have achieved 28 J of uncompressed broadband output energy with this system, indicating the potential for reaching peak powers near 600 TW.

11.
Opt Lett ; 35(10): 1497-9, 2010 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-20479787

RESUMO

Optical parametric chirped-pulse amplification (OPCPA) operation with low gain by seeding with high-energy, clean pulses is shown to significantly improve the contrast to better than 10(-10) to 10(-11) in a high-intensity Ti:sapphire laser system that is based on chirped-pulse amplification. In addition to the high-contrast broadband, high-energy output from the final amplifier is achieved with a flat-topped spatial profile of filling factor near 77%. This is the result of pump beam spatial profile homogenization with diffractive optical elements. Final pulse energies exceed 30 J, indicating capability for reaching peak powers in excess of 500 TW.


Assuntos
Óxido de Alumínio , Lasers , Titânio , Fatores de Tempo
12.
Appl Opt ; 49(11): 2105-15, 2010 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-20390013

RESUMO

We have developed a femtosecond high-intensity laser system that combines both Ti:sapphire chirped-pulse amplification (CPA) and optical parametric CPA (OPCPA) techniques and produces more than 30 J broadband output energy, indicating the potential for achieving peak powers in excess of 500 TW. With a cleaned high-energy seeded OPCPA preamplifier as a front end in the system, for the compressed pulse without pumping the final amplifier, we found that the temporal contrast in this system exceeds 10(10) on the subnanosecond time scales, and is near 10(12) on the nanosecond time scale prior to the peak of the main femtosecond pulse. Using diffractive optical elements for beam homogenization of a 100 J level high-energy Nd:glass green pump laser in a Ti:sapphire final amplifier, we have successfully generated broadband high-energy output with a near-perfect top-hat-like intensity distribution.


Assuntos
Lasers , Óptica e Fotônica , Óxido de Alumínio/química , Amplificadores Eletrônicos , Desenho de Equipamento , Risco , Processamento de Sinais Assistido por Computador/instrumentação , Fatores de Tempo , Titânio/química
13.
Opt Lett ; 33(7): 645-7, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18382504

RESUMO

We report a high-contrast, high-intensity Ti:sapphire chirped-pulse amplification system that incorporates a nonlinear preamplifier based on optical parametric chirped-pulse amplification (OPCPA). By cooling the Ti:sapphire crystal in the final amplifier down to 77 K, the chirped-pulses are amplified to 2.9 J at a 10 Hz repetition rate without a thermal lensing effect. Pulse compression down to 19 fs duration obtained after amplification indicates a peak power of 80 TW. With the OPCPA, the temporal contrast is significantly improved to better than 7x10(-9) in a few picoseconds interval prior to the main laser pulse.

14.
Opt Lett ; 32(16): 2315-7, 2007 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-17700770

RESUMO

We describe a compact, reliable, high-power, and high-contrast noncollinear optical parametric chirped-pulse amplifier system. With a broadband Ti:sapphire oscillator and grating-based stretching and compression, the chirped pulses are amplified from 0.1 nJ to 122 mJ in type I beta-barium borate optical parametric chirped-pulse amplifiers with a total gain of over 10(9) at 10 Hz repetition rate. Pulse compression down to 19-fs duration achieved after amplification indicates a peak power of 3.2 TW at an average power of 0.62 W. The prepulse contrast is measured to be less than 10(-8) on picosecond time scales.

15.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(1 Pt 2): 016402, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11800785

RESUMO

The second-harmonic emission generated by the spatially asymmetric quivering electrons caused by the ponderomotive force was studied. The intensity of the second harmonic was proportional to the focused intensity of the pump pulse with the power of 1.8. This intensity dependence can be explained by the relativistic effect of the quivering electrons.

SELEÇÃO DE REFERÊNCIAS