Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circ J ; 84(7): 1112-1117, 2020 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-32418957

RESUMO

BACKGROUND: Central venous pressure (CVP) is measured to assess intravascular fluid status. Although the clinical gold standard for evaluating CVP is invasive measurement using catheterization, the use of catheterization is limited in a clinical setting because of its invasiveness. We developed novel non-invasive technique, enclosed-zone (ezCVPTM) measurement for estimating CVP. The purpose of this study was to assess the feasibility of ezCVP and the relationship between ezCVP and CVP measured by a catheter.Methods and Results:We conducted 291 measurements in 97 patients. Linear regression analysis revealed that ezCVP was significantly correlated with CVP (r=0.65, P<0.0001). The Bland-Altman analysis showed that ezCVP had an underestimation bias of -2.5 mmHg with 95% limits of agreement of -14.1 mmHg and 9.6 mmHg for CVP (P<0.0001). The areas under the curves of receiver operating curve with ezCVP to detect the CVP ≥12 cmH2O (8.8 mmHg) and CVP >10 mmHg were 0.81 or 0.88, respectively. The sensitivity, specificity and positive likelihood ratio of ezCVP for the CVP ≥8.8 mmHg and CVP >10 mmHg were 0.59, 0.96 and 14.8 with a cut-off value of 11.9 and 0.79, 0.97 and 26.3 with a cut-off value of 12.7. CONCLUSIONS: These findings suggest that ezCVP measurement is feasible and useful for assessing CVP.


Assuntos
Determinação da Pressão Arterial , Doenças Cardiovasculares/diagnóstico , Pressão Venosa Central , Extremidade Superior/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/fisiopatologia , Cateterismo Venoso Central , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oscilometria , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
J Feline Med Surg ; 22(6): 557-563, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31313970

RESUMO

OBJECTIVES: The aim of this study was to investigate the antiemetic, behavioural and physiological effects of oral maropitant treatment before the administration of brimonidine ophthalmic solution in healthy cats. METHODS: Five cats received oral maropitant 8 mg or no treatment (control) 18 h before the administration of one drop of brimonidine solution in both eyes. Each cat was administered each of the two treatments, with a washout period of 1 week. The incidence of emesis, retching, sialorrhoea and lip-licking after brimonidine administration was recorded, while behavioural and physiological parameters, including heart rate, mean blood pressure, respiratory frequency and rectal temperature, were recorded before and 0, 30, 60, 90, 120, 180 and 240 mins after brimonidine administration. RESULTS: Emesis and retching were not observed when maropitant was administered. However, 4/5 cats exhibited vomiting and retching in the absence of maropitant pretreatment. The incidence of emesis and retching after brimonidine administration was significantly lower in the treatment group than in the control group. Sialorrhoea occurred in one cat in the control group, while all cats showed lip-licking after brimonidine administration. There were no significant differences in the incidence of sialorrhoea and lip-licking between the two groups. Although behaviour scores were comparable between the two groups, those obtained during heart rate, mean blood pressure and respiratory frequency measurements were significantly lower than the baseline scores; this indicated a sedative effect after brimonidine administration. The heart rate and mean blood pressure significantly decreased after brimonidine administration in both groups, while there were no intergroup differences in the heart rate, mean blood pressure, respiratory frequency and rectal temperature. CONCLUSIONS AND RELEVANCE: Oral maropitant treatment before the administration of brimonidine ophthalmic solution in cats can alleviate emesis and retching without affecting the sedative effects of brimonidine and important physiological parameters.


Assuntos
Antieméticos/uso terapêutico , Tartarato de Brimonidina/administração & dosagem , Gatos/fisiologia , Soluções Oftálmicas/administração & dosagem , Quinuclidinas/uso terapêutico , Administração Oral , Animais , Estudos Cross-Over , Valores de Referência
3.
Sci Rep ; 8(1): 9263, 2018 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-29915185

RESUMO

This paper proposes a novel non-invasive method for assessing the vascular endothelial function of lower-limb arteries based on the dilation rate of air-cuff plethysmograms measured using the oscillometric approach. The principle of evaluating vascular endothelial function involves flow-mediated dilation. In the study conducted, blood flow in the dorsal pedis artery was first monitored while lower-limb cuff pressure was applied using the proposed system. The results showed blood flow was interrupted when the level of pressure was at least 50 mmHg higher than the subject's lower-limb systolic arterial pressure and that blood flow velocity increased after cuff release. Next, values of the proposed index, %ezFMDL, for assessing the vascular endothelial function of lower-limb arteries were determined from 327 adult subjects: 87 healthy subjects, 150 subjects at high risk of arteriosclerosis and 90 patients with cardiovascular disease (CAD). The mean values and standard deviations calculated using %ezFMDL were 30.5 ± 12.0% for the healthy subjects, 23.6 ± 12.7% for subjects at high risk of arteriosclerosis and 14.5 ± 15.4% for patients with CAD. The %ezFMDL values for the subjects at high risk of arteriosclerosis and the patients with CAD were significantly lower than those for the healthy subjects (p < 0.01). The proposed method may have potential for clinical application.


Assuntos
Endotélio Vascular/fisiologia , Extremidade Inferior/fisiologia , Vasodilatação/fisiologia , Adulto , Área Sob a Curva , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Curva ROC , Fluxo Sanguíneo Regional/fisiologia , Adulto Jovem
4.
J Am Heart Assoc ; 5(12)2016 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-28003249

RESUMO

BACKGROUND: A new device for automatic measurement of flow-mediated vasodilation (FMD) using an oscillometric method has been developed to solve technical problems of conventional FMD measurement. This device measures enclosed zone FMD (ezFMD). The purpose of this study was to evaluate the prognostic value of endothelial function assessed by ezFMD for future cardiovascular events. METHODS AND RESULTS: We measured ezFMD in 272 participants who underwent health-screening examinations. First, we investigated cross-sectional associations between ezFMD and cardiovascular risk factors, and then we assessed the associations between ezFMD and first major cardiovascular events (death from cardiovascular causes, stroke, and coronary revascularization). Univariate regression analysis revealed that ezFMD was significantly correlated with age, triglycerides, glucose, smoking pack-years, estimated glomerular filtration rate, high-sensitivity C-reactive protein, and Framingham risk score. During a median follow-up period of 36.1 months (interquartile range 18.8-40.1 months), 12 participants died (6 from cardiovascular causes), 3 had stroke, 8 had coronary revascularization, and 10 were hospitalized for heart failure. There was no episode of acute coronary syndrome during the study period. Participants were divided into tertiles (low, intermediate, and high) based on ezFMD. Kaplan-Meier curves for first major cardiovascular events among the 3 groups were significantly different (P=0.004). After adjustment for cardiovascular risk factors, the low group was significantly associated with an increased risk of first major cardiovascular events compared with the high group (hazard ratio 6.47; 95% CI 1.09-125.55; P=0.038). CONCLUSIONS: These findings suggest that endothelial function assessed by ezFMD may be useful as a surrogate marker of future cardiovascular events. CLINICAL TRIAL REGISTRATION: URL: https://upload.umin.ac.jp. Unique identifier: UMIN000004902.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Braquial/fisiopatologia , Doenças Cardiovasculares/diagnóstico , Endotélio Vascular/fisiopatologia , Oscilometria/instrumentação , Vasodilatação/fisiologia , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/fisiopatologia , Estudos Transversais , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos
5.
Atherosclerosis ; 229(2): 324-30, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23880183

RESUMO

BACKGROUND: It is clinically important to estimate the degree of endothelial dysfunction. Several methods have been used to assess endothelial function in humans. Recently, we developed a new noninvasive method for measurement of vascular response to reactive hyperemia in the brachial artery, named enclosed zone flow-mediated vasodilation (ezFMD). The purpose of this study was to determine the validity of ezFMD for assessment of endothelial function. METHODS AND RESULTS: We measured ezFMD by a new device using an oscillometric method and conventional FMD using ultrasonography in 306 subjects, including patients with hypertension, dyslipidemia, and diabetes mellitus (218 men and 88 women, 30 ± 16 yr). Univariate regression analysis revealed that ezFMD significantly correlated with age (r = -0.42, P < 0.0001), body mass index (r = -0.13, P = 0.028), systolic blood pressure (r = -0.15, P = 0.009), diastolic blood pressure (r = -0.14, P = 0.011), fasting glucose level (r = -0.27, P = 0.006), smoking (r = -0.21, P = 0.007) and baseline pulse wave amplitude (r = -0.51, P < 0.0001). ezFMD significantly correlated with conventional FMD (r = 0.34, P < 0.0001). Multiple regression analysis revealed that age (P = 0.002), body mass index (P = 0.013), systolic blood pressure (P = 0.009), smoking (P = 0.004) and baseline pulse wave amplitude (P < 0.001) were independent predictors of ezFMD. CONCLUSIONS: These findings suggest that measurement of ezFMD, a novel noninvasive and simple method, may be useful for determination of vascular diameter response to reactive hyperemia. Since ezFMD is automatically measured by a device with an oscillometric method, measurement of ezFMD is easier and less biased than that of conventional FMD.


Assuntos
Aterosclerose/diagnóstico , Aterosclerose/fisiopatologia , Endotélio Vascular/fisiologia , Oscilometria/métodos , Fluxo Sanguíneo Regional/fisiologia , Vasodilatação/fisiologia , Adolescente , Adulto , Pressão Sanguínea/fisiologia , Artéria Braquial/fisiologia , Diabetes Mellitus/fisiopatologia , Dislipidemias/fisiopatologia , Feminino , Humanos , Hiperemia/fisiopatologia , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Oscilometria/instrumentação , Adulto Jovem
6.
J Biol Chem ; 288(25): 18393-405, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23645672

RESUMO

Under pathological conditions such as ischemia-reperfusion, Nrf2 acts as a key regulator of cellular oxidative response. Provided that Nrf2 is sensitive to hypoxia during ischemia, Nrf2 may affect reactive oxygen species metabolism during reoxygenation. In this study, hypoxia suppressed Nrf2 protein, and its hypoxic suppression was not recovered with knockdown of the Nrf2 repressor Keap1. Moreover, an Nrf2 mutant lacking the Keap1 binding domain was suppressed under hypoxia, suggesting that Keap1 does not contribute to hypoxic Nrf2 suppression. HIF-1α and Siah2 are both key regulators of hypoxic responses. Hypoxia induced the Siah2 protein. Although inhibition or knockdown of Siah2 prevented the suppression of Nrf2, knockdown of HIF-1α did not. Moreover, Siah2 interacted with Nrf2 through a binding motif, suggesting that Siah2 contributes to the suppression of Nrf2. Some cytosolic kinases also play important roles in Nrf2 regulation. In this study, PKC phosphorylates serine residues of Nrf2 during hypoxia. Knockdown of Siah2 rescued hypoxic decreases in an Nrf2 mutant that mimicked phosphorylation at serine 40 or lacked this phosphorylation site, suggesting that Siah2 contributes to the degradation of Nrf2 irrespective of its phosphorylation status. Moreover, knockdown of Siah2 attenuated ubiquitination of the Nrf2 mutant, suggesting that association of Siah2 with Nrf2 causes proteasome-mediated degradation of Nrf2.


Assuntos
Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Fator 2 Relacionado a NF-E2/metabolismo , Proteínas Nucleares/metabolismo , Ubiquitina-Proteína Ligases/metabolismo , Western Blotting , Hipóxia Celular , Linhagem Celular Tumoral , Células HEK293 , Células HeLa , Humanos , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Peptídeos e Proteínas de Sinalização Intracelular/genética , Proteína 1 Associada a ECH Semelhante a Kelch , Fator 2 Relacionado a NF-E2/genética , Proteínas Nucleares/genética , Fosforilação , Ligação Proteica , Proteína Quinase C/metabolismo , Proteólise , Interferência de RNA , Ubiquitina-Proteína Ligases/genética , Ubiquitinação
7.
Med Biol Eng Comput ; 50(12): 1239-47, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23054376

RESUMO

Measurement of flow-mediated dilatation (FMD) is the conventional non-invasive method for assessment of endothelial function; however, it requires an expensive ultrasound system and high levels of technical skill. Therefore, we developed a novel method for measurement of endothelial function, namely, measurement of ezFMD. ezFMD estimates the degree of vasodilatation from the oscillation signals transmitted to a sphygmomanometer cuff attached to the upper arm. The objective of this study was to validate the principle underlying the measurement of ezFMD, and to evaluate the repeatability of the ezFMD measurements. We observed the blood vessel behavior and oscillometric pattern in ten subjects. When the cuff was inflated to the level of the mean blood pressure, the oscillation amplitude increased with increasing degree of vasodilatation. In experiment to evaluate the repeatability of the ezFMD measurement, the average difference between the paired measurements was 3.7 %, the standard deviation was 11.5 %, and the average coefficient of variation value for the 11 paired measurements was 23.7 %. These results suggest the validity of the principle underlying the measurement of the ezFMD for the assessment of endothelial function. And, this study suggests that the repeatability of the ezFMD measurements is superior to that of the conventional measurement of FMD.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Endotélio Vascular/fisiologia , Processamento de Sinais Assistido por Computador , Adulto , Algoritmos , Artéria Braquial/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Oscilometria , Reprodutibilidade dos Testes , Esfigmomanômetros , Vasodilatação
8.
FEBS Lett ; 582(16): 2357-64, 2008 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-18538669

RESUMO

We identified MafG as a protein that interacts with HIF-1alpha, a key factor in hypoxic response, using the yeast two-hybrid system. Interaction between MafG and HIF-1alpha was confirmed by surface plasmon resonance and by translocation to the nucleolus with the NoLS signal. A knockdown of MafG reduced erythropoietin (EPO) mRNA levels as well as luciferase reporter activity with the hypoxia response element. The knockdown of MafG did not change total HIF-1alpha protein, but reduced the accumulation of HIF-1alpha in the nuclei. These results suggest that MafG regulates the hypoxic response of cells by detaining HIF-1alpha in the nuclei.


Assuntos
Núcleo Celular/metabolismo , Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Fator de Transcrição MafG/fisiologia , Proteínas Repressoras/fisiologia , Hipóxia Celular , Linhagem Celular Tumoral , Genes Reporter , Humanos , Fator de Transcrição MafG/antagonistas & inibidores , Fator de Transcrição MafG/genética , Interferência de RNA , Proteínas Repressoras/antagonistas & inibidores , Proteínas Repressoras/genética , Técnicas do Sistema de Duplo-Híbrido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...