1.
Appl Opt ; 48(10): D144-50, 2009 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-19340103

RESUMO

We present and demonstrate a swept source with a large coherence length using a quasi-phase continuous tuning (QPCT) technique. QPCT is a method of minimizing the phase shift per round trip with respect to the tunable filter so that the resonance of lasing becomes high, resulting in high finesse of lasing during a rapid sweep. The demonstrated swept source consists of a fiber ring extended cavity laser with a diffraction grating and a polygon scanner-based tunable filter configuration. The projected beam on the diffraction grating is expanded with a multiple of beam expanders to achieve high finesse of the filter. The source demonstrated an 18 nm swept range at 1060 nm wavelength, 28 mm coherence length, and 6.2 mW peak power at a 2.5 kHz swept rate. OCT imaging results showed that a coherence length of 28 mm enables the measurement of the axial length of a pig's eye with 20 mm length in physical size.


Assuntos
Olho/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Animais , Desenho de Equipamento , Técnicas In Vitro , Lasers , Tamanho do Órgão , Reprodutibilidade dos Testes , Suínos , Tomografia de Coerência Óptica/instrumentação
2.
Opt Express ; 16(25): 21105-18, 2008 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-19065251

RESUMO

This paper reports on a technique to improve the coherence length of a high-speed wavelength swept laser. The wavelength swept laser comprises a pigtailed semiconductor optical amplifier and a wavelength-scanning filter in a fiber extended cavity configuration. The laser operates in the 1310 nm wavelength region. The tunable filter consists of a diffraction grating and polygon mirror scanner. Littrow arrangement of external cavity in a specific geometry realizes the quasi-phase continuous tuning over wavelength range emphasizing coherent amplification of cavity modes resulting in spectral narrowing of the instantaneous linewidth to about 0.06 nm. Improvement by a factor of two is confirmed in comparison with coherence length without using this technique. Peak power is 12 mW and wavelength swept range is 55 nm, from 1271 nm to 1326 nm. Measured coherence lengths of over 30 mm and 17 mm were achieved at scanning rates of 2.5 kHz and 20 kHz, respectively. Correlation of laser cavity parameters with spectral linewidth is also discussed by introducing the rate equations for multi-mode laser operation. Shorter cavity length is considered effective to further improve the coherence length in terms of shorter roundtrip time as well as higher mode suppression ratio because of higher carrier concentration on cavity modes around the filter center.


Assuntos
Desenho Assistido por Computador , Aumento da Imagem/instrumentação , Interferometria/instrumentação , Lasers , Iluminação/instrumentação , Modelos Teóricos , Tomografia de Coerência Óptica/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Espalhamento de Radiação
3.
Opt Express ; 13(26): 10652-64, 2005 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-19503280

RESUMO

A two- and three-dimensional swept source optical coherence tomography (SS-OCT) system, which uses a ready-to-ship scanning light source, is demonstrated. The light source has a center wavelength of 1.31 mum, -3 dB wavelength range of 110 nm, scanning rate of 20 KHz, and high linearity in frequency scanning. This paper presents a simple calibration method using a fringe analysis technique for spectral rescaling. This SS-OCT system is capable of realtime display of two-dimensional OCT and can obtain three-dimensional OCT with a measurement time of 2 s. In vivo human anterior eye segments are investigated two- and three-dimensionally. The system sensitivity is experimentally determined to be 114 dB. The three-dimensional OCT volumes reveal the structures of the anterior eye segments, which are difficult to observe in two-dimensional OCT images.