Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Sci ; 108(9): 2949-2963, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31004652

RESUMO

The accumulation of electrostatic charge on drug particles and excipient powders arising from interparticulate collisions or contacts with other surfaces can lead to agglomeration and adhesion problems during the manufacturing process, filling, and delivery of dry powder inhaler (DPI) formulations. The objective of the study was to investigate the role of triboelectrification to better understand the influence of electrostatic charge on the performance of DPIs with 2 capsule-based dimensionally similar devices constructed with different materials. In addition, strategies to reduce electrostatic charge build up during the manufacturing process, and the processes involved in this phenomenon were investigated. Electrostatic charge measurements showed that there was a significant difference in electrostatic charge generated between tested formulations and devices. This affects particle detachment from carrier and thus significantly impacts aerosol performance. Conditioning fluticasone DPI capsules at defined temperature and humidity conditions reduced electrostatic charges acquired during manufacturing. Conditioning salmeterol DPI capsules at same conditions seemed disadvantageous for their aerosol performance because of increasing capillary forces and solid bridge formation caused by water absorption. Knowledge and understanding of the role of electrostatic forces in influencing DPI formulation performance was increased by these studies.


Assuntos
Embalagem de Medicamentos/instrumentação , Inaladores de Pó Seco/instrumentação , Fluticasona/química , Xinafoato de Salmeterol/química , Eletricidade Estática , Resinas Acrílicas/química , Administração por Inalação , Aerossóis , Butadienos/química , Química Farmacêutica , Estabilidade de Medicamentos , Fluticasona/administração & dosagem , Umidade , Tamanho da Partícula , Poliestirenos/química , Pós , Xinafoato de Salmeterol/administração & dosagem , Propriedades de Superfície , Temperatura , Titânio/química
2.
J Pharm Sci ; 107(4): 984-998, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29247741

RESUMO

The potential of the force control agent magnesium stearate (MgSt) to enhance the aerosol performance of lactose-based dry powder inhaled (DPI) formulations was investigated in this study. The excipient-blends were investigated with analytical techniques including time-of-flight secondary ion mass spectrometry and single particle aerosol mass spectrometry (SPAMS), and particle size, morphology, and surface properties were evaluated. Excipient-blends were manufactured either by high-shear or low-shear blending lactose carrier with different amounts of MgSt in the range from 0% to 10% (w/w). Fluticasone propionate (FP) and salmeterol xinafoate (SX) used as model active pharmaceutical ingredients were added by low-shear mixing. The in vitro aerosol performance in terms of aerodynamic particle size distribution and fine particle fraction (FPF) of the FP and SX DPI formulations was evaluated with the Next Generation Impactor and also with SPAMS using a Breezhaler® inhalation device. The distribution of MgSt on the lactose carrier in the blends was visualized and found to depend strongly on the blending method. This affected drug particle detachment from the carrier and thus impacted aerosol performance for FP and SX. Compared with blends without force control agent, low-shear blending of MgSt increases the FPF of the model drug SX, whereas high-shear blending significantly increased FPF of both SX and FP. The interactions between drug and carrier particles were substantially affected by the choice of blending technique of MgSt with lactose. This allows detailed control of aerosol performance of a DPI by an adequate choice of the blending technique. SPAMS successfully demonstrated that it is capable to distinguish changes in DPI formulations blended with different amounts of MgSt, and additional information in terms of dispersibility of fine particles could be generated.


Assuntos
Aerossóis/química , Pós/química , Ácidos Esteáricos/química , Administração por Inalação , Química Farmacêutica/métodos , Portadores de Fármacos/química , Composição de Medicamentos/métodos , Inaladores de Pó Seco/métodos , Excipientes/química , Lactose/química , Tamanho da Partícula , Propriedades de Superfície
3.
Int J Pharm ; 532(1): 218-228, 2017 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-28864391

RESUMO

Particle co-associations between the active pharmaceutical ingredients fluticasone propionate and salmeterol xinafoate were examined in dry powder inhaled (DPI) and metered dose inhaled (MDI) combination products. Single Particle Aerosol Mass Spectrometry was used to investigate the particle interactions in Advair Diskus® (500/50 mcg) and Seretide® (125/25 mcg). A simple rules tree was used to identify each compound, either alone or co-associated at the level of the individual particle, using unique marker peaks in the mass spectra for the identification of each drug. High levels of drug particle co-association (fluticasone-salmeterol) were observed in the aerosols emitted from Advair Diskus® and Seretide®. The majority of the detected salmeterol particles were found to be in co-association with fluticasone in both tested devices. Another significant finding was that rather coarse fluticasone particles (in DPI) and fine salmeterol particles (both MDI and DPI) were forming the particle co-associations.


Assuntos
Combinação Fluticasona-Salmeterol/química , Agonistas de Receptores Adrenérgicos beta 2/química , Aerossóis , Broncodilatadores/química , Inaladores de Pó Seco , Glucocorticoides/química , Espectrometria de Massas , Inaladores Dosimetrados
4.
Int J Pharm ; 489(1-2): 11-7, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25891255

RESUMO

The use of single particle aerosol mass spectrometry (SPAMS) was evaluated for the analysis of inhaled pharmaceuticals to determine the mass distribution of the individual active pharmaceutical ingredients (API) in both single ingredient and combination drug products. SPAMS is an analytical technique where the individual aerodynamic diameters and chemical compositions of many aerosol particles are determined in real-time. The analysis was performed using a Livermore Instruments SPAMS 3.0, which allowed the efficient analysis of aerosol particles with broad size distributions and can acquire data even under a very large particle load. Data similar to what would normally require roughly three days of experimentation and analysis was collected in a five minute period and analyzed automatically. The results were computed to be comparable to those returned by a typical Next Generation Impactor (NGI) particle size distribution experiment.


Assuntos
Aerossóis/análise , Espectrometria de Massas/métodos , Inaladores Dosimetrados , Albuterol/análise , Combinação Albuterol e Ipratrópio , Broncodilatadores/análise , Fluticasona/análise , Combinação Fluticasona-Salmeterol , Ipratrópio/análise , Sistemas On-Line , Tamanho da Partícula , Xinafoato de Salmeterol/análise
5.
PDA J Pharm Sci Technol ; 61(4): 226-36, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17933206

RESUMO

A direct test method using helium leak detection was developed to determine microbial ingress in parenteral vial/rubber closure systems. The purpose of this study was to establish a direct correlation between the helium leak rate and the presence of ingress when vials were submersed under pressure in a broth of bacteria. Results were obtained for two different types of leaks: microholes that have been laser-drilled into thin metal plates, and thin copper wire that was placed between the rubber closure and the glass vial's sealing surface. The results from the microholes showed that the helium leak rate was a function of the square of the hole diameter and fit well with theoretical calculations. The relationship with the wire gave a far more complex dependence and was not modeled theoretically. Comparison with the microbial challenge showed that for microholes a lower size limit was found to be 2 microm with a corresponding leak rate of 1.4 x 10(-3) mbarl/s. For the fine wire experiment the lower limit was 15-microm wire and a corresponding leak rate of 1.3 x 10(-5) mbarl/s. From these tests a safe, lower limit, leak rate was established.


Assuntos
Contaminação de Medicamentos/prevenção & controle , Embalagem de Medicamentos/normas , Enterobacteriaceae/crescimento & desenvolvimento , Hélio/análise , Infusões Parenterais/normas , Tecnologia Farmacêutica , Contaminação de Equipamentos , Vidro , Espectrometria de Massas , Modelos Teóricos , Pressão , Controle de Qualidade , Borracha , Tecnologia Farmacêutica/instrumentação , Tecnologia Farmacêutica/métodos
6.
Environ Sci Technol ; 36(22): 4868-79, 2002 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-12487311

RESUMO

Aerosol time-of-flight mass spectrometry (ATOFMS) instruments measure the size and chemical composition of individual particles in real-time. ATOFMS chemical composition measurements are difficult to quantify, largely because the instrument sensitivities to different chemical species in mixed ambient aerosols are unknown. In this paper, we develop a field-based approach for determining ATOFMS instrument sensitivities to ammonium and nitrate in size-segregated atmospheric aerosols, using tandem ATOFMS-impactor sampling. ATOFMS measurements are compared with collocated impactor measurements taken at Riverside, CA, in September 1996, August 1997, and October 1997. This is the first comparison of ion signal intensities from a single-particle instrument with quantitative measurements of atmospheric aerosol chemical composition. The comparison reveals that ATOFMS instrument sensitvities to both NH4+ and NO3- decline with increasing particle aerodynamic diameter over a 0.32-1.8 microm calibration range. The stability of this particle size dependence is tested overthe broad range of fine particle concentrations (PM1.8) = 17.6 +/- 2.0-127.8 +/- 1.8 microg m(-3)), ambient temperatures (23-35 degrees C), and relative humidity conditions (21-69%), encountered during the field experiments. This paper describes a potentially generalizable methodology for increasing the temporal and size resolution of atmospheric aerosol chemical composition measurements, using tandem ATOFMS-impactor sampling.


Assuntos
Monitoramento Ambiental/instrumentação , Espectrometria de Massas/instrumentação , Nitratos/análise , Compostos de Amônio Quaternário/análise , Aerossóis , Umidade , Tamanho da Partícula , Sensibilidade e Especificidade , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...