Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Sci Rep ; 9(1): 2677, 2019 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-30804413

RESUMO

Performance of astronaut pilots during space shuttle landing was degraded after a few weeks of microgravity exposure, and longer-term exposure has the potential to impact operator proficiency during critical landing and post-landing operations for exploration-class missions. Full-motion simulations of operationally-relevant tasks were utilized to assess the impact of long-duration spaceflight on operator proficiency in a group of 8 astronauts assigned to the International Space Station, as well as a battery of cognitive/sensorimotor tests to determine the underlying cause of any post-flight performance decrements. A ground control group (N = 12) and a sleep restriction cohort (N = 9) were also tested to control for non-spaceflight factors such as lack of practice between pre- and post-flight testing and fatigue. On the day of return after 6 months aboard the space station, astronauts exhibited significant deficits in manual dexterity, dual-tasking and motion perception, and a striking degradation in the ability to operate a vehicle. These deficits were not primarily due to fatigue; performance on the same tasks was unaffected after a 30-h period of sleep restriction. Astronauts experienced a general post-flight malaise in motor function and motion perception, and a lack of cognitive reserve apparent only when faced with dual tasks, which had recovered to baseline by four days after landing.


Assuntos
Astronautas/estatística & dados numéricos , Voo Espacial , Astronave , Ausência de Peso , Adulto , Astronautas/psicologia , Cognição/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Percepção de Movimento/fisiologia , Testes Psicológicos/estatística & dados numéricos , Desempenho Psicomotor/fisiologia , Sono/fisiologia , Fatores de Tempo
2.
Front Syst Neurosci ; 9: 88, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26106308

RESUMO

Performance on a visuomotor task in the presence of novel vestibular stimulation was assessed in nine healthy subjects. Four subjects had previously been adapted to 120 min exposure to noisy Galvanic vestibular stimulation (GVS) over 12 weekly sessions of 10 min; the remaining five subjects had never experienced GVS. Subjects were seated in a flight simulator and asked to null the roll motion of a visual bar presented on a screen using a joystick. Both the visual bar and the simulator cabin were moving in roll with a pseudorandom (sum of sines) waveform that were uncorrelated. The cross correlation coefficient, which ranges from 1 (identical waveforms) to 0 (unrelated waveforms), was calculated for the ideal (perfect nulling of bar motion) and actual joystick input waveform for each subject. The cross correlation coefficient for the GVS-adapted group (0.90 [SD 0.04]) was significantly higher (t[8] = 3.162; p = 0.013) than the control group (0.82 [SD 0.04]), suggesting that prior adaptation to GVS was associated with an enhanced ability to perform the visuomotor task in the presence of novel vestibular noise.

3.
PLoS One ; 9(11): e112131, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25409443

RESUMO

Healthy subjects (N = 10) were exposed to 10-min cumulative pseudorandom bilateral bipolar Galvanic vestibular stimulation (GVS) on a weekly basis for 12 weeks (120 min total exposure). During each trial subjects performed computerized dynamic posturography and eye movements were measured using digital video-oculography. Follow up tests were conducted 6 weeks and 6 months after the 12-week adaptation period. Postural performance was significantly impaired during GVS at first exposure, but recovered to baseline over a period of 7-8 weeks (70-80 min GVS exposure). This postural recovery was maintained 6 months after adaptation. In contrast, the roll vestibulo-ocular reflex response to GVS was not attenuated by repeated exposure. This suggests that GVS adaptation did not occur at the vestibular end-organs or involve changes in low-level (brainstem-mediated) vestibulo-ocular or vestibulo-spinal reflexes. Faced with unreliable vestibular input, the cerebellum reweighted sensory input to emphasize veridical extra-vestibular information, such as somatosensation, vision and visceral stretch receptors, to regain postural function. After a period of recovery subjects exhibited dual adaption and the ability to rapidly switch between the perturbed (GVS) and natural vestibular state for up to 6 months.


Assuntos
Adaptação Fisiológica , Estimulação Elétrica/métodos , Postura , Voo Espacial , Adulto , Astronautas , Medições dos Movimentos Oculares , Movimentos Oculares , Humanos , Masculino , Sensação , Testes de Função Vestibular
4.
Parkinsons Dis ; 2014: 606427, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25101189

RESUMO

A cardinal feature of freezing of gait (FOG) is high frequency (3-8 Hz) oscillation of the legs, and this study aimed to quantify the temporal pattern of lower-body motion prior to and during FOG. Acceleration data was obtained from sensors attached to the back, thighs, shanks, and feet in 14 Parkinson's disease patients performing timed-up-and-go tasks, and clinical assessment of FOG was performed by two experienced raters from video. A total of 23 isolated FOG events, defined as occurring at least 5 s after gait initiation and with no preceding FOG, were identified from the clinical ratings. The corresponding accelerometer records were analyzed within a 4 s window centered at the clinical onset of freezing. FOG-related high-frequency oscillation (an increase in power in the 3-8 Hz band >3 SD from baseline) followed a distal to proximal onset pattern, appearing at the feet, shanks, thighs, and then back over a period of 250 ms. Peak power tended to decrease as the focus of oscillation moved from feet to back. There was a consistent delay (mean 872 ms) between the onset of high frequency oscillation at the feet and clinical onset of FOG. We infer that FOG is characterized by high frequency oscillation at the feet, which progresses proximally and is mechanically damped at the torso.

5.
J Neuroeng Rehabil ; 10: 19, 2013 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-23405951

RESUMO

BACKGROUND: We have previously published a technique for objective assessment of freezing of gait (FOG) in Parkinson's disease (PD) from a single shank-mounted accelerometer. Here we extend this approach to evaluate the optimal configuration of sensor placement and signal processing parameters using seven sensors attached to the lumbar back, thighs, shanks and feet. METHODS: Multi-segmental acceleration data was obtained from 25 PD patients performing 134 timed up and go tasks, and clinical assessment of FOG was performed by two experienced raters from video. Four metrics were used to compare objective and clinical measures; the intraclass correlation coefficient (ICC) for number of FOG episodes and the percent time frozen per trial; and the sensitivity and specificity of FOG detection. RESULTS: The seven-sensor configuration was the most robust, scoring highly on all measures of performance (ICC number of FOG 0.75; ICC percent time frozen 0.80; sensitivity 84.3%; specificity 78.4%). A simpler single-shank sensor approach provided similar ICC values and exhibited a high sensitivity to FOG events, but specificity was lower at 66.7%. Recordings from the lumbar sensor offered only moderate agreement with the clinical raters in terms of absolute number and duration of FOG events (likely due to musculoskeletal attenuation of lower-limb 'trembling' during FOG), but demonstrated a high sensitivity (86.2%) and specificity (82.4%) when considered as a binary test for the presence/absence of FOG within a single trial. CONCLUSIONS: The seven-sensor approach was the most accurate method for quantifying FOG, and is best suited to demanding research applications. A single shank sensor provided measures comparable to the seven-sensor approach but is relatively straightforward in execution, facilitating clinical use. A single lumbar sensor may provide a simple means of objective FOG detection given the ubiquitous nature of accelerometers in mobile telephones and other belt-worn devices.


Assuntos
Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Extremidade Inferior/fisiologia , Doença de Parkinson/complicações , Doença de Parkinson/fisiopatologia , Fenômenos Biomecânicos , Estudos de Coortes , Interpretação Estatística de Dados , Eletrodos , Feminino , Pé/fisiologia , Humanos , Perna (Membro)/fisiologia , Locomoção/fisiologia , Região Lombossacral/fisiologia , Masculino , Fenômenos Fisiológicos Musculoesqueléticos , Testes Neuropsicológicos , Desempenho Psicomotor/fisiologia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Software , Coxa da Perna/fisiologia
6.
Gait Posture ; 38(2): 326-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23332192

RESUMO

The current 'gold standard' for clinical evaluation of freezing of gait (FOG) in Parkinson's disease (PD) is determination of the number of FOG episodes from video by independent raters. We have previously described a robust technique for objective FOG assessment from lower-limb acceleration. However, there is no existing method for validation of autonomous FOG measures in the absence of video documentation. In this study we compared the results of clinical evaluation of FOG from computer-generated animations (derived from body-mounted inertial sensors) during a timed up and go test with the 'gold standard' of clinical video assessment, utilizing a cohort of 10 experienced raters from four PD centers. Agreement between the 10 clinical observers for scoring of FOG from computer animations was more robust for the relative duration of freeze events (percent time frozen; intraclass correlation coefficient of 0.65) than number of FOG episodes, and was comparable with clinical evaluation of the patient from video (intraclass correlation coefficient 0.73). This result suggests that percent time frozen should be considered (along with number of FOG events) to better convey FOG severity. The ability of clinical observers to quantify FOG from computer-generated animation derived from lower-limb motion data provides a potential approach to validation of accelerometry-based FOG identification outside of the clinic.


Assuntos
Diagnóstico por Computador/métodos , Transtornos Neurológicos da Marcha/diagnóstico , Doença de Parkinson/diagnóstico , Acelerometria/métodos , Idoso , Feminino , Transtornos Neurológicos da Marcha/etiologia , Humanos , Extremidade Inferior , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/complicações
7.
Parkinsonism Relat Disord ; 18(5): 572-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22445248

RESUMO

Freezing of gait, a paroxysmal motor block, is common in the latter stages of Parkinson's disease. The current 'gold standard' of assessing the severity of freezing is based on clinical identification (by up to 3 raters) of the number of episodes from video. The aims of this study were to systematically assess this 'gold standard' across multiple Parkinson's disease centers, and to compare these clinical ratings with objective measures derived from lower limb acceleration data. Video recordings were acquired during a timed up-and-go task from 10 Parkinson's disease patients (with a clinical history of freezing) in the 'off' state. Patients were instrumented with accelerometers on the lateral aspect of each shank. Ten experienced clinicians were recruited from four Parkinson's disease centers to independently assess the videos for number and duration of freezing events. The reliability of clinical video assessment for number of freezing events was moderate (intraclass correlation coefficient 0.63). Percent time frozen (cumulative duration of freezing episodes/total duration of the walking task) demonstrated stronger agreement between raters (0.73). Agreement of accelerometry-derived measures of freezing severity with mean clinician ratings was strong for number of episodes (0.78) and very strong for percent time frozen (0.93). The results demonstrate the viability of objective measures of freezing, and that percent time frozen is a more reliable metric of severity than number of freezing events for both clinical and objective measures. The large variability between clinicians suggests that caution should be used when comparing subjective ratings across centers.


Assuntos
Reação de Congelamento Cataléptica/fisiologia , Transtornos Neurológicos da Marcha/diagnóstico , Transtornos Neurológicos da Marcha/etiologia , Doença de Parkinson/complicações , Idoso , Feminino , Humanos , Cinetocardiografia , Locomoção/fisiologia , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/terapia , Reprodutibilidade dos Testes , Autorrelato , Índice de Gravidade de Doença , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...