1.
Bone ; 177: 116901, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37714502

RESUMO

Despite effective therapies for those at risk of osteoporotic fracture, low adherence to screening guidelines and limited accuracy of bone mineral density (BMD) in predicting fracture risk preclude identification of those at risk. Because of high adherence to routine mammography, bone health screening at the time of mammography using a digital breast tomosynthesis (DBT) scanner has been suggested as a potential solution. BMD and bone microstructure can be measured from the wrist using a DBT scanner. However, the extent to which biomechanical variables can be derived from digital wrist tomosynthesis (DWT) has not been explored. Accordingly, we measured stiffness from a DWT based finite element (DWT-FE) model of the ultra-distal (UD) radius and ulna, and correlate these to reference microcomputed tomography image based FE (µCT-FE) from five cadaveric forearms. Further, this method is implemented to determine in vivo reproducibility of FE derived stiffness of UD radius and demonstrate the in vivo utility of DWT-FE in bone quality assessment by comparing two groups of postmenopausal women with and without a history of an osteoporotic fracture (Fx; n = 15, NFx; n = 51). Stiffness obtained from DWT and µCT had a strong correlation (R2 = 0.87, p < 0.001). In vivo repeatability error was <5 %. The NFx and Fx groups were not significantly different in DXA derived minimum T-scores (p > 0.3), but stiffness of the UD radius was lower for the Fx group (p < 0.007). Logistic regression models of fracture status with stiffness of the nondominant arm as the predictor were significant (p < 0.01). In conclusion this study demonstrates the feasibility of fracture risk assessment in mammography settings using DWT imaging and FE modeling in vivo. Using this approach, bone and breast screening can be performed in a single visit, with the potential to improve both the prevalence of bone health screening and the accuracy of fracture risk assessment.

2.
J Appl Clin Med Phys ; 24(2): e13870, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36519622

RESUMO

PURPOSE: This work investigates the impact of tissue-equivalent attenuator choice on measured signal-to-noise ratio (SNR) for automatic exposure control (AEC) performance evaluation in digital mammography. It also investigates how the SNR changes for each material when used to evaluate AEC performance across different mammography systems. METHODS: AEC performance was evaluated for four mammography systems using seven attenuator sets at two thicknesses (4 and 8 cm). All systems were evaluated in 2D imaging mode, and one system was evaluated in digital breast tomosynthesis (DBT) mode. The methodology followed the 2018 ACR digital mammography quality control (DMQC) manual. Each system-attenuator-thickness combination was evaluated using For Processing images in ImageJ with standard ROI size and location. The closest annual physicist testing results were used to explore the impact of varying measured AEC performance on image quality. RESULTS: The measured SNR varied by 44%-54% within each system across all attenuators at 4 cm thickness in 2D mode. The variation appeared to be largely due to changes in measured noise, with variations of 46%-67% within each system across all attenuators at 4 cm thickness in 2D mode. Two systems had failing SNR levels for two of the materials using the minimum SNR criterion specified in the ACR DMQC manual. Similar trends were seen in DBT mode and at 8 cm thickness. Within each material, there was 115%-131% variation at 4 cm and 82%-114% variation at 8 cm in the measured SNR across the four imaging systems. Variation in SNR did not correlate with system operating level based on visual image quality and average glandular dose (AGD). CONCLUSION: Choice of tissue-equivalent attenuator for AEC performance evaluation affects measured SNR values. Depending on the material, the difference may be enough to result in failure following the longitudinal and absolute thresholds specified in the ACR DMQC manual.


Assuntos
Mamografia , Intensificação de Imagem Radiográfica , Humanos , Imagens de Fantasmas , Mamografia/métodos , Razão Sinal-Ruído , Controle de Qualidade , Intensificação de Imagem Radiográfica/métodos
3.
Bone ; 144: 115804, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33321264

RESUMO

Bone fractures attributable to osteoporosis are a significant problem. Though preventative treatment options are available for individuals who are at risk of a fracture, a substantial number of these individuals are not identified due to lack of adherence to bone screening recommendations. The issue is further complicated as standard diagnosis of osteoporosis is based on bone mineral density (BMD) derived from dual energy x-ray absorptiometry (DXA), which, while helpful in identifying many at risk, is limited in fully predicting risk of fracture. It is reasonable to expect that bone screening would become more prevalent and efficacious if offered in coordination with digital breast tomosynthesis (DBT) exams, provided that osteoporosis can be assessed using a DBT modality. Therefore, the objective of the current study was to explore the feasibility of using digital tomosynthesis imaging in a mammography setting. To this end, we measured density, cortical thickness and microstructural properties of the wrist bone, correlated these to reference measurements from microcomputed tomography and DXA, demonstrated the application in vivo in a small group of participants, and determined the repeatability of the measurements. We found that measurements from digital wrist tomosynthesis (DWT) imaging with a DBT scanner were highly repeatable ex vivo (error = 0.05%-9.62%) and in vivo (error = 0.06%-10.2%). In ex vivo trials, DWT derived BMDs were strongly correlated with reference measurements (R = 0.841-0.980), as were cortical thickness measured at lateral and medial cortices (R = 0.991 and R = 0.959, respectively) and the majority of microstructural measures (R = 0.736-0.991). The measurements were quick and tolerated by human patients with no discomfort, and appeared to be different between young and old participants in a preliminary comparison. In conclusion, DWT is feasible in a mammography setting, and informative on bone mass, cortical thickness, and microstructural qualities that are known to deteriorate in osteoporosis. To our knowledge, this study represents the first application of DBT for imaging bone. Future clinical studies are needed to further establish the efficacy for diagnosing osteoporosis and predicting risk of fragility fracture using DWT.


Assuntos
Densidade Óssea , Neoplasias da Mama , Absorciometria de Fóton , Feminino , Humanos , Mamografia , Punho/diagnóstico por imagem , Microtomografia por Raio-X
4.
Invest Radiol ; 52(4): 198-205, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27898602

RESUMO

OBJECTIVE: Currently, dynamic contrast-enhanced (DCE) breast magnetic resonance imaging (MRI) prioritizes spatial resolution over temporal resolution given the limitations of acquisition techniques. The purpose of our intrapatient study was to assess the ability of a novel high spatial and high temporal resolution DCE breast MRI method to maintain image quality compared with the clinical standard-of-care (SOC) MRI. MATERIALS AND METHODS: Thirty patients, each demonstrating a focal area of enhancement (29 benign, 1 cancer) on their SOC MRI, consented to undergo a research DCE breast MRI on a second date. For the research DCE MRI, a method (DIfferential Subsampling with Cartesian Ordering [DISCO]) using pseudorandom k-space sampling, view sharing reconstruction, 2-point Dixon fat-water separation, and parallel imaging was used to produce images with an effective temporal resolution 6 times faster than the SOC MRI (27 vs 168 seconds, respectively). Both the SOC and DISCO MRI scans were acquired with matching spatial resolutions of 0.8 × 0.8 × 1.6 mm. Image quality (distortion/artifacts, resolution, fat suppression, lesion conspicuity, perceived signal-to-noise ratio, and overall image quality) was scored by 3 radiologists in a blinded reader study. RESULTS: Differences in image quality scores between the DISCO and SOC images were all less than 0.8 on a 10-point scale, and both methods were assessed as providing diagnostic image quality in all cases. DISCO images with the same high spatial resolution, but 6 times the effective temporal resolution as the SOC MRI scans, were produced, yielding 20 postcontrast time points with DISCO compared with 3 for the SOC MRI, over the same total time interval. CONCLUSIONS: DISCO provided comparable image quality compared with the SOC MRI, while also providing 6 times faster effective temporal resolution and the same high spatial resolution.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Artefatos , Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Razão Sinal-Ruído
5.
Int J Radiat Oncol Biol Phys ; 79(4): 1043-7, 2011 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-20471182

RESUMO

PURPOSE: To determine factors predictive for hematologic toxicity (HT) associated with concurrent chemoradiation for Stage II through IV cervical cancer. METHODS AND MATERIALS: The medical records of 40 women receiving concurrent chemoradiation for cervical cancer were reviewed. Hematologic toxicity was defined by use of Common Terminology Criteria for Adverse Events (version 3.0). Variables predicting for HT including age, body mass index, transfusions, and bone marrow volumes irradiated were included in the data analysis. RESULTS: Of the patients, 13 (32.5%) had Grade 0 or 1 HT and 27 (67.5%) had Grade 2 through 4 HT (HT2+). Multiple logistic regression analysis of potential predictors showed that only the volume of bone receiving 20 Gy (V20) for whole pelvic bone tended toward significance for predicting HT2+. A strong correlation was noted between HT2+ and V20 (r = 0.8, p < 0.0001). A partitioning analysis to predict HT2+ showed a cutoff value of 79.42% (approximately 80%) for V20 of whole pelvic bone. That is, if the V20 of the whole pelvis exceeds 80%, the risk of HT2+ developing increases by a factor (odds ratio) of 4.5 (95%, confidence interval, 1.08-18.69) (p < 0.05). CONCLUSIONS: We have shown a correlation between bone marrow volume radiated and development of HT. This has implications for use of pelvic intensity-modulated radiation therapy, which can potentially decrease the volume of bone marrow radiated.


Assuntos
Medula Óssea/efeitos da radiação , Lesões por Radiação/prevenção & controle , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Antineoplásicos/efeitos adversos , Antineoplásicos/uso terapêutico , Medula Óssea/anatomia & histologia , Cisplatino/efeitos adversos , Cisplatino/uso terapêutico , Terapia Combinada/efeitos adversos , Terapia Combinada/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Pelve , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Análise de Regressão , Neoplasias do Colo do Útero/tratamento farmacológico , Neoplasias do Colo do Útero/patologia