Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 30(3): 643-49, 2002 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-12367689

RESUMO

A high-performance liquid chromatography isocratic procedure was developed for the assay of cefetamet pivoxil hydrochloride in drug substance and powder for oral suspension. The method validation yielded good results and included the range, linearity, precision intra- inter-day, accuracy, specificity, LOD and LOQ values. The chromatographic system consisted of a C(18) absorbosphere column (150 x 4.6 mm i.d., 5 microm particle size), a mobile phase composed of water-acetonitrile-methanol-phosphate buffer, pH 3.5 (50:35:10:5, v/v), flow rate of 1.5 ml min(-1) and UV detection at 254 nm. The relative standard deviation varied between 0.03 and 1.76%, and accuracy of 100.09% was found. Calibration curve was linear from 30.0-80.0 microg ml(-1); its correlation coefficient was 0.99989.


Assuntos
Ceftizoxima/análogos & derivados , Ceftizoxima/análise , Administração Oral , Ceftizoxima/química , Química Farmacêutica , Cromatografia Líquida/métodos , Pós
2.
J Pharm Biomed Anal ; 30(2): 175-80, 2002 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-12191701

RESUMO

A LC method has been developed for the quantitative determination of Oxiconazole (Ox) in bulk form, lotion and cream pharmaceutical formulations. The method validation yielded good results including the range, linearity, precision, accuracy, recovery, specificity, robustness, limit of quantitation and limit of detection. The LC separation was carried by reversed phase chromatography using a LiChrocart C(8) column (125 mm x 4.0 mm i.d., 5 microm particle size). The mobile phase was composed of methanol-0.02 M ammonium acetate buffer (85:15 v/v), pumped isocratically at flow rate 1 ml min(-1). The detection was carried out on UV detector at 254 nm. The calibration curve for Ox was linear from 40.0-140.0 microg ml(-1) range. The precision of this method, calculated as the relative standard deviation (R.S.D.) was 1.57% for lotion and 0.71% for cream. The R.S.D. values for intra- and inter-day precision studies were 0.57 and 1.34%, respectively. The recovery of the drug ranged between 98.84-102.2% (lotion) and 100.54-101.59% (cream). The stability indicating capability of the assays was proved using forced degradation. Chromatograms showed Ox well resolved from the degradation product.


Assuntos
Imidazóis/análise , Química Farmacêutica , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/estatística & dados numéricos , Imidazóis/química , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química
3.
J Pharm Biomed Anal ; 28(6): 1195-9, 2002 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-12049983

RESUMO

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method was developed for the assay of enrofloxacin in raw material and injection. The validation method yielded good results and included the range, linearity, precision, accuracy, specificity, recovery, limit of detection (LOD) and limit quantification (LOQ) values. The HPLC separation was carried out by reversed phase chromatography on a C-18 absorbosphere column (150 x 4.6 mm i.d. 5 microm particle size) with a phase composed of sodium acetate (pH 4.7; 0.1 M): acetonitrile (60:40, v/v; pH 5.0), pumped isocratically at a flow rate of 1.5 ml min(-1). The effluent was monitored at 278 nm with the eluting solvent. The calibration graph for enrofloxacin was linear from 10.0 to 80.0 microg ml(-1).


Assuntos
Anti-Infecciosos/análise , Cromatografia Líquida de Alta Pressão/métodos , Fluoroquinolonas , Quinolonas/análise , Enrofloxacina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...