Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Iran Endod J ; 18(4): 241-247, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37829838

RESUMO

Introduction: This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files. Material and Methods: Twenty mesiobuccal canals of mandibular molars were prepared using the 2Shape sequential rotary system. CBCT and micro-CT scans were performed before and after instrumentation, and the magnitude of transportation and centering ratio were measured. The acceptable transportation was set at ≤0.15 mm. The accuracy and agreement between CBCT and micro-CT were calculated, and the intra-class correlation coefficient (ICC) and kappa coefficient were determined to assess the agreement between the two modalities. Statistical analyses were performed using repeated measures ANOVA. Results: Transportation was detected by both modalities at all distances from the apex after instrumentation. The agreement between CBCT and micro-CT in assessing canal transportation was observed in 80%, 85%, 75%, and 75% of specimens at 1-, 3-, 5-, and 7-mm from the apex, respectively. The ICC for transportation and centering ratio was much lower than 0.75, indicating poor agreement between the modalities. The kappa coefficient did not show acceptable agreement between the methods. Conclusions: CBCT and micro-CT demonstrated poor agreement in assessing canal transportation and centering ratio. Micro-CT remains the preferred modality for in vitro investigations, while CBCT should be limited to clinical settings.

2.
Int J Dent ; 2021: 4898684, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34795762

RESUMO

AIMS: A glide path is created prior to root canal instrumentation by nickel-titanium (NiTi) rotary files to increase the efficiency and safety of cleaning and shaping. This study aimed to assess root canal transportation in use of different glide path files in curved canals. MATERIALS AND METHODS: 30 sound mesiobuccal root canals of mandibular molars with 20° to 40° curvature were selected and randomly assigned to 3 groups of EdgeGlidePath (EGP, EdgeEndo), One-G (Micro-Mega), and Neolix (Neoniti). The specimens were scanned before and after glide path creation by microcomputed tomography (micro-CT). The pre- and postoperative micro-CT scans were superimposed, and the degree of canal transportation and centering ratio were measured at 1, 3, 5, and 7 mm distances from the apical foramen. Statistical Analysis. The data were analyzed by two-way and one-way ANOVA. RESULTS: The effects of distance from the apical foramen and instrument type and the interaction effect of the two were not significant on the centering ability of the files or canal transportation. CONCLUSION: EdgeGlidePath, One-G, and Neolix files fabricated from the conventional NiTi alloy or heat-treated M-Wire alloy showed similar performance regarding centering ability and canal transportation in glide path preparation in curved canals.

3.
Dent Med Probl ; 58(4): 515-523, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34994116

RESUMO

BACKGROUND: Root canal preparation with nickel-titanium (NiTi) instruments may lead to the formation of microcracks in the root canal wall. Vertical root fractures may initiate from dentinal cracks, and eventually necessitate tooth extraction. OBJECTIVES: This study aimed to assess the effect of the instrumentation of curved root canals of mandibular molars with the 2Shape (2S) sequential rotary, EdgeFile® X1 (EFX1) reciprocating and NeoNiTi (NN) rotational single-file systems on the formation of dentinal microcracks with the use of micro-computed tomography (micro-CT). MATERIAL AND METHODS: Thirty curved mandibular molar root canals were instrumented with the 2S, EFX1 and NN systems (10 in each group). The teeth underwent micro-CT before and after instrumentation. Next, the pre-instrumentation and post-instrumentation cross-sectional images were evaluated and compared for the detection of dentinal microcracks. The number of microcracks in each group was calculated and reported as percentage. The data was analyzed using the McNemar's test with the IBM SPSS Statistics for Windows software, v. 25.0 (α = 0.05). RESULTS: Out of the 29,280 cross-sectional images evaluated in this study, 11.5% showed dentinal microcracks (n = 3,362). On the post-instrumentation images, the frequency percentage of microcracks was 12.0% (n = 585) in the 2S group, 8.8% (n = 402) in the EFX1 group and 13.3% (n = 694) in the NN group. All of the microcracks detected on the post-instrumentation images were also present on the preinstrumentation images and no new microcracks were formed after root canal instrumentation with the aforementioned systems. CONCLUSIONS: Root canal instrumentation with the 2S, EFX1 and NN systems did not result in the formation of new dentinal microcracks.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/cirurgia , Humanos , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Preparo de Canal Radicular/efeitos adversos , Raiz Dentária , Microtomografia por Raio-X
4.
Iran Endod J ; 15(3): 183-187, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-36703809

RESUMO

Introduction: This study aimed to assess the physical and chemical properties of an experimental endodontic resin sealer (Resil) compared with AH-26 and AH-Plus. Methods and Materials: In this in vitro experimental study, dimensional stability (by measurement of length; n=5), pH (using a pH meter; n=5), and antibacterial activity (by agar diffusion test; n=8) of Resil, AH-26 and AH-Plus were evaluated and compared using one-way ANOVA and Tukey's test. Results: All three groups showed significant expansion from day 1 to day 30 (P<0.05). The difference in the mean dimensional changes between the AH-Plus and experimental sealer was significant (P=0.020). Two hours after mixing, the pH of experimental sealer (Resil) was significantly lower than that of AH-Plus (P<0.001) and higher than that of AH-26 (P<0.001). Antibacterial activity of the experimental sealer before and after setting was significantly higher than that of the other two sealers (P<0.001). Conclusion: The results of this in vitro study showed that the experimental sealer had greater 1 to 30 days dimensional changes than the other two sealers. It had an alkaline pH, and showed superior antibacterial activity compared with AH-26 and AH-Plus. It may be possible to use this sealer in the clinic after animal studies because an epoxy resin based sealer with lower price and more appropriate properties is favorable.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...