Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 143(11): 6919-6926, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37392216

RESUMO

INTRODUCTION: The purpose of this study was to report mid-term clinical and radiographic results after hip arthroplasty revision in Vancouver type B2 femoral periprosthetic fractures (PPFx). Specifical focus of the paper is as follows: (1) the description of a standardized and reproducible surgical technique, (2) functional outcomes presentation and (3) type and number of complications and implants' survival rate analysis. METHODS: We retrospectively reviewed all patients treated for hip revision with non-modular tapered fluted titanium stem in patients with Vancouver type B2 femur PPFx at a single institution. At least 18 months' follow-up period was required. Harris Hip Scores and SF-12 were obtained, and radiographical follow-up was performed. Complications were reported and analyzed. RESULTS: The authors included 114 patients (114 hips) with a mean follow-up of 62.8 ± 30.6 months. All patients were treated with Wagner SL revision hip stem (Zimmer-Biomet), metal cerclage wires ± trochanteric plate. The mean HHS and SF-12 score at the last follow-up evaluation were respectively 81.3 ± 9.7 and 32.5 ± 7.6. Seventeen (14.9%) complications occurred. We observed five cases of dislocations, two of periprosthetic joint infections and six cases of new PPFx. The stem-related revision rate for any cause at the final FU was 1.7%, due to PJI. No patients underwent stem revision surgery for aseptic loosening. Fracture healed in all the included patients with a union-rate of 100%. The re-operation rate for any cause was 9.6%, with an implant survival rate for overall failure of 96.5%. CONCLUSION: The presented standard and reproducible surgical technique obtains optimal clinical and radiological results with limited complication rate at mid-term follow up. Preoperative planning as well as careful intraoperative surgical technique is of a paramount importance.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Estudos Retrospectivos , Centros de Atenção Terciária , Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Reoperação/métodos , Desenho de Prótese , Resultado do Tratamento
2.
Hip Int ; 33(4): 664-671, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35465751

RESUMO

OBJECTIVE: The primary aim was to evaluate the long-term follow-up of Collum Femoris Preserving (CFP) stem, specifically focusing on stem survivorship, complications, as well as on clinical and radiological results. The secondary study objective is an age-based sub-analysis (<65 years vs. ⩾65 years) of long-term results. MATERIALS AND METHODS: We performed a retrospective analysis of patients who underwent CFP implantation between 1997 and 2009. A total of 311 patients (342 hips) were included with a mean follow-up of 15.8 ± 2.2 (range 11-24) years. 2 age groups were analysed: Group-Y (age <65) and Group-E (age ⩾65). Group-Y included 182 hips (mean follow-up 16.3 ± 4.2 years), whereas Group-E included 160 hips (mean follow-up 15.5 ± 3.7 years). Clinical (HHS, OHS and VAS) and radiological data were obtained at final follow-up. Any complications, reoperations, prosthetic components revisions and stem revisions were analysed. RESULTS: According to HSS score, 95% of patients reported excellent/good results (95.6% Group-Y vs. 94.4% Group-E) with an overall stem survival rate of 93.3% (94% Group-Y vs. 92.5% Group-E; p = 0.37). Overall, 87% of stem revisions were performed with primary stems. The rate of prosthetic components revision was 9.9 % (9.9% in Group-Y vs. 10% in Group-E; p = 1). The reoperation rate was 10.8% (11.5% in Group-Y vs. 10.0% in Group-E; p = 0.73). CONCLUSIONS: The CFP stem provides good clinical and radiological long-term results with low rate of complications in both young and elderly patients. No significant difference in stem revision and reoperation rates was observed between the 2 groups. Both in elderly and young patients, CFP stem allows revisions to be performed with primary stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Colo do Fêmur/cirurgia , Articulação do Quadril/cirurgia , Reoperação , Seguimentos , Desenho de Prótese , Resultado do Tratamento , Falha de Prótese
3.
Arch Orthop Trauma Surg ; 142(8): 2031-2038, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35589980

RESUMO

INTRODUCTION: Unicompartmental knee arthroplasty (UKA) has an infection rate of 0.1-0.8%. Despite the wide amount of literature about septic total knee arthroplasty management, few data are available for UKA infection treatment. The aim is to present the clinical and radiological outcomes along with complication rates of a series of septic UKA treated with two-stage exchange. METHODS: We retrospectively reviewed 16 patient treated with staged UKA revision for infection between June 2015 and September 2019 in a single bone infection unit. The main demographic and surgical data were recorded. Clinical scores (VAS, KSS, OKS, postoperative ROM), radiological parameters (osseointegration, loosening and radiolucencies) and complications were reported. The mean follow-up was 33.5 ± 6.9 months. RESULTS: Mean age at surgery was 68.5 ± 9.1. All but two were medial UKA. The mean number of previous surgeries was 2.9 ± 1.9. The mean ROM, VAS, KSS and OKS of the entire population improved significantly (p < 0.01). Radiological analysis did not show any migration or implant loosening. Ten constrained condylar and six posterior stabilized prosthesis were finally implanted. One intraoperative pathogen isolation was recorded and managed with suppressive therapy and good final outcome. The implant survivorship free from infection was 100% at the final follow-up. The overall survival rate for any reason of revision was 100% CONCLUSION: According to our results, staged revision represents a reliable ad effective option in delayed and late UKA infections. This technique provides optimal clinical and radiological results with acceptable complication rates. To the best of our knowledge, this represent the widest case series on infected UKA managed with two-stage exchange.


Assuntos
Artrite Infecciosa , Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Infecções Relacionadas à Prótese , Artrite Infecciosa/cirurgia , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
4.
Hip Int ; 30(1_suppl): 12-18, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32907429

RESUMO

BACKGROUND: The management of acetabular bone loss is a challenging problem in revision total hip arthroplasty (rTHA). The goals of treatment are a stable acetabular fixation, implant stability, and restoration of hip centre of rotation.This study aims to report clinical, radiological outcomes and complications at short-term to mid-term follow-up of the cup-on-cup technique in the management of severe acetabular bone loss in rTHA. METHODS: We retrospectively reviewed the records of patient receiving rTHA performed with double porous tantalum cup technique in a single Joint Replacement Unit from 2014 to 2017. Objective and subjective clinical scores (Harris Hip Score, Oxford Hip Score, and visual analogue scale), radiological parameters (centre of rotation, leg-length discrepancy, heterotopic ossification, osseointegration, loosening and radiolucencies) and complications were recorded. We analysed the implant survival rate and periprosthetic joint infection rate. RESULTS: We included 9 patients (9 hips) with a mean follow-up of 35.3 ± 10.8 months. Functional scores showed a statistically significant improvement at the final follow-up (p < 0.01). All patients rated their surgery as satisfactory. The cup-on-cup construct demonstrated radiological osseointegration with the centre of rotation restoration and leg length discrepancy improvement. In 1 patient, periprosthetic joint infection was diagnosed and treated with suppressive antibiotic therapy. No patients underwent acetabular components revision surgery for any reason. CONCLUSIONS: Cup-on-cup technique is a valid and safe solution for reconstruction of selected Paprosky type IIIA and IIIB bone defects with satisfactory clinical and radiographic results at short-term and mid-term follow-up.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Reabsorção Óssea/cirurgia , Prótese de Quadril , Reoperação/métodos , Idoso , Idoso de 80 Anos ou mais , Reabsorção Óssea/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Falha de Prótese , Radiografia , Estudos Retrospectivos , Tantálio
5.
HSS J ; 16(2): 143-154, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32523482

RESUMO

BACKGROUND: In the past decade, lateral lumbar interbody fusion (LLIF) has gained in popularity. A proposed advantage is the achievement of indirect neural decompression. However, evidence of the effectiveness of LLIF in neural decompression in lumbar degenerative conditions remains unclear. QUESTIONS/PURPOSES: We sought to extrapolate clinical and radiological results and consequently the potential benefits and limitations of LLIF in indirect neural decompression in degenerative lumbar diseases. METHODS: We conducted a systematic review of the literature in English using the 2009 Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and checklist. Scores on the Oswestry Disability Index (ODI) and visual analog scale (VAS) for back and leg pain were extracted, as were data on the following radiological measurements: disc height (DH), foraminal height (FH), foraminal area (FA), central canal area (CA). RESULTS: In the 42 articles included, data on 2445 patients (3779 levels treated) with a mean follow-up of 14.8 ± 5.9 months were analyzed. Mean improvements in VAS back, VAS leg, and ODI scale scores were 4.1 ± 2.5, 3.9 ± 2.2, and 21.9 ± 7.2, respectively. Post-operative DH, FH, FA, and CA measurements increased by 68.6%, 21.9%, 37.7%, and 29.3%, respectively. CONCLUSION: Clinical results indicate LLIF as an efficient technique in indirect neural decompression. Analysis of radiological data demonstrates the effectiveness of symmetrical foraminal decompression. Data regarding indirect decompression of central canal and lateral recess are inconclusive and contradictory. Bony stenosis appears as an absolute contraindication. The role of facet joint degeneration is unclear. This systematic review provides a reference for surgeons to define the potential and limitations of LLIF in indirect neural elements decompression.

6.
Int Orthop ; 44(10): 1957-1964, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32542450

RESUMO

PURPOSE: Acetabular bone loss is a challenging problem in revision total hip arthroplasty (rTHA). Severe bone loss is not uncommon especially in periprosthetic joint infection. Surgical options, including revision shells, rings, and cages-with or without bone allograft-are affected by high complication rates and unsatisfactory clinical results. We report our mid-term results of non-flanged, custom-made acetabular components in staged rTHA. METHODS: We retrospectively reviewed all patients undergoing two-stage revision with acetabular custom-made implants between 2014 and 2016 at a single institution. Harris Hip Scores, Oxford Hip Scores, and Visual Analogue Scales for pain were obtained, and radiographical follow-up was performed. Complications were reported and analysed. RESULTS: We included 19 patients (19 hips) with an average follow-up of 42.3 ± 11.8 months. At the time of re-implantation, significant acetabular bone loss according to Paprosky classification (IIC, IIIA-B, and pelvic discontinuity) was detected in our patients. Clinical outcomes showed statistically significant improvement from pre-operative visit to last follow-up (p < 0.01). All custom-made implants had radiological osseointegration, and we did not find any implant complications, such as loosening or malposition. No mismatch between pre-operative planning and intra-operative findings was observed. To date, we report one septic failure managed with second staged revision, and one re-operation for recurrent THA dislocation. CONCLUSIONS: Custom-made acetabular implants showed excellent clinical and radiographic mid-term outcomes with a low rate of related complications, providing implant stability on residual host bone, restoring hip biomechanics, and allowing biological osseointegration. Further long-term studies are needed to confirm preliminary results.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Porosidade , Falha de Prótese , Reoperação , Estudos Retrospectivos , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...