Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
JTCVS Tech ; 22: 150-158, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152173

RESUMO

Objectives: This study analyzes neocommissural alignment and the clinical and hemodynamic outcomes after transaxillary and transcarotid implantation of the Acurate neo2 transcatheter heart valve. Methods: We performed a retrospective, single-center analysis of early outcomes after transaxillary and transcarotid implantation of the Acurate neo2 transcatheter heart valve. Primary outcomes were neocommisural alignment, in-hospital mortality, and valve hemodynamic performance. Commissural alignment between native and transcatheter heart valves was assessed by transesophageal echocardiogram before and after the procedure. Results: Between October 2021 and November 2022, 40 consecutive patients were treated with the Acurate neo2 through a transaxillary or transcarotid approach. Access was achieved via the left subclavian artery in 30 cases and the left common carotid artery in 10 cases, with a mean vessel diameter of 6.7 mm. Implants most commonly used were size M (37.5%), L (35%), and S (27.5%). On the basis of transesophageal echocardiogram analysis, there was no significant difference in mean commissural orientation between native (mean, 65.1°; SD, 41.3°) and neocommissures (mean, 64°; SD, 44.1°) (P = .661). Mean commissural orientation did not significantly differ between native and neocommissures (P = .661). Optimal alignment or mild commissural misalignment was achieved in 99.5% of cases. There were no cases of severe commissural misalignment. Postprocedural mean values for peak and mean gradients were 12.7 mm Hg and 5.2 mm Hg, respectively. There were 2 cases of moderate paravalvular leak and 4 cases of mild paravalvular leak. Conclusions: This patient-specific technique for transaxillary and transcarotid insertion of the Acurate neo2 delivery system prevents implantations with more than mild commissural misalignment and with a high device success rate.

2.
Pharmaceutics ; 14(2)2022 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-35213991

RESUMO

Atherosclerosis is an underlying risk factor in cardiovascular diseases (CVDs). The combination of drugs with microRNAs (miRNA) inside a single nanocarrier has emerged as a promising anti-atherosclerosis strategy to achieve the exploitation of their complementary mechanisms of action to achieve synergistic therapeutic effects while avoiding some of the drawbacks associated with current systemic statin therapies. We report the development of nanometer-sized polymeric PLGA nanoparticles (NPs) capable of simultaneously encapsulating and delivering miRNA-124a and the statin atorvastatin (ATOR). The polymeric NPs were functionalized with an antibody able to bind to the vascular adhesion molecule-1 (VCAM1) overexpressed in the inflamed arterial endothelium. The dual-loaded NPs were non-toxic to cells in a large range of concentrations, successfully attached overexpressed VCAM receptors and released the cargoes in a sustainable manner inside cells. The combination of both ATOR and miRNA drastically reduced the levels of proinflammatory cytokines such as IL-6 and TNF-α and of reactive oxygen species (ROS) in LPS-activated macrophages and vessel endothelial cells. In addition, dual-loaded NPs precluded the accumulation of low-density lipoproteins (LdL) inside macrophages as well as morphology changes to a greater extent than in single-loaded NPs. The reported findings validate the present NPs as suitable delivery vectors capable of simultaneously targeting inflamed cells in atherosclerosis and providing an efficient approach to combination nanomedicines.

3.
Interact Cardiovasc Thorac Surg ; 33(2): 195-202, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-33792711

RESUMO

OBJECTIVES: This study aims to evaluate the efficacy, safety and long-term outcomes of a renoprotective non-contrast, transoesophageal echocardiography-guided transapical (TA) transcatheter aortic valve replacement (TAVR) strategy with a balloon-expandable prosthesis, as well as to determine its impact on renal function. METHODS: Between 2009 and 2019, 200 consecutive patients underwent a non-contrast, transoesophageal echocardiography-guided TA TAVR with a balloon-expandable prosthesis. RESULTS: The device success rate was 95.5%. Transoesophageal echocardiography-guided deployment demonstrated a low rate of procedure-related complications: 9.5% of acute kidney injury, 8% postoperative bleeding, 6% low-cardiac output, 4.5% postprocedural aortic regurgitation ≥+2, 4% implantation of permanent pacemaker and 2% stroke. There were no significant differences between preoperative and on discharge estimated glomerular filtration rate (53.9 ± 22.2 vs 54.3 ± 22.9 ml/min/1.73 m2, P = 0.60). Logistic regression analysis confirmed postoperative bleeding as an independent predictor for acute kidney injury (odds ratio (OR) 11.148, 95% confidence interval 3.537-35.140, P < 0.001). In-hospital mortality was 7.5%. The mean follow-up was 48.5 ± 39.9 months. Renal function and patient's chronic kidney disease stage did not significantly vary during follow-up. Long-term cumulative survival at 1, 5 and 10 years was 84.2 ± 0.027%, 42.9 ± 0.038% and 32.5 ± 0.044%, respectively. Renal function affected on neither in-hospital mortality nor long-term survival. CONCLUSIONS: Non-contrast, transoesophageal echocardiography-guided TA TAVR is a safe and reproducible technique with a low incidence of periprocedural complications that avoids the use of contrast and mitigates the incidence of acute kidney injury.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Interact Cardiovasc Thorac Surg ; 33(2): 173-180, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-33782703

RESUMO

OBJECTIVES: This study aims to analyse the risks associated with valve-in-valve procedures for treating structural valve deterioration in Mitroflow bioprostheses, as well as to determine the impact of the original Mitroflow size on the patients' long-term outcomes. METHODS: Between January 2012 and September 2019, 21 patients (61.9% males; mean age 82.4 ± 5.4 years) were treated for Mitroflow deterioration with valve-in-valve procedures (12 transapical and 9 transfemoral). RESULTS: Mean EuroSCORE I and EuroSCORE II were 28.2% ± 13.6% and 10.5% ± 6.1%, respectively. Six patients presented an indexed aortic root diameter <14 mm/m2 and 7 patients a diameter of sinus of Valsalva <30 mm. Implanted transcatheter valve sizes were 20 mm in 6 cases, 23 mm in 14 cases and 26 mm in 1 patient. A Valve Academic Research Consortium-2 complication occurred in 23.8% of cases, including 3 coronary occlusions. In-hospital mortality was 9.5%. The 20 mm transcatheter valves presented significantly higher postoperative peak and mean aortic gradients than other sizes (54.1 ± 11.3 mmHg vs 29.9 ± 9.6 mmHg, P = 0.003; and 29.3 ± 7.7 mmHg vs 17.4 ± 5.9 mmHg, P = 0.015, respectively). There were 12 cases of patient-prosthesis mismatch (57.1%) and 3 cases (14.3%) of severe patient-prosthesis mismatch. Cumulative survival was 85.7% ± 7.6% at 1 year, 74.3% ± 10% at 2 years and 37.1% ± 14.1% at 5 years. CONCLUSIONS: Valve-in-valve procedures with balloon-expandable transcatheter valves associate a high risk of coronary occlusion in patients with indexed aortic root diameter <14 mm/m2 and low coronary ostia <12 mm. Valve-in valve procedures with 20 mm balloon-expandable transcatheter valves in ≤21 mm Mitroflow bioprosthesis leave significant residual transvalvular gradients that might obscure patients' long-term outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Fluoroscopia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Mol Pharm ; 16(8): 3374-3385, 2019 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-31188622

RESUMO

The administration of small interfering RNA (siRNA) is a very interesting therapeutic option to treat genetic diseases such as Alzheimer's or some types of cancer, but its effective delivery still remains a challenge. Herein, Au nanorod (GNR)-based platforms functionalized with polyelectrolyte layers were developed and analyzed as potential siRNA nanocarriers. The polymeric layers were successfully assembled on the particle surfaces by means of the layer-by-layer assembly technique through the alternating deposition of oppositely charged poly(styrene)sulfonate, PSS, poly(lysine), PLL, and siRNA biopolymers, with a final hyaluronic acid layer in order to provide the nanoconstructs with a potential targeting ability as well as colloidal stability in physiological medium. Once the hybrid nanocarriers were obtained, the cargo release, their colloidal stability in physiological-relevant media, cytotoxicity, cellular internalization and uptake, and knockdown activity were studied. The present hybrid particles release the genetic material inside cells by means of a protease-assisted and/or a light-triggered release mechanism in order to control the delivery of the oligonucleotides on demand. In addition, the hybrid nanovectors were observed to be nontoxic to cells and could efficiently deliver the genetic material in the cell cytoplasms. The GNR-based nanocarriers proposed here can provide a suitable environment to load and protect a sufficient amount of the genetic material to allow an efficient and sustained knockdown gene expression for long (up to 93% for 72 h), thanks to the slow degradation of PLL, without the observation of adverse side toxic effects. It was also found that the silencing activity was enhanced with the number of siRNA layers assembled in the nanoplatforms.


Assuntos
Portadores de Fármacos/química , Nanopartículas Metálicas/química , Neoplasias/terapia , RNA Interferente Pequeno/administração & dosagem , Terapêutica com RNAi/métodos , Técnicas de Silenciamento de Genes , Genes Reporter/genética , Ouro/química , Proteínas de Fluorescência Verde/genética , Células HeLa , Humanos , Nanotubos/química , Neoplasias/genética , Polilisina/química , Poliestirenos , RNA Interferente Pequeno/genética
6.
ACS Omega ; 3(10): 12633-12647, 2018 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-30411014

RESUMO

In this work, multifunctional nanocarriers consisting of poly(sodium-4-styrenesulfonate) (PSS)/doxorubicin (DOXO)/poly-l-lysine hydrobromide (PLL)/hyaluronic acid (HA)-coated and (PSS/DOXO/PLL)2/HA-coated gold nanorods were assembled by the layer-by-layer technique with the aims of coupling the plasmonic photothermal properties of the metal nanoparticles for plasmonic hyperthermia and the chemoaction of drug DOXO for potential intended combinatorial cancer therapeutics in the future as well as providing different strategies for the controlled and sustained release of the cargo drug molecules. To do that, DOXO could be successfully loaded onto the hybrid nanoconstructs through electrostatic interactions with high efficiencies of up to ca. 78.3 ± 6.9% for the first formed drug layer and 56 ± 13% for the second one, with a total efficiency for the whole system [(PSS/DOXO/PLL)2/HA-coated NRs] of ca. 65.7 ± 1.4%. Nanohybrid internalization was observed to be enhanced by the outer HA layer, which is able to target the CD44 receptors widely overexpressed in some types of cancers as lung, breast, or ovarian ones. Hence, these nanohybrid systems might be versatile nanoplatforms to simultaneously deliver sufficient heat for therapeutic plasmonic hyperthermia and the anticancer drug. Two controlled mechanisms were proposed to modulate the release of the chemodrug, one by means of the enzymatic degradable character of the PLL layer and another by the modulation of the interactions between the polymeric layers through the exploitation of the optical properties of the hybrid particles under near infrared (NIR) laser irradiation. The combination of this bimodal therapeutic approach exerted a synergistic cytotoxic effect on both HeLa and MDA-MB-231 cancer cells in vitro. Cell death mechanisms were also analyzed, elucidating that plasmonic photothermal therapy induces cell necrosis, whereas DOXO activates the cell apoptotic pathway. Therefore, the present NIR laser-induced targeted cancer thermo/chemotherapy represents a novel targeted anticancer strategy with easy control on demand and suitable therapeutic efficacy.

7.
J Card Surg ; 33(7): 356-362, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29790206

RESUMO

OBJECTIVES: Bioprostheses with pericardial leaflets mounted externally on the stent pose a high risk for valve-in-valve (ViV) procedures. This study analyzed the efficacy and safety of ViV procedures for treating structural valve deterioration (SVD) in Mitroflow bioprostheses. METHODS: Between January 2012 and August 2017, 11 patients (mean age 80.3 ± 5.6 years) were treated for SVD of Mitroflow bioprostheses with transcatheter ViV procedures (six transapical [TA] and five transfemoral [TF]) using balloon expandable bioprostheses. RESULTS: All patients but one were in NYHA class III-IV. Mean STS PROM, euroSCORE I, and euroSCORE II were 8 ± 6.5%, 27.8 ± 11.5%, and 12 ± 5.9%, respectively. Two patients had a "porcelain aorta." The size of implanted valves were 23 mm in 10 cases and 26 mm in one case. One patient suffered a coronary occlusion during a TF approach. The mean volume of contrast used in TF implants was 163 ± 69.8 mL. No contrast media were used in TA procedures. There was one in-hospital death (10%). At 1 year of follow-up, peak and mean aortic gradients were 25.5 ± 5.8 mmHg and 15.5 ± 5.7 mmHg, respectively. One patient had mild paravalvular regurgitation. Cumulative survival was 90.9% at 1 year, 70.7% at 2 years, and 53% at 3 years. CONCLUSIONS: ViV procedures with balloon-expandable aortic valves provide good hemodynamic and clinical mid-term results for treating patients with a degenerated Mitroflow aortic bioprosthesis. Special care must be taken in small aortic roots, when the stented valve is in the supra-annular position to avoid coronary ostial obstruction.


Assuntos
Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Segurança , Stents , Resultado do Tratamento
8.
Eur J Cardiothorac Surg ; 54(4): 689-695, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29659806

RESUMO

OBJECTIVES: The objective of this study is to compare early and long-term results in terms of survival and aortic complications for traumatic aortic injuries depending on the initial management strategy. METHODS: From January 1980 to January 2017, 101 patients with aortic injuries were divided into 3 groups according to management strategy at admission: 60 patients, conservative management; 26 patients, open surgery and 15 patients, endovascular repair. The groups were similar in terms of gender and trauma severity scores. RESULTS: All but 1 aortic-related complications and aortic-related mortality occurred in the conservative group (11.6% conservative vs 2.4% in both surgical and endovascular groups, P = 0.091). Total follow-up was 1109.27 patient-years. Survival in the conservative, surgical and endovascular group was 71.7%, 80.8% and 79.4% at 1 year, 68.2%, 80.8% and 79.4% at 5 years and 63.9%, 72.7% and 79.4% at 10 years, respectively (log-rank = 0.218). The rate of aortic-related complications was 58.3% in the conservative cohort. Cox regression identified the following risk factors for aortic-related complications: aortic injuries grade >I [odds ratio (OR), 3.05; P = 0.021], Trauma Injury Severity Score >50% (OR 1.21; P = 0.042) and the decade of treatment (OR 0.49; P = 0.011). CONCLUSIONS: Minimal aortic injuries seem to be an amenable target for medical management, but patients remain at risk of developing aortic-related complications. Close, long-term imaging surveillance is mandatory to detect such complications at an early stage.


Assuntos
Aorta/lesões , Tratamento Conservador/métodos , Gerenciamento Clínico , Lesões do Sistema Vascular/terapia , Ferimentos não Penetrantes/terapia , Doença Aguda , Adulto , Aortografia , Feminino , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico , Lesões do Sistema Vascular/mortalidade , Ferimentos não Penetrantes/diagnóstico
9.
Eur J Emerg Med ; 25(3): 178-184, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28027073

RESUMO

OBJECTIVE: To assess the value of the pretest probability (PTP) of coronary artery disease (CAD) for predicting stress testing results and coronary events in patients with acute chest pain and negative troponins. PATIENTS AND METHODS: A total of 3527 patients without a history of CAD referred to our chest pain unit with suspected acute coronary syndromes, nondiagnostic ECGs, and negative troponin levels underwent exercise stress testing. PTP was estimated with the CAD consortium prediction rule, and was categorized as low (<15%), low-intermediate (15-65%), intermediate-high (66-85%), and high (>85%). The endpoints were the presence of signs of inducible myocardial ischemia on stress testing and the occurrence of coronary events within 6 months. RESULTS: The probability of exercise-induced myocardial ischemia was 2.6, 12.6, 42.9, and 82.1% in patients with low, low-intermediate, intermediate-high, and high PTP, respectively (Ptrend<0.001). The cumulative rate of coronary events within 6 months was also significantly lower in patients with low PTP of CAD (0.8%) than in those with low-intermediate (6.9%), intermediate-high (32.5%), or high PTP (66.7%) (Ptrend<0.001). Per 10% increment in PTP of CAD, the adjusted odds ratios for inducible myocardial ischemia and coronary events within 6 months were, respectively, 1.71 (95% confidence interval: 1.61-1.85) and 1.87 (95% confidence interval: 1.74-2.01). CONCLUSION: PTP was associated strongly with the likelihood of exercise-induced myocardial ischemia and coronary events in patients with suspected acute coronary syndromes and negative troponins. The yield of stress testing in the subset of patients with low PTP was very low.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Dor no Peito/etiologia , Doença da Artéria Coronariana/diagnóstico , Teste de Esforço/estatística & dados numéricos , Troponina I/sangue , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/complicações , Idoso , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/complicações , Técnicas de Apoio para a Decisão , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Estudos Prospectivos
10.
Eur Heart J Acute Cardiovasc Care ; 7(7): 602-608, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28029052

RESUMO

BACKGROUND: Recent advances in the diagnosis and treatment of acute aortic syndrome should improve the outcome of this disease. The Spanish Registry of Acute Aortic Syndrome aimed to assess current results in acute aortic syndrome management in a wide cohort of hospitals in the same geographical area. METHODS: From January 2012 to January 2014, 26 tertiary hospitals included 629 consecutive patients with acute aortic syndrome: 73% men, mean age 64.7±14 years (range 22-92), 443 type A (70.4%) and 186 type B (29.6%). RESULTS: Time elapsed between symptom onset and diagnosis was <12 hours in 70.7% of cases and <24 hours in 84.0% (median 5 hours; 25th-75th percentiles, 2.7-15.5 hours). Computed tomography was the first diagnostic technique in 78% of patients and transthoracic echocardiography in 15%. Surgical treatment was indicated in 78.3% of type A acute aortic syndrome. The interval between diagnosis and surgery was 4.8 hours (quartile 1-3, 2.5-11.4 hours). Among the patients with type B acute aortic syndrome, treatment was medical in 116 cases (62.4%), endovascular in 61 (32.8%) and surgical in nine (4.8%). Type A mortality during hospitalisation was 25.1% in patients treated surgically and 68% in those treated medically. Mortality in type B was 13.8% in those with medical treatment, 18.0% with endovascular therapy and 33.0% with surgical treatment. CONCLUSION: Improvements in the diagnosis and treatment of acute aortic syndrome have not resulted in a significant reduction in hospital mortality. The results of this study reflect more overall and less selected information on acute aortic syndrome management and the need for sustained advances in the therapeutic strategy of acute aortic syndrome.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico , Dissecção Aórtica/diagnóstico , Procedimentos Endovasculares/métodos , Sistema de Registros , Stents , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/mortalidade , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/cirurgia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Síndrome , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
12.
J Thorac Cardiovasc Surg ; 153(6): 1275-1284.e7, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28291607

RESUMO

OBJECTIVES: The enlargement of the left atrium has been identified as a marker of chronically increased left ventricular filling pressure and left ventricular diastolic dysfunction. This study aims to evaluate the association of indexed left atrial diameter with stroke, cardiovascular mortality, the combined event, and all-cause mortality in patients who underwent aortic valve surgery. METHODS: Indexed left atrial diameter was measured in 2011 adult patients (mean age, 70.9 ± 10.8 years; 58.7% were men) who underwent aortic valve surgery between January 2008 and March 2016. RESULTS: On the basis of the criteria of the American Society of Echocardiography, indexed left atrial diameter was normal in 64% of patients, mildly enlarged in 12.4% of patients, moderately enlarged in 9.2% of patients, and severely enlarged in 14.3% of patients. Over a mean follow-up period of 3.2 ± 2.1 years, there were 334 deaths and 97 strokes. Cardiovascular mortality survival at 5 years among patients with normal, mild, moderate, and severe left atrial enlargement was 91.6%, 86.8%, 77.9%, and 77.4%, respectively (P < .001). After covariable adjustment, Cox regression analysis showed indexed left atrial diameter as an independent predictor of all-cause mortality (hazard ratio per 1-cm/m2 increment, 1.545; 95% confidence interval, 1.252-1.906, P < .001), cardiovascular death (hazard ratio per 1-cm/m2 increment, 1.971; 95% confidence interval, 1.541-2.520; P < .001), and the combined event (hazard ratio per 1-cm/m2 increment, 1.673; 95% confidence interval, 1.321-2.119; P < .001). CONCLUSIONS: Indexed left atrial diameter is a strong predictor of long-term outcomes in patients with aortic valve diseases who undergo surgery.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Função do Átrio Esquerdo , Remodelamento Atrial , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
J Card Surg ; 31(5): 264-73, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26991888

RESUMO

BACKGROUND: This study aims to determine the incidence and causes of structural valve deterioration (SVD) among all models of Mitroflow bioprostheses (A12/LX/DL), as well as to define their long-term clinical and hemodynamic performance. METHODS AND RESULTS: We retrospectively reviewed a series of 1023 patients who underwent aortic valve replacement with Mitroflow bioprostheses between 2001 and 2014. A small aortic root was found in 22.4% of patients. There were two cases of severe patient-prosthesis mismatch. Only 31 patients developed SVD. The rate of incidence was 8.1 cases per 1000 patient-years. Cumulative incidence of SVD was 1.4% and 3% at five and 10 years, respectively. Freedom from SVD was 97.4% and 88.2% at five and 10 years, respectively. Anticalcification phospholipid reduction treatment (PRT) for model DL was a protective factor for SVD. Multivariable analysis confirmed age <70 years and use of 19 mm valve as independent predictors of SVD. Cumulative survival was 76.6% at five years and 42.3% at 10 years (mean follow-up 3.8 ± 3.1 years). In multivariable analysis, neither the use of small aortic prosthesis (p = 0.18) nor the occurrence of SVD (p = 0.85) was found to be independent predictors of long-term survival. CONCLUSIONS: Mitroflow valves demonstrate an acceptable rate of SVD and satisfactory long-term hemodynamic performance, particularly in patients with small aortic roots, age >70 years, and cases with severe left ventricular hypertrophy. PRT might contribute to improved long-term durability. doi: 10.1111/jocs.12726 (J Card Surg 2016;31:264-273).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Teste de Materiais , Complicações Pós-Operatórias/epidemiologia , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Espanha/epidemiologia , Fatores de Tempo
15.
J Card Surg ; 31(3): 164-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26786056

RESUMO

One of the most feared complications of thoracic endovascular aortic repair (TEVAR) and hybrid arch repair is retrograde type A aortic dissection (RTAD). More than two-thirds of RTAD occurs in the immediate postoperative period and first postoperative month. In presentations beyond that point, progression of the native aortopathy must be considered. We report a late presentation of an RTAD seven months after hybrid repair of an aortic intramural hematoma with an ulcer-like projection, and review the causes and management of this TEVAR complication.


Assuntos
Aorta Torácica/cirurgia , Aneurisma Aórtico/etiologia , Dissecção Aórtica/etiologia , Procedimentos Endovasculares , Hematoma/cirurgia , Complicações Pós-Operatórias/etiologia , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma Aórtico/cirurgia , Progressão da Doença , Feminino , Humanos , Tomografia Computadorizada Multidetectores , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Período Pós-Operatório , Fatores de Tempo
16.
Eur J Intern Med ; 26(10): 787-91, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26388254

RESUMO

INTRODUCTION: Scarce data are available on the temporal patterns in clinical characteristics and outcomes of elderly patients referred for exercise stress testing. We aimed to assess the trends in baseline characteristics, tests results, referrals for invasive management, and mortality in these patients. METHODS: We evaluated 11,192 patients aged ≥65years who were referred for exercise stress testing between January 1998 and December 2013. Calendar years were grouped into four quadrennia (1998-2001, 2002-2005, 2006-2009, and 2010-2013), and trends in clinical characteristics of the patients, type and results of the tests, referrals for invasive management, and mortality across the different periods were assessed. RESULTS: Despite a progressive decrease in the proportion of patients with non-interpretable baseline electrocardiograms or prior history of coronary artery disease, there was a gradual and marked increase in the use of cardiac imaging from 32.8% in 1998-2001 to 67.6% in 2010-2013 (p<0.001). In addition, despite a gradual decline in the probability of positive exercise stress testing both without imaging (from 18.9 to 13.6%, p<0.001) and with imaging assessment (from 40.2 to 29.7%, p<0.001), the cumulative rate of coronary revascularization at 1year increased (from 10.8 to 13.7%, p<0.001). One-year mortality also decreased progressively from 3% to 1.6% (p<0.001). CONCLUSIONS: Among older adults referred for exercise stress testing, we observed a decline over time in the probability of inducible myocardial ischemia, an increase in the use of cardiac imaging and in the rate of coronary revascularization, and an improvement in the survival rate at 1year.


Assuntos
Técnicas de Imagem Cardíaca , Doença da Artéria Coronariana , Teste de Esforço , Revascularização Miocárdica , Encaminhamento e Consulta , Idoso , Técnicas de Imagem Cardíaca/métodos , Técnicas de Imagem Cardíaca/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Gerenciamento Clínico , Teste de Esforço/métodos , Teste de Esforço/estatística & dados numéricos , Feminino , Humanos , Masculino , Mortalidade/tendências , Revascularização Miocárdica/métodos , Revascularização Miocárdica/estatística & dados numéricos , Revascularização Miocárdica/tendências , Encaminhamento e Consulta/estatística & dados numéricos , Encaminhamento e Consulta/tendências , Estudos Retrospectivos , Medição de Risco/métodos , Índice de Gravidade de Doença , Espanha/epidemiologia , Fatores de Tempo
17.
Eur J Intern Med ; 26(9): 720-5, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26321649

RESUMO

BACKGROUND: Limited data are available on the added value of exercise echocardiography (ExEcho) over exercise electrocardiography (ExECG) in patients with suspected acute coronary syndromes (ACS) referred to a chest pain unit. We aimed to assess the incremental value of ExEcho over ExECG in this setting. METHODS: ExECG and ExEcho were performed in parallel in 1052 patients with suspected ACS, nondiagnostic but interpretable electrocardiograms, and negative serial troponin results. The primary outcome was a composite of coronary death, nonfatal myocardial infarction or unstable angina with angiographic documentation of significant coronary artery disease within 6 months. RESULTS: The primary outcome occurred in 2/614 patients (0.3%) with both negative ExECG and ExEcho, 3/60 (5%) with positive ExECG and negative ExEcho, 73/135 (54.1%) with negative ExECG and positive ExEcho, 106/136 (77.9%) with both positive ExECG and ExEcho, and 8/107 (7.5%) with inconclusive results. The addition of ExEcho data to a model based on clinical and ExECG data significantly increased the c statistic from 0.898 to 0.968 (change +0.070, 95% confidence interval 0.052-0.092), with a continuous net reclassification improvement of 1.56 and an integrated discrimination improvement of 22% (p<0.001). Decision curve analysis showed that a strategy of referral to coronary angiography based on ExEcho was associated with the highest net benefit and with the largest reduction in unnecessary coronary angiographies. CONCLUSION: ExEcho provides significant incremental prognostic information and higher net clinical benefit than a strategy based on ExECG in patients referred to a chest pain unit for suspected ACS and negative troponin levels.


Assuntos
Angina Instável/diagnóstico , Dor no Peito/etiologia , Doença da Artéria Coronariana/diagnóstico , Ecocardiografia , Eletrocardiografia , Teste de Esforço/métodos , Infarto do Miocárdio/diagnóstico , Idoso , Angiografia Coronária , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Curva ROC , Fatores de Risco , Troponina/sangue
18.
Eur Heart J Cardiovasc Imaging ; 16(11): 1207-12, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25851319

RESUMO

AIMS: Limited data are available regarding changes over time in referral patterns and outcomes of non-invasive cardiac stress testing. Our aim was to evaluate the temporal changes in the use and results of exercise echocardiography in our area of reference. METHODS AND RESULTS: A total of 12 339 patients referred to our unit for exercise echocardiography between 1997 and 2012 were included. We divided the 16-year period into four quadrennia and evaluated the changes in clinical data, results of the tests, referrals for invasive management and outcomes. We observed a gradual decrease in the frequency of detection of myocardial ischaemia from 35.3% in1997-2000 to 25.4% in 2009-12 (P < 0.001). There was also a progressive increase in the prevalence of cardiovascular risk factors and in the frequency of non-ischaemic chest pain and dyspnoea, while the proportion of patients with prior myocardial infarction and non-interpretable electrocardiograms declined. The rate of referral to coronary angiography within 6 months decreased from 24.8% in 1997-2000 to 19.6% in 2009-12 (P < 0.001), but the rate of coronary revascularization remained almost unchanged (13.1 to 11.7%, P for the trend = 0.16). We also observed a progressive decrease in the 1-year mortality rate from 3.4 to 1% (P < 0.001). CONCLUSION: Over a 16-year period, there was a gradual decrease in the frequency of myocardial ischaemia among patients referred to our unit for exercise echocardiography, which was parallel to changes in their clinical profile. However, this was not accompanied by a significant reduction in the rate of coronary revascularization.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Ecocardiografia sob Estresse , Idoso , Doenças Cardiovasculares/mortalidade , Comorbidade , Eletrocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
20.
J Thorac Cardiovasc Surg ; 148(6): 2845-53.e1, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25131169

RESUMO

OBJECTIVE: The present study aimed to identify potential differences in hemodynamic performance between the supra-annular CarboMedics Top Hat valve and the intra-annular CarboMedics standard valve in terms of the long-term left ventricular mass reduction and transvalvular gradients. METHODS: We retrospectively reviewed a series of 186 consecutive patients who had undergone aortic valve replacement with a small size mechanical prosthesis at our institution from 2003 to 2013, receiving either a CarboMedics Top Hat valve (53 patients, valve size, 21 mm in 52.8% and 23 mm in 47.2%) or a CarboMedics standard prosthesis (133 patients, valve size, 19 mm in 14.3% and 21 mm in 85.7%). RESULTS: The in-hospital mortality was 9.4% and 11.3% in the Top Hat and standard groups, respectively (P = .71). The mean percentage of left ventricular mass reduction was greater in the Top Hat group (33% ± 15.8% vs 20.1% ± 16.6%, P < .001). The mean postoperative peak aortic gradient was lower in the Top Hat group (19.9 ± 8.9 vs 29.6 ± 8.6 mm Hg; P < .001). Spearman analysis showed a positive correlation between the indexed effective orifice area and the percentage of left ventricular mass reduction (Rho = +0.65, P = .02). The survival in the Top Hat group was 79.7% and 71.7% at 5 and 10 years, respectively. In the standard group, survival was 66.8% and 61.5% at 5 and 10 years, respectively (log-rank test, 0.19). Cox regression demonstrated severe myocardial hypertrophy (hazard ratio, 2.559; 95% confidence interval, 1.095-5.981) as one of the independent predictors of survival. CONCLUSIONS: The Top Hat valve surpasses hemodynamically the intra-annular valve. We suggest the supra-annular Top Hat prosthesis can be especially recommended for patients with a small aortic root and severe myocardial hypertrophy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hipertrofia Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Distribuição de Qui-Quadrado , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Mortalidade Hospitalar , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/mortalidade , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...